Showing results: 1696 - 1710 of 2342 items found.
-
P845 -
Whitman Controls
The Whitman Controls P845 Differential Pressure Switches are rugged and versatile, with excellent by-pass characteristics and the ability to handle a wide variety of media to 6,000 PSIG and set point ranges to 250 PSID. These switches are NEMA 4 rated and can tolerate submersion. They are commonly used across oil and water filter heads to detect when a filter element needs changing. It may be mounted in any orientation and is capable of carrying light to moderate mechanical shock and vibratory loads.
-
Nippen Electrical Instruments Co.
DIGITAL METERS NIPPEN electronic energy meters are panel mounting type innovative energy monitoring devices ,having state of the art electronic microcontroller circuitry for reliability and accuracy. They can be used for 1Ø / 3Ø balanced and unbalanced loads.
-
Nippen Electrical Instruments Co.
DIGITAL METERS NIPPEN electronic energy meters are panel mounting type innovative energy monitoring devices ,having state of the art electronic microcontroller circuitry for reliability and accuracy. They can be used for 1Ø / 3Ø balanced and unbalanced loads.
-
Extech Instruments Corporation
Circuit and wiring issues can introduce shock hazards (from grounding issues) and can compromise performance of machinery and equipment (from poor ground impedance, lack of sufficient voltage under load and/or high ground-to-neutral voltage).
-
CS2-SG -
Chuan Sheng Electronics Co., Ltd.
CS2-SG Strain Gauge Indicator has been designed with high accuracy measurement, display and communication of DC signal 0~1.0/~4.0mV or 0~10.0/~40.0mV as like as Load Cell or Strain Gauge.The meter supports Field Calibration function. It can be calibrated with sensor(Load Cell/Strain Gauge) to meet machinery structure.They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS-485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of machinery and testing equipments applications.
-
CS3-SG -
Chuan Sheng Electronics Co., Ltd.
CS3-SG Strain Gauge Indicator has been designed with high accuracy measurement, display and communication of DC signal 0~1.0/~4.0mV or 0~10.0/~40.0mV as like as Load Cell or Strain Gauge.The meter supports Field Calibration function. It can be calibrated with sensor(Load Cell/Strain Gauge) to meet machinery structure.They are also building in 2 Relay outputs, 1 External Control Input, 1 Analogue output or 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of machinery and testing equipments applications.
-
RDS -
M.E.A. Testing Systems Ltd.
The principle of the test is to use a dynamic adjustable load with a servomotor that functions as a LOAD to the motor under test. The servo drive is fed through KEB R6 (regenerative unit).In our test bench, the loading motor operates as a generator. Historically, the regenerative energy was wasted into heat using resistors batteries. The MEA Regenerative Dynamometer System solution is to return the energy back into the main line power supply, eliminating heat and ultimately providing a real return on investment for the owner/operator of the system.This is particularly useful in all applications where prolonged or continuous downward motion occurs, or heat dissipation to the surrounding environment is not wanted.
-
AMM-1 -
D'Amore Engineering llc
The purpose of this tool is to enable the user to: Measure True Amplifier Power output into any load reactive or resistive Measure Common DC voltages Measure DC voltage drops during quick transients on cable runs or battery / charging systems Measure Impedance of speakers at any power or frequency from 20Hz - 1kHz (box rise) Measure Phase Difference between Voltage and Current into reactive loads (Power Factor) Find Tuning Frequency of subwoofer enclosures Tune subwoofer enclosures for maximum power transfer Measure AC Volts (amplifier output) Measure AC Amps (amplifier output)
-
Panasonic Industrial Devices Sales Company of America
High voltage and high current control for DC loads. Applications include: Battery Testing Equipment, Cogeneration Systems, Construction Machinery, Automatic Guided Vehicles, Welding Equipment, Inverter Control, Solar Power Generations Systems and Elevators.
-
MCH Instruments Co.,Ltd.
Digital Signal Generator*signal frequency:0.1Hz~2MHz, continuously variableave from: square, sine*output attenuator: 0dB,, 20dB, 40dB, 60dB*output level: 20Vp-p in open circuit, not less than 10Vp-p with 50Ω load*rising and falling edge of square not more than 35ns,*sine distortion less than 1%, amplitude –frequency characteristic : ±0.5dB within 100KHz, ±1dB above 1MHz*frequency meter: 10Hz~30MHz*power supply : AC 220V(110V optional)
-
DT5 -
North Atlantic Industries
The DT5 module (the enhanced version) features 16 independent, isolated, programmable channels that can be used for input voltage measurements (±80 V), or as a bi-directional current switch (up to 500 mA per channel). When programmed as a switch with the switch closed, both the current through the switch and the voltage across the switch can be monitored. These modules include diode clamping on each channel. Clamping is useful for inductive loads, such as relays and short circuit protection. Additional features of the DT5 (Enhanced Version) are listed below.
-
FG-109 -
PINTEK Electronics
*FG-109 is a function generator with a high resolution of 10MHz DDS.*Various output waveforms: Sine, Square, Triangle, Pulse, Anti-Pulse.*Variable DC offset control : ±10V(no load).*Store / Recall. 20 settings*Counter up to 60MHz high frequency.*AM with internal and external carry.*Sweep mode with Linear and Log slope.*FM wide modulation range up to 10 times.*The signal Attenuate can be -20dB or -40 dB.*USB terminal for computer operation.*LCD Display
-
Alliance Support Partners, Inc.
he ASP-DCD-00 board is a high impedance input clock divider circuit. It is designed to provide minimum load to a clock source for frequency measurement. It accept single ended (Unbalanced) or differential (Balanced) signals with amplitudes as little as 100mV rms; it divides the input signal frequency from 2 to 256 times depending on shunt jumper selections on J3. The board requires 5VDC 500mA power source to operate. The output is capable of driving 5V TTL logic levels.
-
Del-Tron Precision, Inc.
Del-Tron offers a wide range of linear positioners. These micrometer positioning stages and crossed roller positioning stages are available with travels ranging from .25” to 2.0”. All of are linear positioners are available in X, XY and XYZ configurations and can carry loads ranging from 4 lbs on our miniature ball slide series all the way up to 160 lbs on our crossed roller positioning stages. All model numbers are available with inch or metric micrometers and mounting holes.
-
F-SIM-1553 -
Avionics Interface Technologies
Software GUI Application for Operating AIT MIL-STD-1553 Interfaces - Bus Monitor Captures & Recordings - Simulate Bus Controller and Remote Terminals (up to 31) - Operate Multiple Bus Channels (and MIL-STD-1553 Modules) Simultaneously - Replay Previously Captured Bus Data - Full Error Injection & Detection - Engineering Unit Displays & Software Widgets - MIL-STD-1553 A/B Mode Code operations - Also Supports ARINC 429, ARINC 664, Ethernet, & Data Load operations