Filter Results By:

Products

Applications

Manufacturers

Showing results: 286 - 300 of 310 items found.

  • Chassis - Controls up to 16 8x1 Modules, 32 4x1 Modules or Mixtures or 8x1's, 4x1's, 2x1's and 2x2 Modules in Any Combination or Configuration up for up to 128 Relay Drives

    CXM/128-MF - Cytec Corp.

    These Chassis controls up to 16 8x1 modules, 32 4x1 modules or mixtures of 8x1"s, 4x1"s, 2x1"s and 2x2 modules in any combination or configuration for up to 128 relay drives. LEDs on the front panel show switch and power status. Add Switch Modules, display / driver modules and a Control Module to complete the system or simply buy the chassis wired out to D connectors to control your own relays. A manual control is optional. Chassis is available with sink or source relay drivers from + 5 to + 28 volts, ot TTL drivers for programmable attenuators. Firmware commands for Fade and Handover for WiFi, Cell Phone and WiMax labs. Fully custom systems built with little to no NRE.

  • Scienlab Battery Test System – Pack Level, 330 KW

    SL1740A - Keysight Technologies

    Keysight’s SL1700A Scienlab Battery Test System – Pack Level Series allows to realistically emulate the environment of the future battery pack application in order to test the high-power battery pack comprehensively and improve its functions and safety. The growing demand of e-mobility increases the need of vast battery test labs for EV battery development. Keysight developed the SL1700A Series to accelerate the development and validation of batteries. It offers a voltage range of up to 1500 V and power options between 100 and 300 kW including a Performance Bundle to increase the power up to 330 kW. The new high-voltage SiC (silicon carbide) technology provides a high energy efficiency on a small footprint and helps to minimize your operating costs.

  • Scienlab Battery Test System – Pack Level, 110 KW Compact Version

    SL1710A - Keysight Technologies

    Keysight’s SL1700A Scienlab Battery Test System – Pack Level Series allows to realistically emulate the environment of the future battery pack application in order to test the high-power battery pack comprehensively and improve its functions and safety. The growing demand of e-mobility increases the need of vast battery test labs for EV battery development. Keysight developed the SL1700A Series to accelerate the development and validation of batteries. It offers a voltage range of up to 1500 V and power options between 100 and 300 kW including a Performance Bundle to increase the power up to 330 kW. The new high-voltage SiC (silicon carbide) technology provides a high energy efficiency on a small footprint and helps to minimize your operating costs.

  • Scienlab Battery Test System – Pack Level, 220 KW

    SL1730A - Keysight Technologies

    Keysight’s SL1700A Scienlab Battery Test System – Pack Level Series allows to realistically emulate the environment of the future battery pack application in order to test the high-power battery pack comprehensively and improve its functions and safety. The growing demand of e-mobility increases the need of vast battery test labs for EV battery development. Keysight developed the SL1700A Series to accelerate the development and validation of batteries. It offers a voltage range of up to 1500 V and power options between 100 and 300 kW including a Performance Bundle to increase the power up to 330 kW. The new high-voltage SiC (silicon carbide) technology provides a high energy efficiency on a small footprint and helps to minimize your operating costs.

  • Near Field Scanning Optical Microscope

    MCL-NSOM - Mad City Labs Inc.

    The MCL-NSOM is a fully operational near field scanning optical microscope. It has been built on Mad City Labs versatile RM21™ inverted optical microscope which allows users to convert between NSOM, SPM, and fluorescence optical microscopy techniques. The MCL-NSOM builds on our successful resonant probe SPM and incorporates common elements such as the MadPLL® phase lock loop controller. The NSOM also exploits our expertise in precision motion control by including six axes of motorized positioning, for the sample and NSOM probe, and three axes of closed loop nanopositioning to provide exceptional position resolution and accuracy. The MCL-NSOM also includes a 635nm laser excitation source, fiber launch, oil immersion objective lens (100x, 1.25 N.A.), CMOS alignment camera and avalanche photodiode detector. The microscope configurable design allows researchers to tailor the instrument for many different optical microscopy techniques including near field spectroscopy. The MCL-NSOM is operated in aperture mode with shear force feedback. The standard 5 modes are supported: illumination, collection, illumination and collection, reflection and reflection collection. We supply a LabVIEW™ based software package which automates the motion control features.

  • FCC Testing and Certification

    Washington Laboratories LTD.

    Washington Labs provides FCC Testing and has many years of experience and expertise in the following:FCC Part 15 Testing for Computing Devices, Cordless Telephones, Satellite Receivers, TV Interface Devices, Receivers, Low Power Transmitters, and Spread Spectrum Transmitters, UNII & others.FCC Part 22 Testing for Cellular TelephonesFCC Part 25 Testing for Satellite CommunicationsFCC Part 90 Testing for Private Land Mobile Radio Services – Includes Paging Devices and Mobile Radio TransmittersFCC Part 95 Testing for Personal Radio ServicesFCC Part 18 Testing for Industrial, Scientific, and Medical Equipment i.e. Microwave, and RF Lighting Ballast (ISM)FCC Part 24 Testing for Personal Communications SystemsFCC Part 80 Testing for Marine Radio Transmitters

  • Individual UPC Bar Code Standards

    Applied Image, Inc.

