Filter Results By:

Products

Applications

Manufacturers

Loads

test full state.

See Also: Load Boards


Showing results: 721 - 735 of 2327 items found.

  • Dual-Phase Relays

    Series SD - Teledyne Defense Electronics Relays & Coax Switch

    Series SD dual-phase relays are designed for all types of loads. The design incorporates two relays in a single package. The relays utilize optical isolation to protect the control from load transients. High-current models are excellent for motor and phase angle control. SD relays are available with faston or screw terminals, and Zero-Cross or Random switching.-06 = Faston Terminals​Available options include:SD24R50 ​ 50Arms, 12-280Vrms, 600Vpeak Load; 4-30Vdc Control; RandomSD24D40-06 ​ 40Arms, 12-280Vrms, 600Vpeak Load; 4-30Vdc Control; Zero-CrossSD24D50-06​ 50Arms, 12-280Vrms, 600Vpeak Load; 4-30Vdc Control; Zero-CrossSD24R50-06​ 50Arms, 12-280Vrms, 600Vpeak Load; 4-30Vdc Control; RandomSD48D50A​ 50Arms, 24-600Vrms, 1200Vpeak Load; 10-30Vdc Control; Zero-CrossSD48D50A​2 50Arms, 24-600Vrms, 1200Vpeak Load; 10-30Vdc Control; Zero-CrossSD48D40-06​ 40Arms, 24-600Vrms, 1200Vpeak Load; 5-30Vdc Control; Zero-Cross

  • Single Phase AC Relays - Delivering Output to 75A, 600Vac

    Series STH - Teledyne Defense Electronics Relays & Coax Switch

    Series STH relays offer high performance in a flexible and innovative package. Designed for all types of loads, they deliver output to 75A, 600Vac for resistive loads. They have removable touch-proof terminal covers for versatile, easy, and quick connections. STH relays feature a metal base-plate and are up to 30% lighter than standard relays, and are Zero-Cross switching.Available options include:STH24D12 12A, 12-280Vac, 600Vpeak Load; 3-32Vdc ControlSTH24D25 25A, 12-280Vac, 600Vpeak Load; 3-32Vdc ControlSTH24D35 35A, 12-280Vac, 600Vpeak Load; 3-32Vdc ControlSTH48D50 50A, 24-600Vac, 1200Vpeak Load; 3-32Vdc ControlSTH24D50 50A, 12-280Vac, 600Vpeak Load; 3-32Vdc Control

  • Single Phase AC ISSRs

    Series SH /AC - Teledyne Defense Electronics Relays & Coax Switch

    Series SH relays offer high performance in a flexible and innovative package. Designed for all types of loads, they provide output to 125A, 690Vac. They incorporate removable touch-proof terminal covers for versatile, easy, and quick connections. SH relays feature a metal base plate and built-in LED, and are up to 30% lighter than standard relays. Zero-Cross and Random switching options available.Available options include:SH24D25 25A, 12-275Vac, 600Vpeak Load; 3-32Vdc Control; Zero-CrossSH24A25 25A, 12-275Vac, 600Vpeak Load; 20-265Vac/Vdc Control; Zero-Cross​SH48D35 35A, 12-510Vac, 1200Vpeak Load; 3.5-32Vdc Control; Zero-Cross​​SH48A50 50A, 12-510Vac, 1200Vpeak Load; 20-265Vac/Vdc Control; Zero-Cross​SH48D95​ 95A, 12-510Vac, 1200Vpeak Load; 3.5​-32Vdc Control; Zero-Cross​​SH48A95 95A, 12-510Vac, 1200Vpeak Load; 20-265Vac/Vdc Control; Zero-Cross​SH48R125 125A, 12-510Vac, 1200Vpeak Load; 3.5-32Vdc Control; RandomSH48D125 125A, 12-510Vac, 1200Vpeak Load; 3.5-32Vdc Control; Zero-Cross​SH48A125​ 125A, 12-510Vac, 1200Vpeak Load; 20-265Vac/Vdc Control; Zero-Cross​SH60D50 50A, 12-510Vac, 1600Vpeak Load; 3.5-32Vdc Control; Zero-Cross​SH60D125​ 125A, 24-690Vac, 1600Vpeak Load; 3.5-32Vdc Control; Zero-Cross

  • Dynamic Jack System

    Shimadzu Corp.

    This is a structural fatigue testing machine for researching the dynamic behavior of full-size or model structures by applying repeated loads. The actuator that supplies the loads to the specimens can be installed on load frames, reaction floors, reaction walls, etc.

