Filter Results By:

Products

Applications

Manufacturers

LAN

The communication system of electronic devices within a building.

See Also: Instrument Control Buses, PXI, PXIe, LXI, AXIe, PCIe, GPIB, USB, PCI, Ethernet, LIN, Mesh, WLAN


Showing results: 556 - 570 of 602 items found.

  • OTDR

    palmOTDR - ShinewayTech

    The compact palmOTDR now offers even more testing capacities, flexibility and value with combination of 850/1300/1310/1490/1550/1625/1650nm (Mono/double/triple wavelength) OTDR, 1310/1490/1550nm PON Power Meter, Stabilized Laser Source and VFL. The OTDR wavelengths cover the applications of regular end-to-end fiber characterization (1310/1550nm), premise/enterprise LAN testing (850/1300nm), FTTx fiber link construction verification (1490nm) and PON live fiber troubleshooting (1625/1650nm with filter). The integrated PON Power Meter can perform in-service testing of all PON signals (1310/1490/1550nm) on any spot of the network featuring pass-through design and burst mode support. palmOTDR is your ultimate solution to meet various testing requirements of entire fiber network.

  • Wi-Fi Testing

    National Technical Systems

    NTS has been testing wireless home networking devices (typically referenced as “Wi-Fi” devices) almost since their introduction. Since 1999, NTS has been perform testing of wireless LAN products based on the IEEE-802.11 standard (e.g., 802.11a, 802.11b, 802.11g, 802.11n, and even the latest drafts of 802.11ac and 802.11ad). Wi-Fi products are typically designed to allow you to connect your personal computer to a wireless network typically connected to the Internet. Wi-Fi “hot-spots” are available in locations across the country (e.g., coffee shops, hotels, etc.), and have become common-place. However, Wi-Fi is expanding into other areas, including healthcare and smart energy (e.g., connecting your smart device to the internet to track energy usage, etc.).

  • 6U CompactPCI® Rear Transition Board for MIC-3395

    RIO-3315 - Advantech Co. Ltd.

    The RIO-3315 is the first Rear Transition Module (RTM) supporting PCIe connectivity to the main CPCI board enabling significant value-added features and extensions to next generation CPCI blades such as MIC-3395. The RIO-3315 supports: one PS/2 port, six USB ports, two RS-232 ports, two SATA ports, two Gigabit Ethernet ports, one digital and one integrated (digital/analog) DVI port. Three versions of RIO-3315 provide a choice of storage and LAN options. The RIO-3315-A1E with LSI1064E SAS controller supports a 4-port SAS controller with RAID, which allows switching between four internal SAS/SATA or four external MiniSAS ports. The RIO-3315-B1E supports SATA disk drives and SATA RAID via the QM67 PCH.

  • Electronic DC Load, 80V, 80A, 400W With/without Remote Interfaces

    LD400 Series - Aim-TTi

    Versatile solution for testing dc power sourcesConstant current, resistance, conductance, voltage and power modesWide voltage and current range, 0 to 80V and 0 to 80A400 watts continuous dissipation at 28°C (360W at 40°C)600 watts short-term dissipation (up to 60 seconds)Low minimum operating voltage of <1V at 40AHigh resolution and accuracy for level settingBuilt-in transient generator with variable slewCurrent monitor output for waveform viewingVariable drop-out voltage for battery testingHigh resolution backlit graphic LCD with soft key controlAnalogue remote control of levels and TTL control of on/off and transient switchingFront and rear input terminals (front terminals 30A max.)Full bus control via USB, RS232 and LXI compliant LAN interfaces (LD400P)GPIB option (LD400P only)

  • Programmable DC Electronic Loads

    SDL1000X/X-E Series - SIGLENT Technologies

    SDL1000X/SDL1000X-E series Programmable DC Electronic Load has a 3.5 inch TFT-LCD display, a user-friendly interface and superb performance specifications. The SDL1020X/SDL1020X-E models feature an input range of 150 V/30 A 200 W while the SDL1030X/SDL1030X-E have an input range of 150 V/30 A 300 W. The SDL1000X series leads with measurement resolution of 0.1 mV/0.1 mA and the base SDL1000X-E series resolution is 1 mV/1 mA and adjustable current rise times from 0.001 A/μs~2.5 A/μs. For remote communication and control, the SDL series includes RS232/USB/LAN interface types. The SDL1000X series delivers stability over a wide range of applications and can meet all kinds of testing requirements. including: Power, battery/handheld device design, industry, LED lighting, automotive electronics, and aerospace.

