Showing results: 436 - 450 of 897 items found.
-
Z5411 -
Copper Mountain Technologies
*Z5411 Calibration Kit, * Frequency Range: up to 54 GHz, * Impedance: 50 Ohm, * Connector Type: 2.4 mm female.
-
T4311 -
Copper Mountain Technologies
*T4311 Calibration Kit, * Frequency Range: up to 40 GHz, * Impedance: 50 Ohm, * Connector type: 2.92 mm female.
-
CK521A -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
CK520A -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
CK562A -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
CK564A -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
CK058F -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
CK058M -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
RK-410FS -
ADLINK Technology Inc.
*EIA RS-310C 19" rackmount standard*17.8 inch (451 mm) short depth*Three 5.25" and one 3.5" shock-resistant drive bays*Two front accessible USB connectors*Adjustable hold down bar for cards
-
YAV90Q04 -
6TL Engineering
The interface YAV90Q04 permits to connect two YAV90096 boards to one 192-Signal contacts Quadrapaddle module. As the Mini-D 50 connectors let 2 free pins (1 and 26), these pins are interconnected to a test point, with the possibility of be grounded. Cable P/N J6200540: Mini-D-50 to Mini-D-50 IDC connectors with 400 mm flat cable.
-
TD-24S-AC -
Taylor Dynamometer, Inc.
Weight Capacity: 30,000 lb (13,608 kg) per axleRoll Brakes: Pneumatically-actuated discShipping Weight: 19,700 lb (8,936 kg)Capacity: 517 hp at 30 mph (385 kW at 48 kph)Rolls: 24 by 34 in. (610 by 864 mm) 4 front fixed rollsPit Required Depth: 26 in. (660 mm)
-
AX7300T -
Axiomtek Co., Ltd.
*Combinations for 1 x slim CD-ROM & 1 x standard FDD or 1 x slim CD-ROM & 1 x 3.5" HDD (Storage devices are not included)*Dimensions (W x D x H): 5.87" (149 mm) x 5.51" (140 mm) x 1.66" (42.1 mm) (Storage devices are not included)
-
TD-36S -
Taylor Dynamometer, Inc.
Weight Capacity: 30,000 lb (13,608 kg) per axleRoll Brakes: Pneumatically-actuated discShipping Weight: 6,600 lb (2,994 kg)Capacity: 550 hp at 45 mph (410 kW at 72 kph)Rolls: 36 by 31 in. (914 by 787 mm)Pit Required Depth: 35 in. (889 mm)
-
TD-24S -
Taylor Dynamometer, Inc.
Weight Capacity: 30,000 lb (13,608 kg) per axleRoll Brakes: Pneumatically-actuated discShipping Weight: 8,700 lb (3,946 kg)Capacity: 550 hp at 35 mph (410 kW at 56 kph)Rolls: 24 by 34 in. (610 by 864 mm) 4 front fixed rollsPit Required Depth: 27 in. (686 mm)
-
CM-51-EC -
Taylor Dynamometer, Inc.
Weight Capacity: 25,000 lb (11,340 kg) per axleRoll Brakes: pneumatically-actuated discShipping Weight: 8,340 lb (3,783 kg)Capacity: 622 hp at 45 mph (464 kW at 72 kph)Rolls: 20 by 36 in. (508 by 915 mm) long4 front fixed rolls, 2 rear rolls fixed toaccommodate axle spreads from48 to 60 in. (1,219 to 1,524 mm)tandem centersPit Required Depth: 25 in. (635 mm)