Showing results: 721 - 735 of 2290 items found.
-
LQ404 -
Computer Gesteuerte Systeme GmbH
The qualification tester LQ402 is designed to support up to 12 DUTs (Device under Test), for which the loads are installed in separate load boxes. The system consists out of 3 cabinets. One is for the electronic components with the primary measurement devices and the other two hold the 12 load boxes.
-
LQ402 -
Computer Gesteuerte Systeme GmbH
The qualification tester LQ402 is designed to support up to 6 DUTs (Device under Test), for which the loads are installed in separate load boxes. The system consists out of 2 cabinets. One is for the electronic components with the primary measurement devices and the other one holds the 6 load boxes.
-
AW Dynamometer, Inc.
AW is the world leader in AG/PTO dynamometers with over 14,000 units sold. AW's hydraulic activated load unit is water cooled allowing it to test high torque loads for continuous periods of time. AW's heavy duty load units are well known to last for decades. Combine this with all new computerized electronic load control, software, thermocouples, sensors and you have a system second to none - the AG.X Series.
-
Series DH -
Teledyne Relays
Series DH relays are designed for all types of loads. These relays feature our new high efficiency back-to-back thyristors for long lifetime expectancy. The relays utilize optical isolation to protect the control from load transients. All relays offer a green control LED and Zero-Cross switching.Available options include:DH24D25 25A, 12-280Vrms, 600Vpeak Load; 3-32Vdc ControlDH24D35 35A, 12-280Vrms, 1200Vpeak Load; 3-32Vdc Control
-
515 -
Clarke-Hess Communications Research
The Model 515 High Accuracy AC Reference Generator fills a need for a relatively low cost and practical solution for supplying a reference excitation to typical LVDT and Synchro/Resolver transducers. The Model 515 has built-in load sensing which, in effect, yields "zero" output impedance and virtually eliminates the effects of fluctuating output loads. With up to 15 VA of output into loads with as much as 80 of phase shift, the Model 515 is ideally suited to driving inductive loads.
-
Series CD -
Teledyne Relays
The CD series Solid-state Relay utilizes the latest technology to provide a low ON resistance. The control circuit is buffered to enable the relay to be driven directly from standard CMOS or open collector TTL logic circuits. Available options include short circuit protection and current overload protection or a status output line.MSL 1CD relays are controlled by 3.8-6VdcC = Through-hole mount SC = Surface mountAvailable options include:CD00CF 2A, 60Vdc LoadSCD00CF 2A, 60Vdc LoadCD01CF 2A, 60Vdc Load; control statusSCD01CF 2A, 60Vdc Load; control statusCD20CD 1A, 60Vdc Load; short-circuit protectionSCD20CD 1A, 60Vdc Load; short circuit protectionCD21CD 1A, 60Vdc Load; short-circuit protection & control statusSCD21CD 1A, 60Vdc Load; short circuit protection & control status
-
spriteCloud
spriteCloud is a Load & Performance test specialist and an authorised Loadstorm partner.We can build scenarios, run load tests and analyse results to help our customers support their questions in this field.
-
61-164 -
IDEAL Industries, Inc.
*Measures voltage drop under load**Hot and neutral conductor impedances*Estimates Load on Line (ELL) up to 15A*Tests GFCIs and EPDs for proper operation*Super-bright OLED display*High accuracies*True RMS*Line and peak voltage*Identifies proper wiring in 3-wire receptacles*Identifies false (bootleg) grounds*Tests without disturbing sensitive loads*Verifies isolated grounds (with 61-176 adapter)*2-year warranty*12A, 15A, 20A load tests
-
PTR1102 -
Rhesca Co., Ltd.
In wire bonding in semiconductor manufacturing, electrodes are joined using gold wires of several tens of microns. In order to measure the pull (tensile) strength and ball shear (shear) strength of this gold wire, this machine has load detection accuracy and fine positioning accuracy. In addition, for the measurement of high load areas such as die shear strength and solder joint strength, this machine supports measurement in high load areas while maintaining accuracy in low load areas by replacing the sensor part.
-
Series SQ -
Teledyne Relays
Series SQ relay provides four independent 25A relays in a standard hockey-puck package. The SQ package conserves space while providing high-power switching. The tight zero-cross window reduces the EMI level. Optical isolation ensures complete protection of the control circuit from load transients.Available options include:SQ24D25 25Arms, 12-280Vrms, 600Vpeak Load; 3-32Vdc Control; Zero-CrossSQ24R25 25Arms, 12-280Vrms, 600Vpeak Load; 4-30Vdc Control; RandomSQ24R25-02 25Arms, 12-280Vrms, 600Vpeak Load; 3-32Vdc Control; Zero-Cross
-
Maury Microwave Corporation
Manual tuners are used both in the laboratory and as system components to establish or transform impedances for a number of applications. They can be used to establish optimum source or load terminations for device characterization, normalize a source or load for precision laboratory measurements and/or calibrations (noise, power, etc.), and can act as a matching transformer between a mismatched source and a mismatched load.
-
MS-ZH Series -
Newage Testing Instruments, Inc.
The MS-ZH Microhardness Testing System provides accurate loads using dead weight and automated switching between each of the testers nine test loads from 10 to 2000 grams.
-
-
-