  • Clock Synchronization

    Analog Devices Inc.

    Analog Devices Clock synchronizers are designed for wired networking applications, providing the clock redundancy functionality needed to maximize system uptime. Our technology supports clock synchronization with common standards, including 1 pulse per second (PPS) output signal from a GPS receiver. GPS signals are broadly available and utilize an extremely stable atomic clock as its time base, but they are often noisy. Systems rely on the IEEE1588 timing protocol to establish synchronous communications across the wired network, including synchronous Ethernet and synchronous digital hierarchy (SDH) to optical transport network (OTN) mapping/demapping. The IEEE1588 protocol has emerged as the preferred method for Clock synchronizing systems throughout both computer networks and local area networks (LAN).

  • Multi-channel DC Electronic Load

    IT8700 Series - I-TECH Electronic Co., Ltd

    IT8700 series programmable DC electronic load adopts removable modules design, supports up to 16 channels with mainframe extension transient mode up to 25 kHz, which improves your test efficiency, with high resolution and accuracy. Users can freely choose in the 8 load modules according to the number of channels and power requirements, controlled by mainframe control panel, or controlled by host computer software via built-in LAN / RS232 /USB / GPIB interface. IT8700 is with adjustable slope, list function, automatic test and other functions, and can be applied to multiple or single output AC/ DC, DC / DC power converters, chargers and other power supply electronic components performance test, also can be used in ATE test system, solar cells, LED, communications testing, aerospace and other fields.

  • Sound Pressure Level Logging Software

    RT-Capture 3 - WavCapture

    RT-Capture 3 is a SPL (Sound Pressure Level) logging software supporting a number of national and international standards. It is intended for self-governance of sound levels during music events, concerts and festivals.RT-Capture 3 has octave and third octave logging implemented for environmental noise control.RT-Capture has integrated networking for web-server over LAN and remote control and display of up to 250 units.RT-Capture uses a standard PC-soundcard and supports measurements from two microphones.RT-capture records a log-file with SPL-data (such as Leq, LAmax, LCpeak) and make compressed sound recordings of the audio signal.The log-file can be watched graphically and audio can be played back from a cursor point in the graph. The SPL-measurement is validated to the IEC 61672 standard and other international standards.Protocol according to several national standards can be printed. A scheduler can be set to email the log-file during logging.

  • Digital Power Meter, 30A

    66205 - Chroma Systems Solutions, Inc.

    Voltage Ranges:15/30/60/150/300/600 Vrms1200Vrms (optional)Current Ranges : 0.005/0.02/0.05/0.2/0.3/0.5/2/5/20/30 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bitsAnalog/Digital converters withmax samipling rate up to 250kHzCapable of meeting the IEC 61000-4-7harmonics measurement requirementsSmart Range function provides seamlesspower integration measurement underauto range modeSupports external shunt and CT forhigher current applications5 mA minimum current range &0.1mW power resolutionMeets ENERGY STAR /EN 50564/IEC 62301/ErP requirementsUser-define criteria providesautomatic PASS/FAIL indicationsTHD and user-specify order distortionmeasurementInrush current and energy measurementsVoltage/ Current harmonics measurementsup to 100 ordersUSB (Host) interface provides data loggingfunctionalitySupport GPIB, USB, RS232, LAN (option)interface

