Showing results: 586 - 600 of 1134 items found.
-
FM-4 -
Parker Hannifin Corp.
The FM-4 Series PFA/PTFE Flowmeter is designed for ultra-high purity applications where precise flow control of liquids is required. It offers extreme corrosion resistance and uses compression technology for leak-free operation (up to 120 psig).
-
TST3PK -
Power Probe Group, Inc.
Mini Probe: Easy to use plug-in style current testers, simple way to verify current flow in a socket.- Complete Kit – TST3PK- USB PROBE – TSTUSB- ACC PROBE – TST12V- VAC PROBE – TST110V
-
PCE Instruments
An anemometer measures wind speed. Indoors, an anemometer measures air speed, air velocity or air flow. The air flow rate in buildings is often measured in cubic feet per minute (CFM) using anemometers to assess the performance of heating, ventilation and air conditioning (HVAC) systems and equipment.PCE Instruments (PCE) offers a variety of anemometer products to meet the air flow and wind speed measurement needs of professionals in industries such as HVAC, construction, marine and wind power and energy, including hot-wire anemometers, thermo anemometers, pitot tube anemometers, cup anemometers, rotating vane anemometers and impeller anemometers with capture hoods. Plus, hobbyists such as boating, sailing and water sports enthusiasts utilize PCE's accurate and affordable digital handheld anemometer and portable mini anemometer product offerings to evaluate outdoor wind conditions. For meteorological measurements, please see PCE's weather station products.
-
Nex Flow Air Products Corp.
Nex Flow® Air amplifiers are compact, low cost air flow “movers” that are virtually maintenance free. Applications include the venting of fumes and smoke, conveying of low weight materials, and entraining a high volume of air to cool, blow off, and dry. Air Amplfiiers use the “Coanda effect” to draw in the surrounding atmosphereic air while consuming only aminimal amount of compressed air. These products can amplify airflow up to 17 times (depending on the size) resulting in dramatcally reduced levels of noise. Air Amplifiers (also called Air Movers) draw in atmospheric air from the back of the unit as well as having downstream entrainment further amplifying the flow. They are used for cooling and venting. While the force produced for blow off decreases as the amplifier outlet diameter increases, these Air Movers are ideal for cooling because of the high velocity outlet fow and and are much more effective for cooling compaed to air nozzles.
-
Model DS-10 -
Malcom Co.,Ltd.
Putting it a conveyor to flow through a solder bath to obtain information needed to manage it. The created temperature profile makes it possible to monitor the 50ms sampling temperature of the preheat and solder temperature sensors in addition to the conventional management items.
-
TGPR-0800 -
Gemini Data Loggers Ltd.
A current input data logger that is supplied uncased so that it can be built into custom applications.The TGPR-0800 can be used to record the output from a number of industry standard 4-20mA sensors. Common applications include pressure and flow rate monitoring.
-
AMETEK Drexelbrook
Ultrasonic technology is a perfect choice for level applications that require low cost, non-contact measurement of liquids and slurries for level, distance, volume and open channel flow. These products have excellent accuracy and will handle measurements up to 30’.
-
WXU -
CKD Corporation
An integrated unit that integrates the flow sensor and valve of the circulation circuit of the cooling water.The complicated piping design around water and the number of man-hours for piping work are greatly reduced, and the footprint is reduced by 80% to save space in the system.
-
Pulse Electronics
Is a passive two-terminal electrical component that stores energy in a magnetic field when electric current flows through it.
-
SEMulator3D -
Coventor
SEMulator3D® is a powerful 3D semiconductor and MEMS process modeling platform that offers wide ranging technology development capabilities. Based on highly efficient physics-driven voxel modeling technology, SEMulator3D has a unique ability to model complete process flows. Starting from input design data, SEMulator3D follows an integrated process flow description to create the virtual equivalent of the complex 3D structures created in the fab. Because the full integrated process sequence is modeled, SEMulator3D has the ability to predict downstream ramifications of process changes that would otherwise require build-and-test cycles in the fab.
-
MF Series -
EKO Instruments Co., Ltd.
EKO Heat Flow Sensors are applied to measure the heat flow or thermal conductivity in materials and radiative IR flux emitted by body surfaces. The sensors are suitable for indoors applications, some models made for outdoors purposes and are available in different sizes and thickness. All sensors are extremely flat, which is a big advantage considering the minimum interference with the conditions of the testing area the thermal dynamics. Since sensor foils are relatively flexible those can easy be applied on curved surfaces and can be used in different applications to measure the performance of insulating materials in refrigerators, container walls, pipes, building constructions, etc.
-
FFF -
Wyatt Technology
Is a separation technique where a field is applied to a fluid suspension or solution pumped through a long and narrow channel, perpendicular to the direction of flow, to cause separation of the particles present in the fluid, depending on their differing "mobilities" under the force exerted by the field.
-
TG010 -
TESTEX Testing Equipment Systems Ltd.
Geotextile Water Permeability Tester, to determine the constant-head water flow capacity (water permeability) within the plane of a geotextile or geotextile-related product, is measured under varying normal compressive stresses, typical hydraulic gradients and defined contact surface.
-
6U VME64x 395-x Mini -
W-IE-NE-R, Plein & Baus GmbH
The VME395-x mini crate series offers hot-swappable, redundant power supplies in a 9 slot, compact but modular designed VME64x chassis. A front-side-plug high performance DC fan is used for cooling with front to rear air flow.
-
CENTER 332 -
Center Technology Corp.
Air Velocity Measurement: m/s, km/hr, ft/min, MPH, Knots & Build In Temperature ºC / ºF, Humidity %RH, Air Velocity Compensation In Atmospheric Pressure, Air Flow Measure: CMM, CFM, Telescoping Hot Wire Probe