  • TRMS AC/DC Clamp-on Power

    HT9023 - HT Italia Srl

    HT9023 has been designed to measure AC, DC AC+DC current up to 1000A in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/EN61010-1. The clamp also measures DC voltage up to 1500V, AC, AC+DC voltage up to 1000V, Active, Reactive and Apparent Power, Power Factor, Energy, voltage/current harmonic analysis up to the 25th with THD% calculation in balanced single-phase or three-phase systems.

  • Test Card Generator

    TCG1 - NG Systems Ltd

    This generator provides a standard 75O, 1-volt p-p; PAL encoded CCIR video signal for the testing of monitors and other CCTV equipment. The Test Card Generator TGC1 may display one of four test patterns , (i) Colour bars with reference, (ii) Red Raster, (iii) Peak White Raster and (iv) Composite Test Card (see picture below). The Test Card Pattern incorporates many of the attributes of broadcast test patterns for the evaluation and setting up of CCTV video equipment.

  • Mobilize

    Protec Instrument Corp

    A complete wireless solution that connects your Pronk test equipment to your smart device!* Take complete control of your Pronk products — Safe-T Sim® Mobilize Electrical Safety Analyzer,  Mobilize SC-5 SimCube® NIBP Simulator, Mobilize OX-2 OxSim Flex® SpO2 Simulator, and Mobilize FlowTrax® IV Pump Analyzer — to set up your own test protocols or run your CMMS procedures right from your Apple iOS device.

  • Time Domain Reflectometer

    TDR 500 - BAUR Prüf- und Messtechnik GmbH

    Handheld Time Domain Reflectometer. The handheld time domain reflectometer TDR 500 and TDR 510 are used for fault location in all metal cables such as power cables, coaxial cables, data cables and communication cables.* Configurable for various measurement ranges and cable types* Standard-compliant, safe measurements on life cables through the measurement category CAT IV / 600 V (with separation filter)* Ideal for fault location in the area of telecommunication, video technology, data and security technology

  • 2000A True RMS AC/DC Clamp Meter

    Extech 380926 - Extech Instruments Corporation

    The 380926 is a category IV, 2000-Amp, TRMS AC/DC Clamp Meter which has a rugged 2 in. jaw that accommodates two 500MCM cables. A built-in full-function DMM can measure AC/DC Voltage and Current, Resistance, capacitance, frequency, Duty Cycle, Diode and Continuity. Measurements are displayed on the large 4000 count backlit display for easy viewing in dimly lit areas. Additional features include DCA push button zero, Data Hold, and Relative function. Complete with test leads and 9V battery.

  • Comprehensive Suite of Software Tools for Semiconductor Test Applications

    ICEasy Test Suite - Marvin Test Solutions, Inc.

    Marvin Test Solutions' ICEasy Test Suite is supplied with both the TS-900 and TS-960 semiconductor test platforms and provides a comprehensive set of software tools - facilitating the development and debugging of test programs for semiconductor devices. In addition the suite includes I-V curve and Shmoo plot tools for analyzing a device's DC and AC characteristics. The complete suite of tools interfaces seemlessly with Marvin Test Solutions' ATEasy®, a test executive and test development evironment which is supplied with each TS-900 / TS-960 system.

  • Rechargeable Multifunction Tester

    ET4000 - Martindale Electric Co. Ltd

    The new ET4000 tester carries out all the tests needed to verify the safety of electrical installations in domestic, commercial and industrial wiring installations in accordance with the latest regulations.

    Everything about the new ET Series has been designed to save time and make testing easier.

    Fast, reliable high current and non-trip loop testing comes as standard together with a high level of input protection and a CAT IV safety rating .

    Supplied with a full range of accessories.

  • Non-Contact Voltage Tester

    NCVT-1 - Klein Tools, Inc.

    Non-contact detection of voltage in cables, cords, circuit breakers, lighting fixtures, switches, outlets, and wires.High intensity, bright green LED indicates the tester is operational and aids in illuminating the workspace.When voltage is detected, a high intensity, bright red LED illuminates and a warning tone sounds.Discrete digitally controlled ON/OFF power button.Auto power-off feature conserves and extends battery life.Microprocessor controlled low-battery indicator and tester shutdown.CAT IV 1000 Volt safety rating provides expanded operation and protection.

