  • Sensor Products: Weld Force Gage

    90061 - HITEC Sensor Solutions Inc.

    Model 90061 is a self-contained, portable measurement system which allows auditing of the pinch force generated between the electrodes of resistance spot welders. Resistance welding uses a pair of electrodes to clamp two base metals firmly together prior to and during application of electrical current. Poorly clamped parts result in a defective joint. A correctly clamped assembly aids in reducing the resistance in the joint and allows the current flow to properly heat the base metals to weld the part.

  • Vehicle Calorimeters, Emissions Test Systems, and Instrumentation

    TetraTek Products, Inc.

    When you examine a TetraTek Automotive Test System you will know you have seen the future. Simply stated, we offer the most carefully considered, best engineered, and most reliable systems available. Everything from fully integrated Drive-in Emission test rooms with four-wheel dynamometers, solar simulation, high volume variable air flow, and temperature and humidity control to individual pieces of equipment and subsystems needed to upgrade existing facilities.

  • Strength Testing

    Sataton Instruments Technology CO., Ltd

    Air permeability tester is professional designed to determine the permeability of materials to air. By testing the rate of flow of air passing perpendicularly through a given area of tested sample under a given pressure over a given time period, the tester can provide results of air permeability performance by calculation the indices. The air permeability testing instrument is applicable to many type of materials, including industrial fabrics, nonwovens, made-up textiles, paper and board, foam and other materials.

  • Hall Effect Measurement system

    HMS-3300 - ECOPIA

    Magnetic flux density : 0.55Tesla (+/-0.03T)Gap distance between both round magnets : 26mm / Round magnet diameter : 50mmMeasurable temp : RT ~ 300℃(model# HT55T3). Resolution : 0.1℃(Model# HT55T5 : RT ~ 500℃)Both HT55T3 and HT55T5 are only capable of using with HMS-3000 main body.(Not compatible with HMS-5000 )- You can flow purge gas into small chamber and measure hall effect at the same time. Gas control valve can be installed as an option.

  • FlowQuest Acoustic Current Profilers

    LinkQuest Inc.

    FlowQuest is a line of Acoustic Current Profilers manufactured by LinkQuest Inc., a company renown for its innovation, capability and product quality. The FlowQuest current profilers are ideal for measuring currents and flows in oceans, harbors, lakes and rivers. With its capability for significantly longer range, standard deepwater depth rating and seamless integration with third-party sensors and LinkQuest acoustic modems, the FlowQuest system is not just a current profiler. It also serves as a focal point for your underwater deployments.

  • Wind Sensors

    FT742 - FT Technologies

    The FT742 measures wind speeds up to 75 m/s. Its innovative design incorporates a series of “turbulators” which condition the air flow to deliver our highest levels of accuracy yet. Available in four mounting options, the Flat Front (FF) and Pipe Mount (PM) are typically used in wind turbine control and the Direct Mount (DM) in meteorological applications. The Surface Mount (SM) has been specifically designed for OEM integration and for use on UAVs/drones.

  • Dynamic Dilution Calibrator

    Model T700 - Teledyne Advanced Pollution Instrumentation

    The Model T700 is a microprocessor based calibrator for precision gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations using up to 4 gas sources.The Model T700 can be equipped with an optional UV ozone generator for accurate, dependable ozone calibrations, and to enable production of NO2 when blended with NO gas in the included, internal gas phase titration (GPT) chamber. An optional photometer allows even more precise control of the ozone generator giving accurate and dependable ozone calibrations and enhanced GPTs. To ensure the highest accuracy of NO2 output, the T700 with the photometer option can measure the ozone concentration prior to performing a GPT. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the Model T700, covering time periods up to a year.

  • Trace-Level Photometric Ozone Calibrator

    Model T703U - Teledyne Advanced Pollution Instrumentation

    The Model T703U is a microprocessor controlled ozone calibrator for precision gas analyzers. Expanded ozone audit levels have created a need for precise ozone calibration well below the capabilities of standard calibrators. The Model T703U is designed to meet the requirements of ultra-low ozone production.In addition to a high range with similar performance to the Model T703, the Model T703U has the capability to generate ozone in a low range, or "fractional" mode, for producing ozone levels down to 3 ppb, with exceptional accuracy. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperature and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703U, covering time periods up to a year.

