Showing results: 2746 - 2760 of 3748 items found.
-
SeaGuard -
Aanderaa Data Instruments AS
The SEAGUARD® is the core module used in small and medium sized underwater observatories. Whether used as a multipurpose instrument, or as a hub for strings in the water column, the SeaGuard manages connected sensors and the real-time communication of data and meta-data to shore. In autonomous configurations, long battery life is achieved with aggressive power routines keeping the full system at the lowest power levels possible.
-
782630-01 -
NI
The PCIe-6536 can continuously stream data over the PCI Express bus. It's an ideal solution for interfacing and testing image sensors or display panels. The module is also well-suited for other common digital applications such as pattern I/O, change detection, protocol emulation, or other custom digital interfacing. It features selectable voltage levels and per-channel directional control of the digital lines.
-
782629-01 -
NI
The PCIe-6535 can continuously stream data over the PCI Express bus. It's an ideal solution for interfacing and testing image sensors or display panels. The module is also well-suited for other common digital applications such as pattern I/O, change detection, protocol emulation, or other custom digital interfacing. It features selectable voltage levels and per-channel directional control of the digital lines.
-
Megger Group Ltd.
Primary current injection testing is utilised in high current/high voltage scenarios found at large electrical installations such as substations. A large current (between 100A and 20,000A depending on system specifications and test requirements) is injected directly on the primary side of the electrical system such as a circuit breaker. The objective of the test is to identify how the system operates under various levels of current load.
-
Power Diagnostix Systems GmbH
Partial discharge testing – well established for high voltage equipment – becomes increasingly important for insulation systems of a lower voltage level. Changing to switching power supply and to IGBT control of induction motors, for instance, raise demands and testing needs for the insulation system. The modular concept of Power Diagnostix’ instruments allows offering customized solutions for automated and semi-automated testing.
-
TetraMAX® -
Synopsys, Inc.
The Synopsys TestMAX™ family of products offers innovative, next-level test and diagnosis capabilities for all digital, memory and analog portions of a semiconductor device. The Synopsys TestMAX family contains unique capabilities for automotive test and functional safety as well as technologies that unlock new levels of test bandwidth and efficiency by leveraging high-speed interfaces common on many designs.
-
Model T300U -
Teledyne Advanced Pollution Instrumentation
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.
-
HS4-50-DIFF -
TEAM SOLUTIONS, INC.
* record length is 131060 samples * 128K samples on screen without loss of information * free settable pre trigger position, from 0 to 100% * easy time axis zoom using unique scaleable sroll bar slider * free adjustable sample frequency * vertical offset and gain adjustable with graphical shiftable and scaleable axis * WYSIWYG trigger level, slope and hysteresis adjustment using combined trigger control * Auto setup to reduce setting time with unknown signals * linear/quadratical interpolation * extended cursor measurements * all settings accessable through popup menus * storing and recalling reference signals * software math channel available * easy to use speedbutton toolbar for easy access of all functions * comment tags to mark specific events in the signal * color hardcopy supported * explanatory comments with all controls * envelope mode * averaging of signals
-
PD5033 -
INSTOCK Wireless Components, Inc
PD5033 is an IP67 outdoor, weather resistant, DC blocking, three way, RF broadband, 50 ohm, power divider, power combiner furnished with N type coaxial connectors. The passive Wilkinson design passes RF and the 10 MHz reference signal through both ports while blocking DC current. This configuration is typically used in combining applications to prevent passing DC to the sum and adjacent ports. Max voltage rating at the DC blocked ports is 50 VDC. All wireless band applications in the frequency range from 698 to 2700 MHz are covered with best in class RF performance. The RoHS compliant PD5033 is a bidirectional device capable of 40 W max microwave input power levels in both power splitter and combiner apps. See 3 way power divider input rating tables for additional power handling info.
-
PD5023 -
INSTOCK Wireless Components, Inc
PD5023 is an IP67 outdoor, weather resistant, DC blocking, two way, RF broadband, 50 ohm, power divider, power combiner furnished with N type coaxial connectors. The passive Wilkinson design passes RF and the 10 MHz reference signal through both ports while blocking DC current. This configuration is typically used in combining applications to prevent passing DC to the sum and adjacent ports. Max voltage rating at the DC blocked ports is 50 VDC. All wireless band applications in the frequency range from 698 to 2700 MHz are covered with best in class RF performance. The RoHS compliant PD5023 is a bidirectional device capable of 40 W max microwave input power levels in both power splitter and combiner apps. See 2 way power divider input rating tables for additional power handling info.
