Filter Results By:

Products

Applications

Manufacturers

Showing results: 271 - 285 of 304 items found.

  • HV Power & Transient Isolators

    B-1020-C - ROSS ENGINEERING CORPORATION

    These supply 120V or 240V AC continuous power for equipment that must operate while at a high voltage to ground or power source. For example, a fiber optic transmitter at the HV level for waveforms to be received and measured or recorded by grounded instrumentation might be powered by an isolation transformer secondary to primary either insulated by potting, oil or air. The low dielectric constant of air insulation provides lower capacitive coupling between the secondary and the primary or ground than would solid or oil insulation. The lower capacitance provides better isolation both at line frequency and especially at high frequency voltages such as lightning or switching transients.

  • Integrated I-V Test Systems

    OAI

    The OAI Integrated I-V Test System is perfect for R&D as well as production, the OAI Integrated I-V Test System delivers extremely accurate solar cell performance measurement. OAI’s advanced fully Integrated I-V Test System is designed to overcome the limitations of flash testing by providing a highly optimized pulse width and voltage sweep rate to match any type of solar cell’s high capacitance and slow dielectric response speed. As a result, the system produces extremely accurate measurements of solar cell I-V parameters and efficiency while leading to the most accurate test results.

  • Power Transformer Automatic Test Device

    XD71 - Hangzhou Xihu Electronic Institute

    The device is used for power transformer power outage routine test items to do automated testing.Which is characterized by dielectric loss, insulation resistance, DC resistance, tap-changer switching characteristics, short circuit impedance and variable ratio of six test items are concentrated in an instrument,so that the instrument function, test power and test lead height fusion.Field test, just start wiring once, at the end of unplugging wiring once,the middle process by the test personnel in the computer terminal to send command control,the test system automatically completes all or part of the above test items.

  • Multifunctional Safety Tests

    LXinstruments GmbH

    Manufacturers of electrical or electronic products are required by law to carry out an electrical safety test before placing them on the market. This final test takes place at the end of the manufacturing process and is therefore also referred to as an EOL test (end-of-line). Depending on the prescribed standard and directive, the following parameters are tested:- Leakage current and discharge current- Insulation resistance or the insulation strenth- Dielectric strength or electric strength- Correct installation of the protective conductor (ground continuity and ground bond test)- Faultless functioning of the product under the conditions defined for intended use (function or run test

  • Petroleum Testing Solutions

    Labodam

    Acid andalkali testers, aniline test equipment, automatic bomb calorimeters, automatic dielectric tester, closed cup flash point tester, demulsibility characteristics tester, density tester, distillation tester, dropping point tester, engler viscometer, existent gum tester, kinematics viscometer, low temperature tester, octant number and cetane number tester, open cup flash point tester, oxidation stability tester, oxygen bomb calorimeter, penetrometer, residue carbon, rotational viscometer, rust and corrosion tester, specific gravity tester, sulphur content tester, vapor pressure, water content tester.

  • RFID Chamber

    Cuming-Lehman Chambers

    – 80dB RF shielded enclosure (inside dim.- 5’ high x 5’ wide x 7’ long)– Fabrication, Construction, and Transportation– Free standing shielded enclosure design including structural support system– Enclosure will be installed over a continuous 1/8″ dielectric underlay and polyethylene vapor barrier– Modular wood-core panel construction– Bulkhead connector panel – (1) 12” x 12”– RF shielded doors – (2) 2’ x 2’– One (1) Antenna Sinclair Model SP-440-SF2SNF– Shield test per IEEE –STD 299- supersedes MIL-STD-285 (Tested @ 1 GHz)– RAM

  • Fluid Property Sensors

    TE Connectivity Ltd.

    TE Connectivity (TE) offers distinct fluid property sensor technologies to measure fluids. Our tuning fork technology is coupled with efficient software algorithms for accurate measurement of viscosity, density, and dielectric constant. Dedicated applications for our DEF sensors include oils quality sensors (engine, hydraulic, transmission), fluid monitoring, and others. Our urea quality SCR sensors, based on Ultrasonic Technology (UST), perform an analysis of the Diesel Exhaust Fluid (DEF) fluid to provide urea concentration and secure mis-filling protection to the Selective Catalytic Reduction systems. Our highly reliable reed switch technology is combined with temperature measurement for DEF level sensing.

  • MMW Field Sensors

    ITS-9050 - Innovative Technical Systems

    The Innovative Technical Systems ITS-9050 Detector is a sensitive, harmonic mixing detector designed to measure millimeter-wave free-space radiation. It is ideal for measuring radiation patterns of antennas inboth the near and far-field. The ITS-9050 employs a free-running dielectric resonator oscillator (DRO) and an integrated harmonic mixer with a waveguide RF input that either connects directly to a circuit under test or to an antenna for radiation detection. The resulting IF is amplified and detected by an IF log-detector that drives a front panel LCD voltmeter to provide an indication of signal strength. A DC output voltage from the log detector is available on a BNC connector to drive external data acquisition instrumentation. Also, a sample of the IF output is provided for measurement on a spectrum analyzer.