  • Module Testing Station

    QuickSun® 550CE - Endeas Oy

    QuickSun 550CE is certified by TÜV Rheinland and a detailed test report is included with every simulator proving Class A+A+A+ performance with respect to spectrum, irradiance non-uniformity and short term instability (STI). Long term instability (LTI) is also within Class A+ tolerances during the 40 ms long flash pulse. IV characteristics are recorded with an electronic load and proprietary electronics unit which measures voltage, current and irradiance signals when module is swept e.g. from short circuit to open circuit or vice versa.

  • Standalone Terrestrial Solar Array Photovoltaic Simulator

    TerraSAS (ETS Series) - AMETEK Programmable Power, Inc.

    For microgrids, energy storage, and inverter test applications, the TerraSAS™ series photovoltaic (PV) simulators are specifically designed to emulate the dynamic electrical behavior of a terrestrial PV solar array. They offer low output capacitance and high closed loop bandwidth to keep up with the advanced Maximum Power Point Tracking (MPPT) algorithms used in today’s grid-tied inverters. The Embedded TerraSAS (ETS) is a high performance solution in a small form factor that combines an agile power supply with an innovative I-V curve generator in a single standalone unit.

  • Non-Contact Phase Sequence Tester - Tests up to 1000VAC with Visual/Audible Indication

    Extech PRT200 - Extech Instruments Corporation

    The PRT200 is a non-contact phase sequence tester that tests up to 1000 VAC with visual/audible indication. The tester has a 45 to 65Hz frequency range, features adjustable Hi/Lo LED brightness switch for making measurements in dimly lit areas or sunlight, low battery warning and fully insulated alligator clips with wide jaws. The product has a CAT IV 600 Volt safety rating and is complete with a year warranty, three built-in 30 in. test leads with large color-coded alligator clips, 4 AA batteries, and a pouch case.

  • Pulsed IV-Curve Solutions

    ESDEMC Technology LLC

    Pulsed IV-Curve Test and Analysis System is our new development for 2015. It is an advanced and compact pulsed IV-curve characterization system designed to simulate pulsed ESD events such as TLP, vf-TLP, HMM, HBM, EFT, and LV-Surge. It will monitor the transient voltage and current waveform during the pulse in ps or ns segment, and test the pre- and post-pulse status (leakage current, breakdown voltage, biasing current, static IV curve, etc) of the device under test (DUT), such as protection devices, semiconductors, circuit modules, touch panel sensor, etc.

  • 11 Function Heavy Duty True RMS Industrial MultiMeter

    Extech EX520 - Extech Instruments Corporation

    Designed to withstand harsh environments and usage, the meter's rugged, double-molded housing is IP67-rated (waterproof and dustproof) and drop-tested to 6 ft. The large, illuminated LCD displays 4-digit readout (to 6,000 counts). The EX520 offers various must-have measurements. The meter features 0.09 percent accuracy and a CAT IV 600-volt safety rating, protecting users even on outdoor wiring. Product includes a 3 year warranty, double molded test leads, 9V battery, magnetic hanging strap, temperature probe and carrying case.

  • Fast Photo-Electric Tester

    LS616S - Lisun Electronics Inc.

    The machine is made up of three main parts: measuring circuit of electric parameter, measuring circuit of photometric parameter and circuit of CPU system. Voltage and current signals are amplify and sent to high speed A/D transform, and the transform digital signals are sent to microprocessor, the input current signals of brightness detector are sent to A/D transform via I/V convert, and the transform digital signals are sent to microprocessor. Microprocessor processing the input photometric and electric data, it automatic switch between different range and calculate and display the data in the mean time.

  • Engineering Design & Development

    TPS Associates, Inc.

    TPSA has over 20 years of experience in Engineering Design & Software Development including:Hardware & Software DesignOTPS Acquisition SupportSystems Installation & SupportAircraft Modification/CertificationEngineering Studies & AnalysesFunctional & Systems TestingIndependent Verification & Validation (IV & V)Test Program Set EngineeringReliability & Maintainability (R&M)Engineering Drawings & DataConfiguration Data ManagementReverse EngineeringRequirements AnalysisSupport Equipment (SE)Aircraft Launch & Recovery Engineering (ALRE)Engineering Change Proposal (ECP) ReviewTechnology Insertion (TI)PDR, CDR, FAT, Techeval, OSV Support