  • Ground-Fault Location Products for Ungrounded Systems

    Bender Inc.

    When combined with Bender's ground-fault detectors and current transformers, EDS series modules provide fast, automatic ground-fault location in ungrounded systems. Fault location takes place while the system remains online without the need to open branch circuit breakers or disconnect equipment. Bender's fault location system works on both AC and DC systems, as well as systems with variable frequency drives. A standalone, portable fault location system is also available.

  • MCB Thermal Trip Calibration Test Bench (IEC 60898 Cl 9.10.1.2, Annex I.1, IS)

    SCR ELEKTRONIKS

    The test system is designed and customized to carry out 2.55*Intest as per Table 7 (test c) of IEC 60898 (also mentioned for routine testing of MCBs. The test is done at dc current to exactly analyze and correct the bimetallic properties of the MCB as far as thermal tripping is concerned. The unit comes with a pneumatically operated test fixture with in-built dc stepper motor that is controlled by a micro controller / PC to calibrate the breaker into a narrow tripping band programmed by the user.

  • Real-Time Open Check Hi-Pot Tester

    DU3328 - Delta United Instrument Co., Ltd.

    Programmable test voltage in AC: 0.1K~5KV, DC: 0.1K~6KV Programmable cutting current in AC:0.001mA~15mA, DC: 0.001mA~7.5mA 3 in 1 functions, with AC, DC Hi-Pot test, Insulation test. Built in 100 sets memory Arcing detect function 8 ports scanning function Independent 8 channels real-time open check Real-time check function, to ensure your products tested, no more loss test.

  • Voltage Testers

    Morris Products Inc.

    Electrical Receptacle Tester Instantly Displays Wiring Condition of Any Standard 3-Wire AC 110-120 OutletNeon Indicators Give Positive Indication of Current StatusCompact Unit Simply Plugs into any Standard 3 Wire/Grounded Receptacle (110–125 Volt AC Circuits)Tests for 6 Circuit Conditions: Open Ground, Open Neutral, Open Hot, Hot/Ground Reverse, Hot/Neutral Reverse & Correct WiringBlister PackedcULus ListedOrder Qty of 1 = 1 Piece

  • Aging and Optical Attenuation Tester

    LS822 - Lisun Electronics Inc.

    • Build-in DC Power Supply: Forward current preset: 0.1-800mA (special order) Range of forward voltage: 0.1-20.00V • Range of luminous intensity: 1mcd-3,000cd • Range of luminous flux: 1mlm-9,999,000lm(depends on the size of sphere) • Accuracy of photometer: class1; accuracy of electricity: class0.5 • Aging time: 9999Hours 59Munites 59Seconds • Tolerance of time: ±1S/10H • Record time: 16000times • Hold data automatically when the power is off and continue to work automatically when the power is turned on.

  • PXI-2586, 10-Channel, 12 A, SPST PXI Relay Module

    778572-86 - NI

    10-Channel, 12 A, SPST PXI Relay Module—The PXI‑2586 is a general-purpose switch module that features independent single‑pole single‑throw (SPST) Form A armature relays. Each relay has low contact resistance and high isolation voltage. The PXI‑2586 is fully software programmable. It is rated for both high currents and high voltages, so it is ideal for switching power signals and loads in control applications and battery, power supply, and automotive testing.

  • Transformer Testing

    Technology Products

    The ART-3D series of Automatic Ratio Testers are precision instruments, designed to measure the turn ratios, phase displacements, excitation currents of single phase and three phase power, distribution and instrument transformers in conformity to the IEEE C57.12.90 & IEC 60076. Now featuring an enhanced test lead design, the ART-3D is the perfect instrument for real-life field usage. ART-3D series also has Anti Induction circuit which makes it suitable for system voltages upto 765KV.

