Filter Results By:

Products

Applications

Manufacturers

DC

Direct Current

See Also: Direct Current


Showing results: 2641 - 2655 of 3692 items found.

  • Regenerative Power System, 2000 V, ±30 A, 20 KW, 400/480 VAC

    RP7973A - Keysight Technologies

    The RP7973A regenerative power system is a single output, bi-directional, regenerative DC power supply with highly integrated safety features that protect both your people and your device under test.

  • HV Probes & Multimeters

    B-1010, B1010-A, B-1012, B-1012-A - ROSS ENGINEERING CORPORATION

    HV Probes and Voltmeters for oscilloscopes, DVMs, recorders. HV DC, AC & Wideband DC-10MHz. Safety probes for any scope, digital display or recorder. Also available complete with large 4½ digit display 0.01% to 5% DC/AC accuracy digital voltmeter, with safety handles for OSHA recommended personnel clearances. With attached or separate digital display or multimeter 0.00001V to 400kV. HV Digital Multimeters. Wideband DC-10MHz. VMD2A 4½ digit portable meter has accuracies to 0.01% DC, 0.1% 50/60Hz, 3% DC-1MHz, 3dB to 10MHz. True RMS, Avg, True +PK, -PK, PK to PK, 0.2 microsecond, 1/2 sine single pulse capture & hold. 0.00001V - 1000V DC or PK AC and for use with HV Probes to 400kV and Voltage Dividers to 1,000,000V. Has 2V output to scope, recorder. To 1000kV with HV divider, DC-10MHz.

  • Transmission Line Probes

    Teledyne LeCroy

    Transmission line probes are a special type of passive probe designed for use at very high frequencies. They replace the high impedance probe cable found in a traditional passive probe with a precision transmission line, with a characteristic impedance that matches the oscilloscope input (50 Ohm). This greatly reduces the input capacitance to a fraction of a picofarad, minimizing the loading of high frequency signals. A matching network at the tip increases the DC input resistance. While they have lower DC input resistance than a traditional passive probe (usually 500 Ohm) to 1kOhm), the input impedance of these probes remains nearly constant over their entire frequency range. A traditional /10 passive probe will have a 10 MOhm) input impedance at DC, however this impedance drops rapidly with frequency, passing below the input impedance of a transmission line probe at less than 100 MHz.

  • Fully Automatic Transformer Winding Resistance Tester

    Neutronics Manufacturing Co.

    Measure DC resistance of transformers windings etc. Introduction: The NMC ''TDR'' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. ''TDR'' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. ''TDR'' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.Principle: The constant current generated is fed to the resistance under test through the current terminals and the voltage drop across the resistance under test is measured and displayed in ohms. A true four terminal measurement is used to eliminate the need for lead resistance compensation.

  • True RMS Digital Multimeter

    MM68 - Martindale Electric Co. Ltd

    The MM68 is a True RMS digital multimeter which measures AC voltage up to 750V, DC voltage up to 1000V and both AC and DC current up to 10A.

    It measures frequency, capacitance, resistance, and also has duty cycle, diode test and an audible continuity test which sounds at less than 100Ω. The 4½ digit LCD screen displays the results as values and on a 22 segment analogue bar graph. The MM68 also has an auto-power off feature and on screen low battery indication.

  • AC/DC TRMS Insulation Clamp Meter

    CMi210 - Martindale Electric Co. Ltd

    A unique insulation clamp meter for the installation, testing and maintenance of domestic and industrial installations. This high specification clamp meter can perform insulation tests to 6G Ohms with 5 test voltages from 50V to 1000V.

    The clamp provides True RMS measurement of AC current to 1500A and AC voltage to 750V. It will also measure DC current to 2000A and DC voltage to 1000V. The CMi210 has all the same test functions you would expect to find on a high specification multimeter with the added benefit of temperature measurement.

  • 200 A Safety Ground Tester With Built-In Thermal Printer

    SGT-200 - Manta Test Systems

    The Vanguard SGT-200 Safety Ground Tester is a 200A DC micro-ohmmeter designed specifically to measure the resistance of protective in-service grounding and jumper cable assemblies. The SGT-200 can measure the resistance of the grounding cables, clamps and ferrules. The measured resistance values can be compared against the calculated values (using the ASTM 2249-03 standard) and a Pass/Fail result can be printed along with the measured resistance values. Since the SGT-200 uses a DC current, there is no need to uncoil the cable under test. It can be conveniently tested in its coiled state in a much smaller testing enviornment.

