Showing results: 16 - 30 of 305 items found.
-
S930702B -
Keysight Technologies
S930702B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 26.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930702B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
S930705B -
Keysight Technologies
S930705B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 50 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930704B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
S930709B -
Keysight Technologies
S930709B enables fast and accurate active device modulation distortion characterization under modulated stimulus conditions up to 90 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S930709B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
S930701B -
Keysight Technologies
S930701B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 13.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930701B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
S930712B -
Keysight Technologies
S930712B enables fast and accurate active device modulation distortion characterization under modulated stimulus conditions up to 125 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S93072B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
S930704B -
Keysight Technologies
S930704B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 43.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930704B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
S95070B -
Keysight Technologies
S95070B software enables fast and accurate active device modulation distortion characterization under modulated stimulus conditions up to 53 GHz. The wide dynamic range and vector error correction of the PXI VNA results in an extremely low residual EVM from the test setup, giving you a complete picture of your device’s performance without test system interference. S95070B software measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals through spectral correlation between the input and output spectrum, without doing demodulation. Integration with the PXI VNA’s measurement flexibility enables you to do quick modulation distortion measurements along with traditional VNA tests.
-
MCH Instruments Co.,Ltd.
Feature:*Auto range*Single/Repeating measuring*Four-terminal measuring*Percentage error three steps selectable*Dual display
-
S960704B -
Keysight Technologies
The Keysight S960704B modulation distortion software application enables fast and accurate active device modulation distortion characterization under modulated signal conditions up to 20 GHz. The wide dynamic range and vector error correction of the ENA-X yield an extremely low residual EVM of the test setup, delivering a complete picture of your device’s signal distortion performance without test system interference. S960704B software measures EVM, NPR, ACPR, and decomposes linear and nonlinear signals by spectrally correlating input and output spectrum without needing to demodulate. Integration with the ENA-X measurement flexibility enables quick modulated signal distortion measurements along with traditional VNA tests.
-
S95087B -
Keysight Technologies
Easily set up and calibrate swept intermodulation distortion measurements (IMD) using the S95087B software application with the M980xA PXI VNA.
-
S960707B -
Keysight Technologies
The S960707B modulation distortion software application provides nonlinear DUT behavior tests (EVM, NPR, and ACPR) under modulated stimulus conditions.
-
S930713B -
Keysight Technologies
S930713B enables fast and accurate active-device modulation distortion characterization under modulated stimulus conditions up to and beyond 125 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S930713B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
S94571B -
Keysight Technologies
Load pull capability for modulation distortion measurements up to 50 GHz for export controlled countries
-
S97087B -
Keysight Technologies
Easily set up and calibrate swept intermodulation distortion measurements (IMD) measurements using the S97087B software application with the P50xxA/B Streamline Series VNA
-
AC1000A -
Aim-TTi
Provides an EN61000–3–2 compliant source1000W power capability at 230VUp to 4·4A rms load current and up to 10A peak currentsComprehensive overload protectionConnection via standard power connectors