  • Portable Digital Manometer

    PS309 - Validyne Engineering

    Featured are an integral variable reluctance transducer, solid state electronics module, 3 digit liquid crystal display (LCD)* and battery pack with six 1.5V penlight cells for truly portable operation. The units can also be powered from an external DC power supply or AC battery eliminator (converter) module. The transducer features all corrosion resistant materials in contact with the pressure media (both ports in differential units), very low internal cavity volumes and ultra-low volumetric displacement with full-scale pressure excursion. Transducer calibration is unaffected by dielectric properties of the sensed fluid. Gauge and differential transducers may be disassembled and range changed by simple diaphragm replacement.

  • H.V. Insulation Testers (OLED Display 1kV up)

    6213A IN-M - Standard Electric Works Co., Ltd

    ● High contrast OLED display● Designed for viewing in the dark, for mining industry.● Wide viewing angle.● Smart microprocessor-controlled.● 2 x 16 characters, large, High Contrast, Intelligent OLED Display.● Automatically calculates Dielectric Absorption Ratio (DAR).● Automatically calculates Polarization Index (PI).● Insulation resistance; Auto-ranging on all ranges.● Ener-Save● Bar graph indicates test voltage. Rise and decay can be obeserved.● External voltage presence warning (>500Vac or Vdc)● Overload protection● Low battery indicator (real time battery voltage mearsurement)● Measures insulation time duration of the test● Better than 10% accuracy on all ranges● Auto-off

  • Digital 10kV High Voltage Insulation Tester

    4310 IN - Standard Electric Works Co., Ltd

    • Protection class: IP65 (Lid closed)• 2 Lines × 16 Characters LCD• Microprocessor-controlled• Tests insulation resistance up to 2 TΩ • 4 Insulation test voltages: 1000V, 2500V, 5000V, 10000V• AC / DC Voltmeter (30~600V)• Short-circuit current up to 5mA• PI (Polarization Index) indication• DAR (Dielectric Absorption Ratio) indication• Auto-ranging on all insulation ranges• Auto-hold function to freeze reading• Overload protection• Adjustable testing duration: 1~30 minutes• Internal memory for data storage• Displays testing duration for insulation measurement • Auto-off function• 200 measurement results can be saved in memory and recalled on display

  • Digital 5kV High Voltage Insulation Tester

    4305 IN - Standard Electric Works Co., Ltd

    • Protection class: IP65 (Lid closed)• 2 Lines × 16 Characters LCD• Microprocessor-controlled• Tests insulation resistance up to 1 TΩ • 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V• AC / DC Voltmeter (30~600V)• Short-circuit current up to 5mA• PI (Polarization Index) indication• DAR (Dielectric Absorption Ratio) indication• Auto-ranging on all insulation ranges• Auto-hold function to freeze reading• Overload protection• Adjustable testing duration: 1~30 minutes• Internal memory for data storage• Displays testing duration for insulation measurement • Auto-off function• 200 measurement results can be saved in memory and recalled on display

  • Lens Antennas

    ERAVANT

    A lens antenna is a directional antenna that uses a shaped piece of microwave-transparent material to bend and focus microwaves by refraction, as an optical lens does for light.[1] Typically it consists of a small feed antenna such as a patch antenna or horn antenna which radiates radio waves, with a piece of dielectric or composite material in front which functions as a converging lens to collimate the radio waves into a beam.[2] Conversely, in a receiving antenna the lens focuses the incoming radio waves onto the feed antenna, which converts them to electric currents which are delivered to a radio receiver. They can also be fed by an array of feed antennas, called a focal plane array (FPA), to create more complicated radiation patterns.

  • High Voltage Surge Testers

    HVST - Test Electronics

    The most important features of the surge tester are its ability to test the entire winding insulation system. A high voltage surge generates turn to turn, coil to coil, and phase to phase voltage stress, as well as ground insulation stress. When used as a dielectric test, accurate voltage readings are essential. The HV Surge Tester monitors the voltage directly across the winding under test. This voltage is displayed on an oscilloscope and recorded on the Pass/ Fail LED latch monitor. This voltage will be accurate despite the impedance of the winding being tested. The insulation system can be tested way above the operating voltage because of the brief duration of the applied voltage test pulse. This allows faults to be detected long before they become apparent at operating conditions.

  • Semi-Rigid Test Probes Up to 6 GHz

    Fairview Microwave Inc.

    Fairview Microwave’s semi-rigid test probe assemblies come in multiple cable diameters to help when attaching the unterminated end of the probe to a circuit board trace. There are two versions including straight-cut probe ends for those that would like to customize the dimensions of the center conductor and dielectric dimensions, as well as pre-stripped probe ends that are ready for immediate use. By soldering the outer conductor to the signal ground and the exposed center conductor to the trace carrying the signal of interest, simple sampling measurements can be made without having to create a separate subassembly circuit board or add a connector to the circuit layout which can take up valuable real estate. Fairview provides 3 diameters of semi-rigid coax and 3 different lengths from 3 inches to 12 inches to fit a variety of trace widths and applications. All test probes are 100% RF tested to ensure the cable assemblies operate to 6 GHz and also to make sure that the SMA connector interface meets the 1.35:1 VSWR specification prior to shipping. To protect the small diameter coax from damage, each part is shipped in a clear protective tube that can also be used for storing the probes for future use.

Get Help