Showing results: 226 - 240 of 475 items found.
-
AMMS-100 XRF -
Focused Photonics Inc.
The system integrates X-ray fluorescence for metal analysis up to 30 elements and a beta-ray attenuation model for particulate mass monitoring. But module will be using the same sample moving sequentially across the detector and would be significantly effective in industry emission tracing.
-
SkyScan -
Xtreme Research Corp.
The SkyScan detects electromagnetic emissions from individual lightning strokes, and can be detected at long range by use of ad hoc sensors. It is a hand-held instrument with an electronic system to detect the presence of lightning/thunderstorm activity occurring within 40 miles of your location.
-
Ono Sokki
Various types of test system as follows can be built up in combination with measurement control equipment and peripheral instruments (fuel flow meters, actuators, temperature control device, combustion analysis system, ECU monitor, OBD, sound and vibration measurement instruments, emission analyzer, smoke meter etc.)·Traveling fuel economy test·Gas emission test·Output performance test·Deterioration/endurance test·Combustion analysis·Sound source probing
-
atmosFIR -
Protea Ltd
atmosFIR runs a Standard Analysis Mode with fixed acquisition parameters and chemometric analysis for common emission gases. This makes it incredibly simple to use even for users with no extensive FTIR background. Further analysis methods can be uploaded by the trained user or remotely by Protea.
-
Labfon Equipment Inc.
A fluorometer, fluorimeter or fluormeter is a device used to measure parameters of visible spectrum fluorescence: its intensity and wavelength distribution of emission spectrum after excitation by a certain spectrum of light.[1] These parameters are used to identify the presence and the amount of specific molecules in a medium.
-
MPR, MDA series -
Microwave Factory Co,Ltd.
MPR, MDR series provides low noise, high gain and wideband to improve dynamic range for emission testing. We also offer customized model for variable requirments.. Example 30M-1000MHz with band-pass filter Amprifier unit for connecting antenna directly
-
MRC ltd.
Flame Photometer applies the emission spectrum as the basic principle, which uses the flame heat and excites part of the atoms in alkaline earth metal. The atoms receive energy and transfer it to the old energy level. When the atom is at a normal energy level it releases the energy.
-
TDK HRN-0118 -
TDK RF Solutions Inc.
The TDK HRN-0118 broadband horn antenna (1 GHz to 18 GHz) is designed specifically for radiated emissions and immunity measurements in EMC test environments. The HRN-0118 horn antenna provides optimal performance over the frequency range of 1 GHz to 18 GHz.
-
IMR Environmental Equipment, Inc.
Flue Gas Analyzers for residential and commercial applications (HVAC, heating contractors). We also offer hand held Combustion Gas Analyzers and professional Flue Gas Analysis instruments in rugged boxes that can measure combustion efficiency and the emissions of furnaces, boilers etc.
-
Langer EMV-Technik GmbH
We carry out standard measurements according to BISS/IEC and analysis of the interference immunity and interference emissions of ICs during development.With the targeted EMC analysis, we uncover weak points in the ICs so that the IC developer can use them to develop improvements for the product
-
Physical Acoustics Corp.
Physical Acoustics’ sensors are built to "listen" to high frequency signals. Much like a highly-sensitive “ear,” Acoustic Emission sensors interpret the material’s “voice” into usable AE waveforms. Additionally, AE sensors help understand how materials behave in their natural setting.
-
Seibersdorf Labor GmbH
The PLA-R and PLA-T are active, battery powered receive and transmit loop antennas for the frequency range 9 kHz - 30 MHz intended for radiated emission testing (PLA-R) and site validation: Normalized site Attenuation, Shielding Effectiveness (PLA-SET consisting of PLA-R and PLA-T)
-
7Layers, Inc.
Electromagnetic compatibility (EMC) must be demonstrated for all devices with integrated radio components for approval in almost every country in the world. EMC tests examine whether the electromagnetic emissions from your product are within the specified limits and whether your product and its functionalities themselves are not negatively influenced by electromagnetic emissions. We offer EMC tests for modules and end products with integrated radio technology as well as IT and IoT products. Our accredited EMC test laboratories are equipped to test almost all modern radio technologies, and our EMC experts have many years of experience in this area. With us, your modern radio products are on the safe path to the global market.
-
AA-Ultrasonic -
IPEC Ltd.
The AA-Ultrasonic acoustic probe is designed for use on air insulated terminations where a clear sound path between the electrically stressed insulation and the probe is present. The sensor is extremely sensitive and can detect activity below 10pC. The probe has a magnetic base to allow coupling to steel enclosures and a swivel head as so the detecting sensor can be aimed directly at the HV point. Corona in air and surface tracking can seriously damage high voltage insulating surfaces in a way that will ultimately lead to flashover and complete failure of the insulator. This discharge activity creates acoustic emission that can be detected using a high frequency sensor. The magnitude of the acoustic emission is indicative of the degree and severity of the discharge activity.
-
Com-Power Corporation
Log Periodic antennas allow quick sweep measurements without a band break. This feature makes it convenient to use the Log Periodic antenna with a automated emissions or immunity measurement system. The size of the antenna also allows it to be used in a small area like a shield room.