Filter Results By:

Products

Applications

Manufacturers

Mains

chief conduit of electricity, gas or water distribution.


Showing results: 661 - 675 of 678 items found.

  • Geiger Counters

    PCE Instruments

    A geiger counter detects nuclear radiation by measuring the emission of ionizing radiation of alpha particles, beta particles and gamma rays. Also referred to as a radiation detector, a geiger counter consists of two main elements: the processing electronics and the geiger tube. The geiger tube is filled with low-pressure inert gas like helium, argon or neon. If radioactive radiation occurs, the inert gas is ionized. An anode within the geiger tube registers the quantity of ionized particles numerically correlating with the strength of the radioactive radiation. The radioactivity measurement is then displayed on the LCD screen of the geiger counter or radiation detector.It is very important to measure radioactivity as well as to classify radioactivity values. For example, terrestrial gamma radiation is measured according to general values from 0.03 - 0.3 µSv/h (microsievert / hour). This "normal" oscillation range is conditioned by natural radioactive elements in the ground such as uranium and potassium. To calculate this factor, one must take into consideration cosmic radiation. For example, when considering cosmic radiation, the maximum radioactivity content at Schneefernerhaus, the highest-located German environmental research station, is approximately equal to 110 µSv/h.At PCE Instruments, you will find three types of geiger counter or raditation detection devices to help you measure radioactivity: 1) alpha radioactivity meters, 2) meters for detecting alpha, beta and gamma radioactivity and 3) radioactivity meters for human beings.

  • Natural Cooling Input 380VAC 3 Phase to Output 190-300VDC 10A-40A Rectifier Battery Charger

    SD230D20ZZ - Zhejiang Sandi Electric Co., Ltd

    SANDI “SD” series intelligent high-frequency switch power supply modules are specially developed to meet the demands of modern DC system. The charger rectifiers are designed with world leading patent technology “resonant voltage type soft switching power supply technology”. They feature high efficiency and stability, intelligent control, small size and light weight. Standard RS-485 interface, easy to connect with automation system. “Four remotes” functions, intelligent management. The products are widely used in power plant, substations and etc..Main characteristic of the moduleModularization design, realize N+1 backup;The friendly man-machine interface. Large screen to show, realize man-machine dialogue operate really.RS-485 inrerface, realize “4 remote” function with monitor machine.High efficiency, Nearly 95%-96%;Lightly, 230V/10A natural cooling module only 9kg;Little volume, 230V/10A natural cooling module dimension only 325mm×230mm×130mm;After the full bridge rectifying circuit rectifies 3-phase AC to DC, then adjusted by reactive PFC, power factor>0.94;Function against reverse pour: each module has been added diode against reverse pour at output terminal.LED digital screen, digital calibrate, stable current ,fault alarm Main characteristic of the ModulesThe friendly man-machine interface. LED digital screen, digital calibrate, stable current ,fault alarmHigh efficiency, up to 95%-96%;Light weight, Small sizeAfter the full bridge rectifying circuit rectifies 3-phase AC to DC, then adjusted by reactive PFC, power factor>0.94;Unequal current ratio of parallel connection<+/-3%, can ensure twenty modules work well by parallel connection.Multiple protections including over/under voltage, current limiting, short-circuit, parallel protection, over-temperature protection.Output over-voltage protectionTo prevent the disastrous accident caused by output overvoltage, there is overvoltage protection circuit in the module. Once the output voltage is higher than the threshold, the module locks up automatically and fault indication light is on, the faulty module quits work automatically and doesn’t affect the normal operation of the entire system.Output current limiting protectThe output current cannot increase infinitely. The maximum value of the output current of each module is limited to the rated output current 105%, in this range, the output current value of the module is continuously adjustable. If the load output of the module, the module will play down the output voltage.Output short-circuit protectionWhen short circuit, the output voltage drops to 0 immediately. Limit the short circuit current under 15% of rated output current. The module will not be damaged under short circuit state for a time, and resumes to work automatically after debugging. Module parallel protectionThere is parallel protection circuit in each module to ensure that when the fault module quits the system, the normal work of other modules and the system won’t be effect.Output over-current protectionThe output current cannot increase infinitely. If overloaded, the output voltage decreases automatically to protect the power components. The over current protection can be resumed automatically.

