Filter Results By:

Products

Applications

Manufacturers

Showing results: 286 - 300 of 304 items found.

  • Digital (1kV up) H.V. Insulation Tester

    6213A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps) - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV,    3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV,    9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bar-graph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present (>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.● Calculates Dielectric Absorption Ratio (DAR) automatically.● Calculates Polarization Index (PI) automatically.

  • Digital (1kV up) H.V. Insulation Testers

    6213A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps) - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV,    3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV,    9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bar-graph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present (>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.● Calculates Dielectric Absorption Ratio (DAR) automatically.● Calculates Polarization Index (PI) automatically.

  • Coating Thickness Gauge

    NOVOTEST TP-1 - NovoTest

    Portable Coating Thickness Gauge NOVOTEST TP-1 – device for operative non-destructive testing of coating thickness in compliance with ISO 2808 with high measurement accuracy.Coating thickness gauge is designed to test:thickness of various thick protective coatings on various metals and alloys;thickness of paint and other dielectrics – radioabsorbing, mastic, teflon, plastic, electroplating coatings on steel;thickness of electroplating and paint coatings on non-ferromagnetic alloys and non-ferrous metals;thickness of bitumen and other thick coatings on various metals and alloys;as well as relative humidity, air temperature, surface temperature, dew point temperature and difference between surface and dew point temperatures, estimate the depth of grooves and the surface roughnessElectronic thickness gauge – device which widely used in shipbuilding and automotive industries for measuring of the thickness of paint, in order to test the quality of products, also it used for determining technical condition of the tested objects.

  • High-Voltage Test Hood

    LX-HVE600 - LXinstruments GmbH

    The bright test room with a ball-bearing cover is designed for high production quantities. Thanks to the easily exchangeable exchangeable plate, retrofitting for testing different products is also a simple task. Product properties: External dimensions (W * D * H) approx. 640 * 716 * 640mm Usable test space (W * D * H) approx. 450 * 500 * 460mm Contacting Installation space approx. 100mm high under removable plate Dielectric strength min 10kV Application area up to 2000m above sea level Pollution degree 1 without condensation Standard conformity EN50191 / EN61010-1 Schmersal safety switch AZM161 with guard locking Lid is supported by ball bearings for high number of cycles, the bearings can be easily exchanged for servicing Optionally available, Not included in the price: - Red / green signal light - Mobile substructure trolley with 19 "

  • High-Voltage Test Hood

    HVE900 - LXinstruments GmbH

    The large, bright test room with a ball-bearing cover is designed for high production quantities. Thanks to the easily exchangeable exchangeable plate, retrofitting for testing different products is also a simple task. Product properties: External dimensions (W * D * H) approx. 940 * 716 * 640mm Usable test space (W * D * H) approx. 750 * 500 * 460mm Contacting Installation space approx. 100mm high under removable plate Dielectric strength min 10kV Application area up to 2000m above sea level Pollution degree 1 without condensation Standard conformity EN50191 / EN61010-1 Schmersal safety switch AZM161 with guard locking Lid is supported by ball bearings for high number of cycles, the bearings can be easily exchanged for servicing Optionally available, Not included in the price: - Red / green signal light - Mobile substructure trolley with 19 "

  • Digital H.V. Insulation Tester(10kV)

    6310 IN - Standard Electric Works Co., Ltd

    ● 2 Lines × 16 Characters LCD● Microprocessor-controlled● Tests insulation resistance up to 20 TΩ● 4 Insulation test voltages: 1000V, 2500V, 5000V, 10000V● AC / DC Voltmeter (30~600V)● Short-circuit current up to 5mA● PI (Polarization Index) indication● DAR (Dielectric Absorption Ratio) indication● Auto-ranging on all insulation ranges● Optical USB to RS-232 data transmission● Well isolated from contact● Well protected from surges● 2 built-in optical LEDs for data transfer● Visual and audio warning of external voltage presence (≥30Vac or ≥30Vdc)● Auto-hold function to freeze reading● Overload protection● Adjustable testing duration: 1~30 minutes● Internal memory for data storage● Displays testing duration for insulation measurement● Auto-off function● 200 measurement results can be saved in memory and recalled on

  • Digital H.V. Insulation Tester(5kV)