  • GPIB-ENET/1000, Ethernet GPIB Instrument Control Device - North America 240VAC

    781630-05 - NI

    The GPIB‑ENET/1000 is an IEEE 488 controller device for computers with an Ethernet port. You can use this device to share a single GPIB system among many networked users or to control several test systems from a single networked host. The GPIB‑ENET/1000 features a password-protected web interface for easy configuration. It can also control IEEE 488 devices from anywhere on an Ethernet‑based (LAN) TCP/IP network (Gigabit, 100BASE‑TX, 10BASE‑T). Each device interfaces to and shares up to 14 GPIB devices from several network hosts, and you can control up to 100 GPIB‑ENET/1000 interfaces with a single computer. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

  • GPIB-ENET/1000, Ethernet GPIB Instrument Control Device

    781630-07 - NI

    Ethernet GPIB Instrument Control Device - The GPIB‑ENET/1000 is an IEEE 488 controller device for computers with an Ethernet port. You can use this device to share a single GPIB system among many networked users or to control several test systems from a single networked host. The GPIB‑ENET/1000 features a password-protected web interface for easy configuration. It can also control IEEE 488 devices from anywhere on an Ethernet‑based (LAN) TCP/IP network (Gigabit, 100BASE‑TX, 10BASE‑T). Each device interfaces to and shares up to 14 GPIB devices from several network hosts, and you can control up to 100 GPIB‑ENET/1000 interfaces with a single computer. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

  • GPIB-ENET/1000, Ethernet GPIB Instrument Control Device - Brazil 127/220VAC

    781630-12 - NI

    The GPIB‑ENET/1000 is an IEEE 488 controller device for computers with an Ethernet port. You can use this device to share a single GPIB system among many networked users or to control several test systems from a single networked host. The GPIB‑ENET/1000 features a password-protected web interface for easy configuration. It can also control IEEE 488 devices from anywhere on an Ethernet‑based (LAN) TCP/IP network (Gigabit, 100BASE‑TX, 10BASE‑T). Each device interfaces to and shares up to 14 GPIB devices from several network hosts, and you can control up to 100 GPIB‑ENET/1000 interfaces with a single computer. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

  • GPIB-ENET/1000, Ethernet GPIB Instrument Control Device - China 220VAC

    781630-10 - NI

    The GPIB‑ENET/1000 is an IEEE 488 controller device for computers with an Ethernet port. You can use this device to share a single GPIB system among many networked users or to control several test systems from a single networked host. The GPIB‑ENET/1000 features a password-protected web interface for easy configuration. It can also control IEEE 488 devices from anywhere on an Ethernet‑based (LAN) TCP/IP network (Gigabit, 100BASE‑TX, 10BASE‑T). Each device interfaces to and shares up to 14 GPIB devices from several network hosts, and you can control up to 100 GPIB‑ENET/1000 interfaces with a single computer. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

  • GPIB-ENET/1000, Ethernet GPIB Instrument Control Device - Korea 220VAC

    781630-09 - NI

    The GPIB‑ENET/1000 is an IEEE 488 controller device for computers with an Ethernet port. You can use this device to share a single GPIB system among many networked users or to control several test systems from a single networked host. The GPIB‑ENET/1000 features a password-protected web interface for easy configuration. It can also control IEEE 488 devices from anywhere on an Ethernet‑based (LAN) TCP/IP network (Gigabit, 100BASE‑TX, 10BASE‑T). Each device interfaces to and shares up to 14 GPIB devices from several network hosts, and you can control up to 100 GPIB‑ENET/1000 interfaces with a single computer. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

  • GPIB-ENET/1000, Ethernet GPIB Instrument Control Device - Swiss 220VAC

    781630-02 - NI

    The GPIB‑ENET/1000 is an IEEE 488 controller device for computers with an Ethernet port. You can use this device to share a single GPIB system among many networked users or to control several test systems from a single networked host. The GPIB‑ENET/1000 features a password-protected web interface for easy configuration. It can also control IEEE 488 devices from anywhere on an Ethernet‑based (LAN) TCP/IP network (Gigabit, 100BASE‑TX, 10BASE‑T). Each device interfaces to and shares up to 14 GPIB devices from several network hosts, and you can control up to 100 GPIB‑ENET/1000 interfaces with a single computer. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

Get Help