  • PXIe-8234, GigE Vision PXI Frame Grabber Module

    780263-01 - NI

    GigE Vision PXI Frame Grabber Module—The PXIe-8234 with Vision Acquisition Software can acquire images from the fastest GigE Vision cameras. It transfers images at full Gigabit Ethernet bandwidth on both ports simultaneously, and it is optimized for extremely low CPU load. The PXIe-8234 with Vision Acquisition Software provides full GigE Vision bandwidth at every port, giving you the bandwidth you need for your most demanding vision applications. It also includes NI Vision Acquisition Software, which is driver software for acquiring, displaying, logging, and monitoring images from a multitude of camera types. With a set of easy-to-use functions and example programs, you can quickly create applications using LabVIEW, C, C++, C#, Visual Basic, and Visual Basic .NET.

  • 100KW AC/DC Rectifier Battery Charger Customized for Lead Acid Gel LiFePO4 Lithium Battery converter

    SD750250G - Zhejiang Sandi Electric Co., Ltd

    AC-DC Power Rectifier Battery Charger Customized for Lead Acid AGM Gel LiFePO4 Lithium Battery is for DC battery system charging station. With single-phase or 3 phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. 50-750Vdc output voltage range optional, suitable for all types of batteries.Product Introduction:SAND AC/DC Charger is specially developed for DC chargers module. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase or single phase, DC output voltage range from 50 to 750VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger module.Unique function:● High efficiency over the full load range, full load efficiency greater than 95.5%● Wide output voltage range, 50-750VDC, suitable for a wide range of Lithium and lead acid battery● 5-inch LCD touch screen, easy to operate● Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operateMain features:● Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.● Three phase active power factor correction technology, reduces the harmonic interference to the grid● Dual DSP design, achieve the full digital control, less components means high reliability● Wide input voltage range, allows operation in most poor grid conditions● Soft start charging and soft shutdown minimize the impact on the battery.● Input, output have protective circuit breaker switch● Module adopts hot pluggable design, which is convenient for maintenance.● CAN/RS485 interfaceSpecificationModel SD750250GAC input Input system Three phases + PEVoltage range 340Vac ~450VacRated voltage 400VacFrequency range 50Hz/60HzMaximum current <192AITHD (total harmonic distortion) <5%DC output Voltage range 100-750Vdc ( can set)MAX. Output current (A) 250ACurrent range 1 ~ 250A (can set)Steady voltage precision <±0.5%Steady current precision ≤±1% (rated range of 20% ~ 100% for output load)Load regulation rate ≤±0.5%Startup overshoot ≤±3%Peak-to-peak value noise ≤1% (200~1000V, 0~20MHz)Display Indication Light Green LED: normal operation,Yellow LED: alarm, Red LED: failureDisplay language EnglishDisplay 5’ LCD touch screenPower factor and THD Power factor ≥0.90 Full-load output power of @20%~50%≥0.98 Full-load output power of @50%~100%≥0.99 Full-load output power, input nominal voltage and frequency of @100%THD ≤5% Full-load output power of @50%~100%Protection function input overvoltage Protection Over Under Voltage automatic shutdown and restart when voltage return normalOutput overvoltage protection Over Under Voltage automatic shutdown and restart when voltage return normalOver-temperature protection Automatic shutdown. Automatic restart when the temperature return to normalShort circuit protection Automatic shutdown and lock, need power off to restart to unlockEfficiency Under Rated input voltage ≥95.2%Application place Indoor (IP20)Environmental conditions Operation temperature -20°C ~ +75°C, derating from 55°CStorage temperature -40°C ~ +70°CRelative humidity ≤95%RH, without condensationCooling mode Forced fan coolingNoise ≤60dB (1m away)Altitude 2,000mCommunication RS485 / CAN BUSInsulation resistance insulation resistance of DC and AC part to housing and the AC to the DC part shall be ≥ 10MΩ

  • On-line UPS, Rackmount & Tower 700VA To 3kVA

    SC Series - Falcon Electric, Inc

    *Reliable, online UPS. When deciding on a UPS solution, be aware of the UPS type. The SC is an online UPS, meaning its inverter is always “on” to provide new, clean AC power.*User-friendly LCD display. The SC UPS has an easy-to-use display for quick access to UPS status, battery and load levels – and more.*Advanced communications. The supplied software supports unattended shutdown and UPS management. An optional SNMP/HTTP agent board is available.*Rack/Tower configuration. Simply rotate the LCD display on a rackmount model to use as a tower UPS.*User-programmable frequency converter. The SC UPS is easily programmable as a 50 or 60 Hz frequency converter.*Falcon is recognized for quality and reliability. Falcon Electric is a leading manufacturer of reliable online UPS for over 30 years. Our technical expertise assures you find the right solution – the first time.

  • Compact Automatic Voltage Regulating Relay With Built- In TPI

    Neutronics Manufacturing Co.

    NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.

  • Compact Automatic Voltage Regulating Relays

    Neutronics Manufacturing Co.

    NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.