  • Hysteresis Dynamometers

    HD Series - Magtrol Inc.

    16 Standard Models with Maximum Torque from 2.5 ozin to 500 lbin (18 mNm to 56.5 Nm)Hysteresis Braking System: Provides precise torque loading independent of shaft speedMotor Testing from No Load to Locked RotorAccuracy: 0.25% to 0.5% (Full Scale)Air Flow Sensor: For protection against overheating and operator errorStandard Torque Units: English, Metric and SIBase Plate: Available in long or short versionsCustom Dynamometers: for special torque and speed requirementsEasy Calibration

  • 10 Digit Rate/Batch Counter

    CS2-MC - Chuan Sheng Electronics Co., Ltd.

    The CS2-MC provides dual input(A/B phase) and display with high speed, counting, control and communication (Modbus RTU mode) of Pulse from encoder, proximity switch, photo switch or flow meter for counting, length and position control. There are 3 external control input (DI) in standard and the optional 4 Relay, 1 Analogue, and RS485 port available.The relays are also support N, C, R, E mode and Hi/Lo energized for batch / totalizer and position control.

  • Lab-Type Environmental Stress Screening Chambers

    ESS5/11 SERIES - ESPEC North America, INC.

    The ESS5/11 Series provides the unique capability of stress screening products in a small, lab-type chamber. Pre-qualification for ESS, troubleshooting, and small scale ESS programs would all benefit from high air flow, high change rate testing in this compact design. This series can accommodate up to six product drawers from our standard ESS systems. Other features include non-CFC/HCFC design, and wide variety of control systems, refrigeration system sizes, and product fixturing options.

  • Vane Anemometer

    AM-4836V - Rinch Industrial Co.,Limited

    Parameters measured: Wind speed, Flow, Beaufort Scale, Wave, Temp., wind directionRange:Wind speed: 0.4-30.0m/s1.4-108.0km/h80-5910ft/min0.8-59.3 knotsFlow: 0.004-9999 m³/min0.013-9999 ft³/minB. Scale: 0-12 forceWave: 0-14mDirection indicator: 16 ways (the resolution is 22.5º)Temp. : 0-60℃ / 32-140℉Accuracy: ±2%n+2Resolution: 0.1/1PC interface: RS232C (Cable & software are optional)Can memorize 50 group dataAuto power offPower supply: 4x1.5V AA A (UM-4) batteryBattery indicator: low battery indicatorDimensions: 156x67x28mm

  • Analyzers & Systems

    Guided Wave

    The optical or spectrum analyzer is the brain which transforms the signal collected by the sample interface into actionable information. Guided Wave sample interfaces (probes, flow cells) are designed for use with NIR or UV-Vis fiber optic coupled analyzers. They are designed to be rugged and reliable in harsh chemical and physical process conditions while providing optimal light transmission for long-term reliable measurements. More information is available about specific analyzers on each product page or on the process analyzer product overview.

  • Ozone Gas Delivery Systems

    MKS Instruments

    MKS ozone gas delivery systems provide field-proven, high concentration, ultra-clean ozone generation for advanced thin film applications such as Atomic Layer Deposition (ALD), Chemical Vapor Deposition (CVD), Tetraethyl Orthosilicate (TEOS)/Ozone CVD (HDSACVD), contaminant removal and oxide growth. Gas delivery models have integrated ozone concentration monitoring, flow control, and power distribution. Additional system options include safety monitoring, status indicators and ozone destruction capability.

  • Pressure Sensor Kit for Changing Ranges

    DP15TL - Validyne Engineering

    The wide range of diaphragms furnished eliminates expensive stocking of several transducers and offers the versatility of the differential type bi-directional transducer at a very low cost. The broad line pressure capability of this unit makes it useful in almost every laboratory application from flow to level measurement, vacuum to 3000 PSIG. The high output, when used with a carrier system such as the Model CD15 Sine Wave Carrier Demodulator or the CD12 Transducer Indicator, provides resolution equal to many secondary standard units.