    6305A IN - Standard Electric Works Co., Ltd

    ● 2 Lines × 16 Characters LCD● Microprocessor-controlled● Tests insulation resistance up to 10 TΩ● 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V● AC / DC Voltmeter (30~600V)● Short-circuit current up to 5mA● PI (Polarization Index) indication● DAR (Dielectric Absorption Ratio) indication● Auto-ranging on all insulation ranges● Optical USB to RS-232 data transmission● Well isolated from contact● Well protected from surges● 2 built-in optical LEDs for data transfer● Visual and audio warning of external voltage presence (≥30Vac or ≥30Vdc)● Auto-hold function to freeze reading● Overload protection● Adjustable testing duration: 1~30 minutes● Internal memory for data storage● Displays testing duration for insulation measurement● Auto-off function● 200 measurement results can be saved in memory and recalled on

  • Digital H.V. Insulation Tester(5kV)

    6305 IN - Standard Electric Works Co., Ltd

    ● High contrast OLED display● Microprocessor-controlled● Tests insulation resistance up to 10 TΩ● 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V● AC / DC Voltmeter (30~600V)● Short-circuit current up to 5mA● PI (Polarization Index) indication● DAR (Dielectric Absorption Ratio) indication● Auto-ranging on all insulation ranges● Optical USB to RS-232 data transmission● Well isolated from contact● Well protected from surges● 2 built-in optical LEDs for data transfer● Visual and audio warning of external voltage presence (≥30Vac or ≥30Vdc)● Auto-hold function to freeze reading● Overload protection● Adjustable testing duration: 1~30 minutes● Internal memory for data storage● Displays testing duration for insulation measurement● Auto-off function● 200 measurement results can be saved in memory and recalled on display

  • Digital H.V. Insulation Tester(5kV)

    6304 IN - Standard Electric Works Co., Ltd

    ● 2 Lines × 16 Characters LCD● Microprocessor-controlled● Tests insulation resistance up to 10 TΩ● 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V● AC / DC Voltmeter (30~600V)● Short-circuit current up to 1.9mA● PI (Polarization Index) indication● DAR (Dielectric Absorption Ratio) indication● Auto-ranging on all insulation ranges● Optical USB to RS-232 data transmission● Well isolated from contact● Well protected from surges● 2 built-in optical LEDs for data transfer● Visual and audio warning of external voltage presence (≥30Vac or ≥30Vdc)● Auto-hold function to freeze reading● Overload protection● Adjustable testing duration: 1~30 minutes● Internal memory for data storage● Displays testing duration for insulation measurement● Auto-off function● 200 measurement results can be saved in memory and recalled on display

  • Variable Frequency AC Resonant Test System

    HDXZ-270kVA/270kV - HD Power Test Equipment Co.ltd

    HDXZ-270kVA/270kV Variable Frequency AC Resonant Test System is applied for AC dielectric test for electric equipment.1. 10kV/300mm2 cable 3km AC withstand test,capacitance≤1.1265uF,test frequency:30-300Hz, test voltage 22kV, test time 5min;2. 35kV/300mm2 cable 1km AC withstand test,capacitance≤0.1945uF,test frequency:30-300Hz, test voltage 52kV, test time 60min;3. 110kV/630mm2 cable 0.2km AC withstand test,capacitance≤0.0368uF,test frequency:30-300Hz, test voltage 128kV, test time 60min;4. 110kV/63000kVA Transformer AC withstand test,capacitance≤0.02uF,test frequency:30-300Hz, test voltage below 160kV, test time 1min;5. GIS 110kV, Switching busbar and other substation equipment, AC withstand test,test frequency:30-300Hz, test voltage below 265kV, test time 5min

  • Semi-Rigid Assemblies

    Teledyne Defense Electronics Storm Microwave

    Storm Products has been producing high performance semi-rigid interconnects for over 20 years for a variety of markets, including: defense, telecom, wireless and test & measurement. Experienced in:- Cable sizes from 0.034" to 0.500"- Solid PTFE dielectric and high performance tape wrapped products- Wide variety of standard connector styles: MCX, SMA, SMB, SMC, TNC, N, 7/16, SC, and HN- Years of experience on blindmate connector styles: OSP GPO, GPPO, and GMSSpecialized experience in:- Applications where phase stability is critical- low intermod interconnects- High power designsManufacturing equipment:- Automated bending equipment and optical comparators - Programmable thermal chambers for pre-conditioning formed cables- Specialized assembly and soldering equipment for high volume applications- Automated network analyzers through 50GhzDue to the custom nature of formed semi-rigid cable assemblies, additional information is required before providing a quotation for your requirement.