  • Multifunction Power Meter

    PowerLogic ION7300 series - Schneider Electric SA

    Highly-configurable meters for feeders or critical loads. Compact energy and power quality meters for feeders or critical loads.

  • Arbitrary Load-Impedance X-Parameters

    S94520B - Keysight Technologies

    S94520B Arbitrary Load Impedance X-parameters enables an X-parameter model to be collected over a user defined set of load impedances. S94520B still requires an application to control the load impedance such as S94521B or Maury ATS or IV Cad.

  • Advanced Measurement and Modeling Software

    IVCAD MT930 Series - Maury Microwave Corporation

    IVCAD advanced measurement and modeling software, offered by Maury Microwave and AMCAD Engineering supports multiple load pull techniques including traditional load pull using external instrumentation, VNA-based load pull, active load pull and hybrid load pull. It performs DC-IV and pulsed-IV measurements and incorporates device modeling tools. Its modern visualization capabilities give users a greater ability to view, plot and graph measurement data in an intuitive manner.

  • Break Strength Testing

    National Technical Systems

    To determine the failure point or break strength, you will need to define what a break is (break detector). Generally, there are two common types of breaks: the sharp break is referred to the measurement when load or force drops by 5% from its peak load measurement. A percentage break is another form of break and is generally determined by the sample material and its relationship to load degradation from a peak load measurement. A plastic material will likely have a load drop of 5%, but not represent a break. In this case, a percentage break would need to be applied. In a tensile test, the breaking load is the break strength.

  • Medium Power-Load Relays

    Series G - Teledyne Defense Electronics Relays & Coax Switch

    Series G relays are designed for medium-power loads. The design incorporates a thyristor output. Series G relays utilize optical isolation to protect the control from load transients. An internal MOV is also provided to protect against load transient voltages. The compact size makes it ideal for designs where space is limited.​ Zero-Cross and Random switching options available.Available options include:G24R12-06 12Arms, 12-320Vrms, 520Vpeak Load; 3-32Vdc Control; RandomG24D12-06 12Arms, 12-320Vrms, 520Vpeak Load; 3-32Vdc Control; Zero-Cross

  • Electronic Loads/Sinks

    LXinstruments GmbH

    An electronic load offers the possibility of testing the specimen under different loads. Various load changes are simulated, as they can occur in normal operation. For this purpose, the relevant load current is set in a defined range and electronically controlled. For the test, different operating states are either programmed or entered into the system via an interface (USB, RS-232, GPIB...). For easy handling and quick use, there are four operating modes.

  • Meter Box Series

    Shenzhen Star Instrument Co., Ltd.

    The single-slot meter box for single-phase DIN rail energy meters has a window for load switch control if a load switch is installed.

  • Current Meters

    Holding Informtest

    Measure current using either "Average responding" meters reading linear loads or "True RMS" meters measuring non linear loads.

  • Subsea Tensile Link

    SUBT-3.0 - Dynamic Load Monitoring Ltd.

    The Subsea Tensile Link is specially designed for working in subsea conditions and is used for measuring tensile loads. With an optional integral 4-20mA amplifier the load cell is packaged in a wooden case with a subsea rated signal cable to customer specific lengths or alternatively can be supplied with a TW-3.0-S display. Fully sealed with a subsea connector and pressure tested to over 250Bar the load cell is the ideal instrument for easily and accurately measuring subsea loads.

  • Dual Channel Clock Driver Card

    PI-41400 - Pulse Instruments

    The PI-41400 is a dual channel Clock Driver card capable of operating up to 190 MHz into a 50-ohm load and up to 80 MHz at an amplitude of 8 volts into a 1-megohm load. Into a high impedance load the output voltage range is from a –3 volts to 8 volts with the output pulse amplitude ranging from 0.5 V to 9 V. When driving a 50 load the voltage range is –1.5 volts to 4.5 volts with the output pulse amplitude ranging from 0.25 V to 4.5 V. The rise and fall times of the output pulse are variable from 1.2 ns to 9 ns into a 50-ohm load and <5 ns to 9 ns into a HiZ load. The output pulse amplitude and the load being driven determine the range of variability. The driver output can be set for tri-state operation and the output polarity can be set for ‘Normal’ or ‘Inverted’ operation through software.

  • Qualification Tester

    LQ404 - Computer Gesteuerte Systeme GmbH

    The qualification tester LQ402 is designed to support up to 12 DUTs (Device under Test), for which the loads are installed in separate load boxes. The system consists out of 3 cabinets. One is for the electronic components with the primary measurement devices and the other two hold the 12 load boxes.

Get Help