Filter Results By:

Products

Applications

Manufacturers

Inverters

Devices which change DC input into AC output or clean an AC Sinewave signal from AC source.


Showing results: 151 - 165 of 201 items found.

  • Analog Output Data Acquisition (DAQ) Products

    Acces I/O Products, Inc.

    Analog Output boards are useful when you need an output where the condition is not just an on or off state. Analog Output boards convert digital values generated by software into the analog voltage or current signals required for controlling frequency inverters, valves, sliders, brightness of lights, or things controlled by motors and other mechnical transducers.

  • Resistive & Capacitive AC Load Bank

    RCD - Junxy Energy

    RCD AC load banks are used to test the REAL working condition of UPS, rectifier, inverter and etc who are loaded by non-linear or electronic load with non-constant resistance such as computer, networking equipments and etc. Through the accurate detection of its output and power quality, users could avoid the inadequate loading capacity or cause pollution to power grid, so as to guarantee supply security. JUNXY RCD load banks leading power factor loads are created to debug power supply system parameters such as its crest factor test.

  • ePortable Load Bank

    Swift - Simplex Inc

    Quick and easy testing of small generators is possible with the Simplex Swift-e Portable Load Bank. Fully self-contained, lightweight and hand transportable, the Swift-e can be used to test and maintain engine generators, inverters, batteries, battery chargers, rectifiers and small UPS systems. Swift-e's are available as AC or DC units with capacities up to 15,000 watts of load switchable in 250W increments.

  • Electric Attitude Gyroscopes

    5000EG-series - Sigma Tek, Inc.

    The 5000EG gyro is based on our air-driven 5000B model, whose proven reliability has made it the industry standard for many years. There are two models available: 14 and 28 VDC. The rotor is precisely machined from a heavy-metal tungsten alloy, which has a higher mass than brass, contributing to the instrument’s demonstrated stability. The electric motor is driven by a built-in power inverter, and has an integrated air-erection mechanism. A warning flag is deployed upon loss of primary power. During acrobatic flights or short stops, the gyro’s mechanism can be caged whenever the knob is pulled.

  • AC Load Bank

    AC-LB-Series - Eagle Eye Power Solutions

    Eagle Eye AC Load Banks are commonly used for testing generator sets, UPS units, aircraft power inverters and other government and military AC power sources. The Eagle Eye AC LB-Series is the smallest in the industry and offers unmatched durability in even the harshest testing environments. Eagle Eye offers several standard models as well as custom AC Load Banks.

  • Resistive AC Load Bank

    Junxy Energy

    AC load bank testing offers you whole solutions of predictive failure analysis for UPS(uninterrupted power supply), generator, transformers, PV system, inverter etc, to validate the condition and output of such power systems comprehensively. Integrated AC & DC load bank could be made in one unit or separately with different load voltages as per your need for different applications.

  • DC In AC Clamp Tester

    M-800P - MULTI MEASURING INSTRUMENTS Co., Ltd.

    *Model 800P is the world’s first clamp meter which can detect smallDC current in AC circuit in addition to general AC/DC current measurement.*By using this clamp meter, DC offset surveillance can be madeeasily in the actual fields like as solar inverters, etc. and it is possibleto check if the DC component in AC circuit is less than 1% ofthe rated AC current or not, according to the regulation.

  • HEV / EV / Grid Emulators and Test Systems

    Keysight Technologies

    With Scienlab test systems and test software, Keysight offers customized test environments for the development and testing of electronic components according to hybrid and electric vehicle testing standards. Our solutions help you to accelerate your e-mobility applications from the battery, Battery Management System (BMS), inverter, the charging interfaces of Electric Vehicle (EV), and Electric Vehicle Supply Equipment (EVSE).

  • NI Electric Motor Simulation Toolkit

    NI

    PMSM, ACIM, SRM, and power inverter models for high-performance simulationHigh-fidelity simulations with support for user-defined parameter lookup tables or JMAG-RT models. Open software for full flexibility and customizationLabVIEW project templates to build a software-only simulation and hardware-in-the-loop application. Direct integration with NI VeriStand for configuration-based real-time test. Models for desktop simulation, LabVIEW Real-Time simulation, and FPGA-based simulation

  • AC Standard Load Banks

    Ohm Loads Powertek Inc.

    The AC SERIES load banks are designed for connection to any 120VAC or 240VAC single-phase, 120VAC/240VAC split voltage, or 120/208VAC three-phase WYE source. The AC SERIES is ideal for integration into racked test systems or benchtop testing of aircraft power inverters, small generator sets, UPS units and any other AC power source. These standard models are easily configured for other voltage and power ratings.

  • Inverter/Chargers

    Xantrex Technology

    A Xantrex inverter/charger is a combination of an inverter, battery charger and transfer switch into one complete system. When AC power is available, the inverter/charger recharges the house batteries. It also allows any surplus AC power to pass through and power downstream AC loads, such as a television set or microwave oven. When AC power is disconnected, the unit inverts DC battery power into AC electricity.

  • Bidirectional DC Power Supply

    62000D - Chroma ATE Inc.

    Chroma 62000D programmable bidirectional DC power supplies provide both power source and load characteristics. These two quadrant power supplies allow power from the DUT to be converted back to the utility grid and so are ideal for testing renewable energy power systems such as PV, storage, and EV inverters as well as a wide range of bidirectional power conditioning system (PCS) and may also be used as a battery simulator.

  • E-Mobility

    IRS Systementwicklung GmbH

    The main components of electrical and hybrid vehicles are the electrical motor and the battery. Furthermore, inverters convert the DC voltage of the battery into AC currents for the motor. Battery chargers convert the AC voltage from the grid to the DC voltage of the battery, DCDC-converters shift energy between LV and HV battery and power distribution units make sure, that all components including additional loads may be safely connected in the car.

  • Grid Simulator

    PAS-F - Intepro Systems

    The Intepro PAS-F Series is a broad line of programmable three phase output regenerative utility grid simulator products. With power levels ranging from 45kVA up to 1.6MVA, the series is capable of testing the largest of dispersed energy inverters. The PAS-F combines utility grid simulation with regenerative bi-directional AC source controlled power that is capable to both source and sink full current from the equipment under test (EUT).

  • AC Power Sources

    AMETEK Programmable Power, Inc.

    AMETEK Programmable Power's AC power sources range from 800VA to 480kVA. From compliance test systems to rack-mounted industrial power subsystems, AMETEK Programmable Power is the leader in the design and manufacture of precision, programmable AC power sources used in R&D, test and measurement, avionics testing, inverter testing, arbitrary waveform generation, bulk power and power conditioning applications across a wide variety of industrial segments.