  • Digital (1kV below) Insulation Tester

    2151 IN - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● 68 × 34mm(2.677” × 1.338”) large LCD display.● 3½ digital LCD(2000 counts) a LCD indicated instrument for insulation.(MΩ), continuity(Ω) and AC voltage.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA DC load.● >200mA short circuit testing current for a resistance tests.● Auto ranging.● REL function.● Auto power OFF.● Fuse protection.● Auto data hold.● BS 16 edition.

  • Load Cell Amplifier Signal Conditioner with DB9 Connectors

    MODEL LCA-9PC - Transducer Techniques, Inc

    The LCA-9PC Module provides low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-9PC comes with DB9 male and female connectors, which require soldering to user-furnished mating female or male wire connectors. On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film otentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.

  • Load Cell Amplifier Signal Conditioner with Removeable Terminals

    MODEL LCA-RTC - Transducer Techniques, Inc

    The LCA-RTC Module provide low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-RTC comes with removable screw-clamp terminal connectors, which accept wires without soldering.On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film potentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.

  • Analog Tensile Testing Machine

    Atico Export

    It can test materials like rubber, wood, plastic, rexins, teflon, cardboard, composites, ferrous metals, non-ferrous metals etc.Wide range of Grips, Attachments & Special fixtures are available to suit varieties of material and shapes. Continuous roll autographic Load Vs Elongation recorder.Continuous roll autographic Load Vs Elongation recorder.Elongation scale with least count 1 mm.Elongation scale with least count 1 mm.Three measuring ranges for accurate testing.Three measuring ranges for accurate testing.A number of straining speeds are available for proper selection.A number of straining speeds are available for proper selection. Machine with AC or DC drive motor is available.Machine with AC or DC drive motor is available.Various Models – Maximum Capacity from 200 N to 50 kN.Various Models – Maximum Capacity from 200 N to 50 kN.Loading accuracy well within ±1%Loading accuracy well within ±1%Hand operated cutting press with different sizes dies are available for cutting dumbbell specimen.Hand operated cutting press with different sizes dies are available for cutting dumbbell specimen.

  • Current And Voltage Transformer Test Set

    iCT1 - Altanova Group

    iCT1 - CT/VT Test Set is the NEW and most advanced portable equipment capable to test current, voltage and combined transformers.With the low voltage method, known as "DC method", iCT1 is able to test Current Transformers with a very high saturation voltage, up to 30 kV, in a complete safety mode. Quick and easy to use tool, iCT1 allows to perform tests in one shot without changing the connection to the CT, thanks to the integrated 5-TAP Switchbox.

  • Current Sense Amplifiers

    Analog Devices Inc.

    Analog Devices’ current sense amplifiers offer excellent performance for a wide array of automotive and power management applications. These devices accurately amplify small voltages in the presence of large common-mode voltage, and provide high bandwidth, as well as level shifting and bidirectional capability. Excellent dc and ac accuracy over a wide temperature range from –40°C to +125°C minimizes errors in your measurement loop while not sacrificing on cost and package size.

  • Digital Clampmeters

    Meco Instruments Pvt. Ltd.,

    AC Current 40A, 400A, 1000A AC Voltage 4V, 40V, 400V, 750V (Auto) (40-500Hz) DC Voltage 4V, 40V, 400V, 1000V (Auto) Resistance 400Ω, 4KΩ, 40KΩ, 400KΩ, 4MΩ, 40MΩ (Auto) Frequency 10.00 Hz, 50.00 Hz, 500.0 Hz, 5.000 KHz, 50.00KHz, 500.0 KHz(Auto) Sp. Functions Data Hold, Audible Continuity, Diode Test, APO Jaw Opening 43mm Max.

  • Dual Display Auto-Ranging LCR Meter

    LCR 459 - Kusam Electrical Industries Limited

    • Dual Displays provide quick tested results readouts, with L.C.R. display values up to 19999 counts and Q.D.R. display values up to 9999 counts • Test 4 parameters : Ls+(Q,D,Rs), Lp+(Q,D,Rp), • Cs+(Q,D,Rs), Cp+(Q,D,Rp) • RS-232 PC Interface • External DC Adapter functions • Set Hi / Lo limits using absolute values or percentage limits.

Get Help