  • Circuit Breaker Analyzers & Timers

    CAT Handheld Series - IBEKO Power AB

    When it’s not practical to use conventional robust circuit breaker analyzers, a handheld circuit breaker analyzer and timer may come handy. DV Power has developed a unique CAT Handheld series. It is specially designed for testing of circuit breakers with one break per phase. Their compact and ergonomic design can provide a wide range of features and reliable operations in low, medium and high-voltage substations or in industrial environments.CAT Handheld series consists of two models, CAT-P and CAT-H. Both of them have a large (5,7 in) colored touch screen display. Because of that, test results are visible in dark places as well as in bright sunlight.Powerful internal Li-Ion battery of the instruments can last up to 8 hours of testing without recharging.CAT Handheld series records:main contacts operating times,contact synchronization,sequence time,a resistance of pre-insertion resistors,open and close coil currents,main contacts bounce time,auxiliary contact time,DC Voltage.Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by triggering signal from current clamps connected to circuit breaker coil.CAT-H is capable of performing a coil control, while this feature is optional at CAT-P instrument. In contrast to CAT-H, CAT-P instrument can execute “First Trip” test.Both instruments display numerical and graphical results. Because of that, a user can easily overlay up to 4 records in the graphical form and make a quick on-site analysis of potential defects.A user can download test results to a PC via Bluetooth interface for more detailed analysis using DV Win software.

  • Tes Rreceiver

    KH3932 - Beijing KeHuan Century EMC Technology Co,.LTD

    The KH3932 EM1 test receiver is a fully automatic test receiver and the main tool for EM1 testing. The frequency range of the KH3932 receiver is from 9kHz to 300MHz. Equipped with a power absorption clamp, it can meet the power line disturbance power test. After the artificial power network is configured, the power terminal disturbance voltage test can be carried out. The machine has fast test speed and maneuverability. Strong, stable performance, convenient test data processing and other advantages. The KH3932 receiver uses the USB interface to exchange data with the computer, which makes the transmission speed fast and the bit error rate low. Connect to the computer for testing and use the operating environment familiar to the operator to improve work efficiency.The equipped operating software saves the data of a variety of external equipment, and supports plug and play a variety of external test equipment. The software and hardware are developed by our company. The whole machine uses a fully enclosed structure, and the chassis uses highly conductive materials with good shielding effects. Due to the use of specific technologies and processes, the problem of its own resistance is fundamentally solved. The measurement results are in the international general report format, which can be saved in the computer's hard disk or transmitted through the network, printed out directly, and saved using a USB storage device. The report is rich in content and can be printed directly according to user needs without additional editing.The measurement receiver complies with the requirements of the national standard GBT6113.101 and the international standard CISPR16-1.

  • Ultrasonic Flaw Detector

    MFD660C - Mitech Co., LTD.

    MFD660C intelligent digital ultrasonic flaw detector, Mitech concentrated years meticulously developed premium product, has a lot of advantages like unique design, sophisticated manufacturing, convenient operation, powerful function. It had received customers' favored since its inception. It can test, orient, evaluate and diagnose various flaws such as crack, lard, air hole in workpiece’s interior swiftly and accurately without any destruction. With full digital 640X480 TFT LCD display, it can select the operating interface style and the LCD brightness according to environment. With humanizing interface design, the waveform show delicately. It can find the defects clearly in full screen. Single hand capable for holding operation, the curve making, probe calibration and other conventional operation can be completed automatically. Core processor CPU with 400M main frequency, it can complete the complex run quickly and realize intelligent defect analysis. Low power design with large capacity and high performance lithium ion battery module, it can work more than 10 hours continuously. Full English master-slave menu, emphasizing on user experience, collecting shortcut keys, digital shuttle rotary wheel, cross menu three operating ways in one body, customers with different habits can operate it freely. It supports many languages. Its waterproof, oil proof, dustproof function can achieve IP65 protection level. It is the necessary professional precision instrument for defect detection, quality control, on-line safety monitoring and life evaluation in fields of oil, chemical, metallurgy, shipbuilding, aviation, railways and so on.

  • Enlarge Environmental Chamber

    REXMED REC-450 - REXMED Industries Co., Ltd.

    MOD. REC-450, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,644 Watts, 12,433 BTU/hr, 3,140 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-250 - REXMED Industries Co., Ltd.

    MOD. REC-250, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-400 - REXMED Industries Co., Ltd.

    MOD. REC-400, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,506 Watts, 11,962 BTU/hr, 3,020 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-280 - REXMED Industries Co., Ltd.

    MOD. REC-280, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-480 - REXMED Industries Co., Ltd.

    MOD. REC-480, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 5,270 Watts, 18,000 BTU/hr, 4,545 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-200 - REXMED Industries Co., Ltd.