-
PD5123 -
INSTOCK Wireless Components, Inc
PD5123 is an IP67 outdoor, weather resistant, DC blocking, two way, RF broadband, 50 ohm, power divider, power combiner furnished with SMA type coaxial connectors. The passive Wilkinson design passes RF and the 10 MHz reference signal through both ports while blocking DC current. This configuration is typically used in combining applications to prevent passing DC to the sum and adjacent ports. Max voltage rating at the DC blocked ports is 50 VDC. All wireless band applications in the frequency range from 698 to 2700 MHz are covered with best in class RF performance. The RoHS compliant PD5123 is a bidirectional device capable of 40 W max microwave input power levels in both power splitter and combiner apps. See 2 way power divider input rating tables for additional power handling info.
-
PD5043 -
INSTOCK Wireless Components, Inc
PD5043 is an IP67 outdoor, weather resistant, DC blocking, four way, RF broadband, 50 ohm, power divider, power combiner furnished with N type coaxial connectors. The passive Wilkinson design passes RF and the 10 MHz reference signal through both ports while blocking DC current. This configuration is typically used in combining applications to prevent passing DC to the sum and adjacent ports. Max voltage rating at the DC blocked ports is 50 VDC. All wireless band applications in the frequency range from 698 to 2700 MHz are covered with best in class RF performance. The RoHS compliant PD5043 is a bidirectional device capable of 40 W max microwave input power levels in both power splitter and combiner apps. See 4 way power divider input rating tables for additional power handling info.
-
PD5143 -
INSTOCK Wireless Components, Inc
PD5143 is an IP67 outdoor, weather resistant, DC blocking, four way, RF broadband, 50 ohm, power divider, power combiner furnished with SMA type coaxial connectors. The passive Wilkinson design passes RF and the 10 MHz reference signal through both ports while blocking DC current. This configuration is typically used in combining applications to prevent passing DC to the sum and adjacent ports. Max voltage rating at the DC blocked ports is 50 VDC. All wireless band applications in the frequency range from 698 to 2700 MHz are covered with best in class RF performance. The RoHS compliant PD5043 is a bidirectional device capable of 40 W max microwave input power levels in both power splitter and combiner apps. See 4 way power divider input rating tables for additional power handling info.
-
Fido® X4 -
Teledyne FLIR
The Fido X4 is a premium handheld explosives trace detector (ETD) that delivers unmatched sensitivity for a broad range of explosives, so you can easily detect threats at levels others can’t. Next generation FLIR TrueTrace® detection technology features a new five-channel sensor array that delivers expanded threat coverage, enhanced sensitivity, and identification in a wide range of environmental conditions. The simplified user interface features onboard video tutorials, user prompts, and color- coded alarms with strength indicators so you can operate quickly and decisively. Analysis and reporting of results are made simple through multiple modern connectivity options, allowing critical data to be shared quickly. From high-volume checkpoint and randomized screenings to foot patrol and standoff operations, Fido X4 is ready to go when and where you need it.
-
Synchronous Accumulation (Order Analysis) -
ZETLAB Company
Order analysis is one of the most convenient and efficient methods for diagnostics and balancing of rotating mechanisms and transmission gears. With an RPM sensor and a vibration sensor, it is possible to study the time characteristics of gear vibration signals. It is a well-known fact that a signal from a vibration sensor is affected by signals from other sources. To tune out from the disturbing signals, the synchronous signal accumulation method is used. For each shaft rotation, the RPM sensor provides a rotation mark. This signal serves as a triggering strobe for the vibration sensor signal sweeping. The obtained signal sweeps are combined. All the sources of the signals related to the shaft frequency (frequency of rotation) are accumulated and increased in the accumulator linearly proportionally to the N number of rotations. All other signals that are not correlated with the shaft frequency are accumulated proportionally to N1/2 and in case of a greater number of averagings, the useful signal exceeds the interference level.