    The UPC Verification Calibration standards are a unique set of symbols that assures an exact and reliable primary bar code standard exists for UPC codes based on ANSI X3.182/ISO 15416 methodology. These standards assures that manufactures of verification equipment, scanners, QC labs and end users now have an accurate basis for checking the measurement capabilities of their equipment. These standards are intended as a fundamental calibration tool for an QC program, providing a continuous scale from best to worse case characteristics of each parameter. With complete NIST traceable data supplied, it is ideally suited to those requiring traceability, such as ISO certification. Each symbol is individually calibrated to ANSI X3.182/ISO 15416 standards using a custom built microdensitometer. These cards are supplied calibrated for use with a 6 mil scan aperture and 660nm wavelength. (calibration wit other aperture sizes or wavelengths is available)

  • Life Cyclic Durability Testing

    Environment Associates Inc.

    Environment Associates can provide everything you need for cyclic durability testing and performance fixturing. Services include mechanical cycling to a position or load, fatigue cycling to a fixed load, rotational torque cycling, and simple push/pull cycling. EA can design your fixture with electro-dynamic, air, or hydraulic assistance to mechanically move your part. All of our fixtures can be manufactured to withstand a wide range of temperature, humidity and vibration inputs. If required, forces can be monitored electronically, using a wide variety of inputs (i.e. strain gages, load cells, rotational transducers, thermocouples, shunts, and more). EA can create holding and check fixtures to perform “pre” and “post” evaluation for dimensional issues that may occur during testing. EA can provide fixtures for single tests run internally for EA test labs and can manufacture fixtures to be purchased directly by the customer for their internal use.

  • Standard Class AAA Solar Simulator

    TriSOL TSS - OAI

    Essential for testing virtually any material or product that is exposed to sunlight for long or short periods of time, OAI’s low-cost, Standard Solar Simulators deliver highly collimated, uniform light. Depending on configuration, output on these Solar Simulators is rated at 350W -5,000W.These Class AAA Solar Simulators feature OAI’s Advanced Uniform Beam Optics and are available with a choice of air mass filters to reproduce a wide range of solar spectra. For added flexibility, OAI’s proven lens and collimating mirror technology allows for a variety of exposure area sizes. A Class AAA Solar Simulator is an essential tool for manufacturing as well as R&D; it is indispensable in test labs, industry, and in universities. OAI Standard Solar Simulators are used in photobiology, biomedical, solar cell testing, cosmetic testing, and paints & coatings analysis. Based on 35+ years of proven UV light technology, OAI Solar Simulator Systems deliver repeatable, reliable, constant output, and measurement uniformity.

  • Si1145 UV / Ambient Light / Proximity Sensor

    SEN-36002 - Playing With Fusion Inc

    SEN-36002 is a highly integrated carrier board designed for the Si1145 UV, Ambient Light and Proximity sensor IC from Silicon Labs. This sensor has 100mLUX resolution, and has a dynamic range of 1 LUX to 128 kLUX with IR correction. This means that whether your application is indoors in poor lighting conditions or outside in full sunlight, this sensor has you covered. In addition, we added a high power LED (150mA max, 20 degree) to take full advantage of the proximity sensing capability of this IC - something you won't see on most competitive carrier boards. Integration is easy with 4 x 4-40 sized mounting holes at the corners of the PCB and signal translation to handle interface voltages from 3V to 5V. The board is interfaced via an I2C interface and function pins have been broken out to a 0.1" pin header. The INT pin is also broken out for interrupt capability.

  • Sophisticated Audio and Video Test Patterns

    VQL - VideoQ Inc

    VQL Instantly reveals your video display, codec, scaler, converter or other video device performance VQL test patterns cover all 3 levels of video QA/QC: Instant visual-aural Quality Estimation Objective Measurements of video and audio performance Fully automated (unattended) Quality Control VQL features: Compatibility with all commonly used software or hardware codecs and media players VideoQ VQV / VQMA / VQTS / VQDM compatible tests Wide range of video frame sizes: from 192x108 to 4096x3072 Variety of bit rates up to uncompressed 4:4:4 4K @60 fps, 48 bit per pixel Variety of video and audio formats, color spaces and level schemes All test patterns remain suitable for accurate measurements even after low bitrate coding, heavy scaling and/or cropping, e.g. after down-conversion for mobile devices Standard, custom and semi-custom tests for development labs, content processing facilities, CDN systems, software developers and high volume manufacturers

  • Software for Recordkeeping Reporting

    RegPerfect - Teledyne Monitor Labs

    Data management is vital to your company's bottom line and mission critical environmental compliance goals. Today's environmental professionals must learn to do more with less when faced with budget constraints, rising operating costs, and staff reductions. TML helps environmental professionals around the world meet these challenges by offering RegPerfect Software.The Teledyne Monitor Labs RegPerfect® software system is a state of the art Data Acquisition Handling and Reporting Sytem. RegPerfect® is the culmination of more than 40 years of experience in the data acquisition system business. The software is designed to comply with the data collection, quality assurance, and reporting requirements of federal and local regulatory agencies. Operating in real time, this rugged platform provides the visibility, connectivity and securityfor all of your environmental and operational needs related to the performance of your Continuous Emission Monitoring (CEM) System. For the most recent updates to the software, please visit the Product Status​ page.

  • Hazardous Location Syringe Pump

    100HLf - Teledyne LABS

    Teledyne LABS HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compat​ible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.

  • Hazardous Location Syringe Pump

    500HLf - Teledyne LABS

    The Teledyne LABS HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compatible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.

  • Hazardous Location Syringe Pump

    260HLf - Teledyne LABS

    Teledyne LABS HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compatible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.

Get Help