    MOD. REC-200, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 1,892 Watts, 6,455 BTU/hr, 1,630 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Rugged, Long Gauge Length Extensometers

    Model 3543 - Jinan Testing Equipment IE Corporation

    With over 15 years of proven reliability in the world’s most demanding testing environments, the Model 3543 extensometer is designed to survive in those applications where standard axial extensometers would not. Designed by Epsilon, the Model 3543 was created to survive specimen failure by separating into two halves, thus preventing permanent damage to the module body. During operation, the upper half of the extensometer pulls out of the main body. Tapered measuring beams activate strain gaged flexures within the unit. This unique design allows long measuring ranges, yet retains compatibility with electronics for strain gaged transducers. These models offer high accuracy and are light weight but rugged, with low operating force. They are tension only units.The units have hardened tool steel knife edges. Standard quick attach wires provided with the extensometer work on flat specimens up to 12 x 31 mm (0.5 x 1.25 inch) and on rounds up to 25 mm (1 inch) diameter. Optional quick attach kit wire forms are available for use on larger samples. See Model 3542L for long gauge lengths with smaller measuring ranges.The Model 3543 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.

  • Circuit Breaker Analyzers & Timers

    CAT Advanced Series - IBEKO Power AB

    DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.

  • Circuit Breaker Analyzers & Timers

    CAT Standard Series - IBEKO Power AB

    Circuit breakers are being tested during manufacturing, commissioning or maintenance stages. The most basic test requires timing measurement using circuit breaker timer. Their primary role is timing and motion measurement of medium and high voltage circuit breakers. Devices from CAT Standard series have suitable application in:electric power generation,distribution system,part of the electric power transmission system,contractors testing,and industrial environments.CAT Standard series meets the requirements of an easy to use circuit breaker timer and analyzer with an attractive price. Furthermore, they are portable and lightweight (weighs only up to 7 kg). Finally, the plastic case is unbreakable and has IP67 protective rating when the lid is closed.CAT Standard series includes five models:Three circuit breaker timers – CAT03, CAT31, and CAT61Two circuit breaker analyzers – CAT34 and CAT64CAT03 is a basic model intended only for timing measurement of main contact operations on the circuit breaker with one break per phase. Unlike CAT03, CAT31 has the possibility of circuit breaker operation initiation, coil current measurement, and auxiliary contact timing measurement. CAT61 differs in comparison to CAT31 by its ability to measure up to two breaks per phase.CAT34 and CAT64 are more advanced compared to CAT31 and CAT61, respectively, since they have additional analog channels. Also, they have the possibility of a travel curve recording.A user can download the test results to a USB memory stick or save it to internal memory. The CAT Standard series internal memory can store up to 500 test results (numerical and graphical data). Optional thermal printer prints test results in tabular and graphical form on 80 mm (3.15 inch) paper rolls. CAT Standard series instruments are compatible with DV-Win software. It provides full control of all CAT functions from a PC, as well as acquisition and analysis of test results.

  • DataLogger

    Hastest Solutions Inc.

    Memory capacity is 8100 lines of data per channel. (It is possible to store the data for about 506 days with log interval of 90 minutes.)The method of storing data can be selectable among four logging options. (Once, Repeatability, Ends at, By page)The date and time to start logging automatically can be specified by setting the preset start.The measurement data can be transmitted in realtime to a personal computer.USB transmission is adopted.The upper and lower thresholds for warning can be set. When the temperature or humidity threshold is triggered, the alarm mark (Hi or Lo) will light.Display Functions: TIME (display time), INT (log interval) REC (during logging). RES (during preset standby), OUT (during real-time tranmission), LCD bars (used memory) CALL (call for the current measurement data during logging) Current temperature, Current humidity, Current date and time, low battery mark, Temp. upper limit (Hi), Temp. lower limit (Lo), Humi. upper limit (Hi), Humi. lower limit (Lo), Temp. alarm ON (Alarm), Humi. alarm ON (Alarm), logging option, setting value of upper and lower limits. errer message, ID numberProbes are interchangeably used with main units.The storage memory can be varified with the memory indicator.The log interval can be selected from 14 options: 1 sec, 2 sec, 5 sec, 10 sec, 15 sec, 30 sec, 1 min, 2 min, 5 min, 10 min, 15 min, 30 min, 60 min. and 90 min.When the power is turned off, data stored in the EEPROM memory is retained.The datalogger ID can be set. This is useful to identify multiple dataloggers.By using data analysis software attached, acquired data can be evaluated easily and quickly, and also evaluated by using commercial spreadsheet software supporting the "CSV" extension such as Lotus 1-2-3 and Microsoft Excel.Software for data analysis and realtime transmission (CD-Rom)

Get Help