  • Digital H.V. Insulation Tester(15kV)

    7016 IN - Standard Electric Works Co., Ltd

    ● Protection class: IP66 (Lid closed)● Test insulation resistance up to 30TΩ (30000GΩ).● Short-circuit current up to 5mA● Microprocessor controlled.● 30 insulation test voltages : 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 12.5kV, 13kV, 13.5kV, 14kV, 14.5kV, 15kV● AC/DC voltmeter (600V).● PI (Polarization Index) indication.● DAR (Dielectric Absorption ratio) indication.● Auto-ranging on all insulation ranges.● Backlight function.● Menu driven.● Visual and audible warning if external voltage is present. (≥30Vac or ≥30Vdc)● Auto-hold function to freeze the reading.● Overload protection.● Adjustment for testing time (duration) : 1~30 minutes● Auto-off.● Calendar.● Optical USB to RS-232 data transmission.● 200 measurement results can be saved in the memory and recalled on the display.● Safety standard : EN 61010-1 CAT IV 600V EN 61010-2-030 EN 61326-1

  • Digital H.V. Insulation Tester(12kV)

    7012 IN - Standard Electric Works Co., Ltd

    ● Protection class: IP66 (Lid closed)● Test insulation resistance up to 20TΩ (20000GΩ).● Short-circuit current up to 5mA● Microprocessor controlled.● 24 insulation test voltages :   500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV,   3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV,   6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV,   9.5kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV ● AC/DC voltmeter (600V).● PI (Polarization Index) indication.● DAR (Dielectric Absorption ratio) indication.● Auto-ranging on all insulation ranges.● Backlight function.● Menu driven.● Visual and audible warning if external voltage is present. (≥30Vac or ≥30Vdc)● Auto-hold function to freeze the reading.● Overload protection.● Adjustment for testing time (duration) :  ● 1~30 minutes● Auto-off.● Calendar.● Optical USB to RS-232 data transmission.● 200 measurement results can be saved in the memory and recalled on the display.● Safety standard : EN 61010-1   CAT IV 600V   EN 61010-2-030    EN 61326-1

  • Digital (1kV up) H.V. Insulation Testers

    7015 IN - Standard Electric Works Co., Ltd

    ● Protection class: IP66 (Lid closed)● Microprocessor controlled.● 2 Lines x 16 characters, large intelligent LCD module.● 30 insulation test voltages : 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 12.5kV, 13kV, 13.5kV, 14kV, 14.5kV, 15kV● AC/DC Voltmeter.● PI (Polarization Index) indication.● DAR (Dielectric Absorption ratio) indication.● Auto-ranging on all insulation ranges.● Current measurement.● Backlight function.● Menu driven.● Visual and audible warning if external voltage is present. (≥30Vac or ≥30Vdc)● Short-circuit current up to 5mA● Auto-hold function to freeze the reading.● Overload protection.● Adjustment for testing time (duration) : 1~30 minutes.● Calendar.● Indication memory for data storage.● Optical USB to RS-232 data transmission.● Auto-off.● 200 measurement results can be saved in the memory and recalled on the display.

  • High Voltage Surge Current Monitors

    HVSCM - Test Electronics

    Designed to be used with the Model HVST High Voltage Surge tester. The Surge Current Monitor allows simultaneously surge testing 20 units. The Surge Current Monitor monitors the current going through each unit under test at the time of the surge. If a unit under test breaks down or leaks, the Surge Current Monitor will identify the bad unit by lighting the corresponding LED. The most important features of the surge tester are its ability to test the entire winding insulation system. A high voltage surge generates turn to turn, coil to coil, and phase to phase voltage stress, as well as ground insulation stress. When used as a dielectric test, accurate voltage readings are essential. The HV Surge Tester monitors the voltage directly across the winding under test. In production testing we expect that most of the time the devices will pass. In the event that one should fail, the failed device would be removed and then all the parts would have ot undergo another surge test. Since most devices pass most of the time, simultaneous surge testing can be a real time saver.

Get Help