  • 5A Microohm Meter

    9005 UO - Standard Electric Works Co., Ltd

    ● Maximum testing current of 5A ● Ranges:    2000μΩ / 20.00mΩ             5A   20.00mΩ / 200.0mΩ           1A     2.000Ω / 20.00Ω          100mA    200.0Ω                              10mA● Maximum resolution of 1μΩ at 5A● Four terminal measurement● 4 Lines × 20 Characters LCD ● Memery function (200 measurement results)● Auto power off● Low battery indication● Power source: 1.5V "C" alkaline battery × 8● Safety Standard:   EN 61010-1 CAT III 300V   EN 61326-1

  • Insulation & Multifunction Tester (LCD Display)

    4101 IN - Standard Electric Works Co., Ltd

    ● Measures Insulation Resistance, voltage (AC-DC) measurements.● Automatic hold facility.● Continuity test with a short circuit current of minimum 200mA.● Energy conservation is feature.● EnerSave™ limits the test duration to about 10 Seconds to save energy.● No moving parts. All calibration are saved internally in a non volatile memory.● Easy calibration at any facility around the world.● Low cost maintenance, calibration, and ownership.● Complies to all the latest regulations, including UK.

  • Low Resistance Ohmmeters

    Megger Group Ltd.

    Some times know as Ducter testers, these are highly accurate, easy to operate instruments that measure resistance with resolution as fine as 0.1 micro-ohm. Digital micro-ohmeters and DLROs measure contact resistance of switch and circuit breakers, aircraft frame bonds, and rail and pipeline bonds just to name a few of the applications. Megger has models available for testing using test currents from 0.5 mA to 200 amps covering a multitude of applications that require precise low-resistance measurements.

  • PXI 2A Multiplexer, 2-Bank, 64-Channel 1-Pole

    40-614-010 - Pickering Interfaces Ltd.

    The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.

  • Transformer Test Equipment

    IBEKO Power AB

    DV Power test instruments perform various diagnostic tests on power and instrument transformers. Even more, a unique feature is a condition assessment of on-load tap changers. Performing a transformer test before their breakage can be crucial.Test instruments are portable and enclosed in durable metal cases. Also, the 19” rack-mounted version suitable for factories is available as well.Applications supported by DV Power transformer test equipment include:Winding resistance measurement (IEC 60076-1)Analysis of on-load tap changers (IEC 60214-1)Heat run test (IEC 60076-2)Automatic transformer demagnetizationTurns ratio measurement of power and instrument transformers (IEC 60076-1)Excitation current measurementPhase angle measurementTransformer vector group detectionDemagnetization status verificationAll of the above-mentioned measurements are performed with the highest accuracy.The advanced DV-Win PC software collects both numerical and graphical results. As a result of that, these features provide an easier and more efficient analysis. After the test, DV-Win software generates a test report with a single click. Furthermore, a user can easily customize the test report and save it in different formats, such as XLS or PDF.Finally, the analysis of on-load tap changers is performed by the new method called dynamic resistance measurement (DRM). This is a non-intrusive method. Therefore, it allows detecting problems in on-load tap changers without disassembling them.

  • Analog Clamp Meter

    DER EE Electrical Instrument

    Operation0C~ 40C(32~104)/<80% R.H.(no condensation) Storage-10C~ 50C(14~122)/<70%R.H.(no condensation) Dimension & Weight 243(L)x91(W)x45(H)mm Approx.360g (Including battery) Accessories Battery UM-3 (AA) 1.5V x1 Instruction Manual x1 Test Lead (red + black) x 1 Carrying case x1 Optional Accessories Temp. Probe (NR-81) AC Line Splitter(DE-10ALS) *Applicable to electrical appliances small current

  • True RMS Digital Multimeter

    MM94 - Martindale Electric Co. Ltd

    The MM94 is a high performance True RMS multimeter with a 600V CAT IV safety rating.

    It has an extended current measurement range up to 20A for short cycle measurements. Measurement capabilities include AC/DC voltage, capacitance, resistance and temperature with the included K Type thermocouple. Features include Min/Max and Peak measurement and a high frequency filter to optimise readings for distorted waveforms plus a relative mode.

    The rugged design includes a 60,000 count backlit display with analogue bargraph.

  • Multi Output Regulated DC Power Supply

    LQ6324T - Aplab Limited

    - Low cost general purpose laboratory bench unit.- Fully protected against overload and short circuit.- Three independent outputs electrically isolated from each other.- 5V/5A with over voltage crowbar protection for digital ICs.- Electrically floating outputs up to 500V DC w.r.t. ground.- Compact modular construction.- Precise regulation, low ripple and noise for both constant voltage and constant current operation.- Quality components and conservating ratings for high reliability and long life.