  • Computery Control Torsion Tester

    SG-L10 - Jinge Testing Machine Co.,Ltd

    The machine is mainly used for torsion test of metal and nonmetal,also it is applicable to the torsion test of parts and members. Servo-motor and cycloid gear reducer are introduced to the loading system in this product, the system for measuring torque and distortion angle are composed of high accurate torsion sensor, photoelectric encoder and computer measuring force.It possesses automatically tracking test torque and distortion angle, maintaining maximum peak load and displaying loading speed.Test data automatically display and process, print the test report according with the national criterions, including test date, number, material quality and torsion strength etc. The machine characterizes advanced technology, high accuracy, good stability, reliable quality and easy to operate, and it is necessary test instrument for aeronautics & astronautics, construction material, traffic, wire & cable, science research departm ent and universities.

  • Automatic Voltage Regulating Relay- Standard Model

    Neutronics Manufacturing Co.

    NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.

  • Battery Capacity Testers|Discharge Testers

    IBEKO Power AB

    DV Power offers a wide range of battery capacity testers to meet specific customer needs. All of them are portable, powerful and most of all universal. Any battery string, such as lead-acid, lithium-ion, nickel-cadmium based and others, with voltages in the range of 0,9 – 800 V DC can be tested in an accurate, user-friendly way.The capacity test is carried out following the battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.BLU battery testers enable setting the discharge current up to 350 A, with 0,1 A resolution. If higher currents are required, several units can be connected in parallel, or BXL additional load units can be used. Discharge parameters can be monitored in real-time during the capacity test. Overall battery voltage, current, elapsed test time and capacity will be presented during the entire test on a touch screen display.

  • Battery Loading Unit

    BLUe - Scope T&M Pvt, Ltd.

    BLUe series Battery Loading Units; portable instruments for controlled & monitored discharge of batteries. It is designed for integrated site discharge test, design & QC test and also for monitoring discharge process of battery bank with connected load. Single autonomous unit having inbuilt display, keypad and wireless communication with PC makes it very easy to use. It comes in different configurations ranging from 12V to 380V discharge voltages and 50A to 300A discharge currents. Various options are available to control & monitor the discharge process. With the help of optional Cell Monitoring Unit - CELLMon, voltage of each individual cell can be monitored & data sent to main BLUe unit and then from main unit to PC via wireless communication. Each BLUe unit is supplied with PC downloading & analysis software for real time monitoring of discharge process.

  • Modbus Register Converter

    Model 2390 - ICS Electronics

    * Converts Modbus Registers and variables for replacement Modbus devices.* Maintain existing software when upgrading Modbus systems.* Provides serial control of Modbus RTU devices from any ASCII source.* User defined Register Conversion Table supports all Modbus RTU devices.* Internal Register Conversion Tables for Watlow F4-to-EZ-ZONE and F4-to-F4T conversion.* Serial ports support RS-232 and 2-wire/4-wire RS-485 signals.* Includes baud rate conversion capability.* Uses SCPI commands to load the Conversion Table and set serial settings.* Small metal case mounts on a DIN rail or on any flat panel.* 239x Table Loader Program uploads the 2390 Register Conversion Table from an Excel csv file.* 239x Serial Keyboard Program provides instant control of the 2390 and Modbus Slave Devices without writing a program.

  • AC Power Source

    9420 - NH Research, Inc.

    AC Source with HiVAR Technology Ideal for ATE use in Aviation, Aerospace, Defense, Military/Mission Critical Testing, Manufacturing Test, Research & Development & More! The Model 9420 AC Power Source redefines selection of an AC Source by addressing how to compensate for reactive power from capacitive or inductive elements in the load. Often overlooked when sizing a source, reactive power negates some portion of nominal VA power in order to arrive at true power (Watts) that does the real work. Traditional AC sources list only their VA rating leaving it up to the user to figure out how much true power remains after reactive power reductions. In many cases that reduction is substantial and then requires selecting a much larger VA-rated source than originally anticipated. The increased cost and size penalties are often considerable.

  • Electric Vehicle Service Equipment Test System

    T4350 - The Eastern Specialty Company

    With the growing demand for electric vehicles (EV), there needs to be a simple and accurate method to test EV charging systems. Test the accuracy of AC and DC voltages and currents with TESCO’s Electric Vehicle Service Equipment (EVSE) Test System TS400.  The TS400 is a valuable set with complete testing capabilities and caters to every possible EVSE charging protocol in the world (AC and DC). EV charging stations are popping up all over as the sale of electric vehicles increase.  Many states or counties are now mandating testing for these charging stations.  TESCO’s TS400 makes testing these chargers easy! TESCO’s EVSE Test Systems test the accuracy of energy delivery using a transactional mode compatible with Handbook 44 provisions. The TS400 Test System includes a T4000 EVSE Tester and a PL4000 EV Load Emulator. Reach out to your TESCO Representative for more information!

  • PXIe-4137, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit

    783761-01 - NI

    PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4137 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4137 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.

  • PXIe-4135, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit

    783762-01 - NI

    PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit - The PXIe-4135 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology and native triaxial connectors help you perform high-precision measurements with a current resolution of 10 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4135 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.

  • PXIe-4135, PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit

    783762-02 - NI

    PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit - The PXIe-4135 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology and native triaxial connectors help you perform high-precision measurements with a current resolution of 10 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4135 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.