Showing results: 1051 - 1065 of 3690 items found.
-
E36155ABV -
Keysight Technologies
Better value bundle of E36155A DC power supply, single-output, auto-range: 60V, 40A, 800W: LAN, USB, E36150ADVU, and BV9200B BenchVue Advanced Power Control Analysis – Four Instruments Connection.
-
E36154ABV -
Keysight Technologies
Better value bundle of E36154A DC power supply, single-output, auto-range: 30V, 80A, 800W: LAN, USB, E36150ADVU, and BV9200B BenchVue Advanced Power Control Analysis – Four Instruments Connection.
-
HMMC-3028 -
Keysight Technologies
The HMMC-3028 is a DC - 12 GHz divide by eight prescaler designed for use in high frequency communications, microwave instrumentation, and EW radar systems where low phase-noise PLL control circuitry or broadband frequency translation is required.
-
HMMC-3022 -
Keysight Technologies
The HMMC-3022 is a DC - 12 GHz divide by two prescaler designed for use in high frequency communications, microwave instrumentation, and EW radar systems where low phase-noise PLL control circuitry or broadband frequency translation is required.
-
HMMC-3024 -
Keysight Technologies
The HMMC-3024 is a DC - 12 GHz divide by four pre scaler designed for use in high frequency communications, microwave instrumentation, and EW radar systems where low phase-noise PLL control circuitry or broadband frequency translation is required.
-
N6952A -
Keysight Technologies
When designing high performance ATE systems, there's an art to the tradeoffs you make when asked to "integrate fast and test faster within budget." That's why Keysight's N6900 Series DC power supplies are small, flexible and market-leading fast. And with our VersaPower architecture, you can tune the N6900 for the optimum balance of test coverage, quality and time.
-
N6951A -
Keysight Technologies
When designing high performance ATE systems, there's an art to the tradeoffs you make when asked to "integrate fast and test faster within budget." That's why Keysight's N6900 Series DC power supplies are small, flexible and market-leading fast. And with our VersaPower architecture, you can tune the N6900 for the optimum balance of test coverage, quality and time.
-
N6953A -
Keysight Technologies
When designing high performance ATE systems, there`s an art to the tradeoffs you make when asked to "integrate fast and test faster within budget." That's why Keysight's N6900 Series DC power supplies are small, flexible and market-leading fast. And with our VersaPower architecture, you can tune the N6900 for the optimum balance of test coverage, quality and time.
-
N6950A -
Keysight Technologies
When designing high performance ATE systems, there's an art to the tradeoffs you make when asked to "integrate fast and test faster within budget." That's why Keysight`s N6900 Series DC power supplies are small, flexible and market-leading fast. And with our VersaPower architecture, you can tune the N6900 for the optimum balance of test coverage, quality and time.
-
E36155AGVX -
Keysight Technologies
The Keysight E36155AGVX consists of a Keysight E36155A DC power supply, a Keysight E36150ADVU Scope View and arbitrary waveform generation (AWG) capabilities, and a Keysight E36150ATMU Automotive Standards Testing Capabilities with Enhanced Programming Speed, ISO Preset Library, Playback Simulation and E-Logging features. The E36155A includes single-output and auto-range capabilities, 60V, 40 A, 800 W, and LAN and USB interfaces.
-
E36154AGVX -
Keysight Technologies
The Keysight E36154AGVX consists of a Keysight E36154A DC power supply, a Keysight E36150ADVU Scope View and arbitrary waveform generation (AWG) capabilities, and a Keysight E36150ATMU Automotive Standards Testing Capabilities with Enhanced Programming Speed, ISO Preset Library, Playback Simulation and E-Logging features. The E36154A includes single-output and auto-range capabilities, 30V, 80 A, 800 W, and LAN and USB interfaces.
-
779647-31 -
NI
±20 V, ±2 A DC, 40 W PXI Source Measure Unit - The PXI‑4130 is a programmable source measure unit (SMU). It has a single isolated SMU channel that offers a four-quadrant output that incorporates remote (4‑wire) sense. With its five current ranges, it is ideal for transistor characterization that requires accurately sourcing a constant current or voltage while sweeping another current. The PXI‑4130 also includes a utility channel that can source either current or voltage. This PXI SMU can act as either a constant voltage source or a constant current source, with a settable compliance limit for either mode. In addition, you can enable remote sense on the SMU channel to maximize voltage output and measurement accuracy on your device under test (DUT) for high-precision applications.
-
Aplab Limited
- 300W to 1280W different combination- High current density.- 19″ rack adaptable -3U high- Remote sensing.- Front panel potentiometer to set V&I- 3Digit seven segment display for V&I- High stability and close regulation- Phase controlled preregulation plus linear post regulation- Optional, at extra cost- Over voltage protection- 19″ rack mounting- Analogue programming and monitoring for V&I
-
LAB Series -
Aplab Limited
- 19” Rack Adaptable- Constant Voltage / Constant Current Operation- Two Digital Meters – 3 Digit DPMs- Phase Controlled PreRegulation Plus Linear PostRegulation- Remote Sensing Facility- High Stability and Close Regulation ±0.01%OPTIONS AT EXTRA COSTa) Presetting Facilityb) Over Voltage Protectionc) 19” Rack Mountingd) Analog programming &monitoring for Voltage &Current.
-
CK562A -
Spanawave Corporation
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.