Filter Results By:

Products

Applications

Manufacturers

Showing results: 4561 - 4575 of 5185 items found.

  • FC Impedance Meters

    Kikusui Electronics Corp.

    designed for testing of the fuel cell with the small current (5 A or less), and not only the current-voltage characteristic test, the KFM2005 can easily measure for the impedance of a fuel cell using the AC impedance method, and the Cole-Cole plot. Using the measurement data of the Cole-cole plot, it is possible to calculate the circuit constant of the approximate equivalent circuit of the fuel cell. The built-in DC load (60W) is capable to operate from 0 V, and it can perform the test for the fuel cell up to 20V and 5A.

  • DC Power Supplies

    XG 850 - AMETEK Programmable Power, Inc.

    The Sorensen XG Series is an 850 Watt, 1U half-rack DC power supply. The XG Series is the new standard for powerful, programmable DC power systems. Designed for test, production, laboratory, OEM and quality assurance applications, the XG Series provides a wealth of features to ensure accuracy and greater efficiency. It puts clean, reliable power at your disposal and delivers stable, variable output voltage and current for a broad range of development, test and system requirements.

  • Ground Earth Resistance Tester

    2678X - Shenzhen Chuangxin Instruments Co., Ltd.

    Ground Earth Resistance Tester verifies the integrity (continuity) of the protective bonding of the equipment (Class I equipment) designed to secure safety through the basic insulation and protective earthing. It is also called earth (ground) bonding test. If the continuity of the protective bonding is confirmed, we can conclude that the equipment has the requirements for preventing electric shock even if the insulation between the primary circuit and the accessible conductive section fails and a fault current flows through the distribution system.

  • 6U Form Factor PMC/PrPMC Carrier-VMEbus

    i4400 - AcQ Inducom

    The i4400 is a low-cost 6U form factor PMC / PrPMC carrier for the VMEbus and forms the basis of a flexible I/O system. It offers the user a means of integrating two single PMC modules or one double PMC module in a VMEbus system. The current version of the i4400 supports PMC modules and also supports Processor PMC modules on one PMC-site. The VME-to-PCI bridge is implemented in an FPGA for flexible VME-to-PCI mapping and to allow future updates and upgrades.

  • Bench top Dielectric Withstand tester

    HYPOT III - Wavecontrol, S.L.

    RS-232 Interface available for automated controlPatented SmartGFI® functionPatented CAL-ALERT® functionComes complete with a test box for products terminated in a line cordPatented VERI-CHEK® functionStorage of up to 10 setups with 3 steps per setupBuilt-in security settingsDigitally controlled arc detection systemNo load setup of trip current and output voltageElectronic ramping (up & down)Built-in adjustable continuity testInterconnection to HYAMP® III to form complete test system

  • SCR Rectifiers

    Carl E. Holmes Company

    SCR-controlled rectifiers are electronically controlled via analog signals for constant voltage and current control. The compact and service-friendly design complies with high industrial requirements and guarantees excellent operational reliability.The input voltage can be from 208 VAC to 600 VAC, 3 PH, 50/60 Hz. Maximum output voltage can be from 6 VDC to 600 VDC. Maximum output can be from 1000 Amps to 100000 Amps. These units can be air cooled, water cooled or oil cooled.

  • Ground-Fault Location Products for Ungrounded Systems

    Bender Inc.

    When combined with Bender's ground-fault detectors and current transformers, EDS series modules provide fast, automatic ground-fault location in ungrounded systems. Fault location takes place while the system remains online without the need to open branch circuit breakers or disconnect equipment. Bender's fault location system works on both AC and DC systems, as well as systems with variable frequency drives. A standalone, portable fault location system is also available.

  • MCB Thermal Trip Calibration Test Bench (IEC 60898 Cl 9.10.1.2, Annex I.1, IS)

    SCR ELEKTRONIKS

    The test system is designed and customized to carry out 2.55*Intest as per Table 7 (test c) of IEC 60898 (also mentioned for routine testing of MCBs. The test is done at dc current to exactly analyze and correct the bimetallic properties of the MCB as far as thermal tripping is concerned. The unit comes with a pneumatically operated test fixture with in-built dc stepper motor that is controlled by a micro controller / PC to calibrate the breaker into a narrow tripping band programmed by the user.

  • Real-Time Open Check Hi-Pot Tester

    DU3328 - Delta United Instrument Co., Ltd.

    Programmable test voltage in AC: 0.1K~5KV, DC: 0.1K~6KV Programmable cutting current in AC:0.001mA~15mA, DC: 0.001mA~7.5mA 3 in 1 functions, with AC, DC Hi-Pot test, Insulation test. Built in 100 sets memory Arcing detect function 8 ports scanning function Independent 8 channels real-time open check Real-time check function, to ensure your products tested, no more loss test.

  • Voltage Testers

    Morris Products Inc.

    Electrical Receptacle Tester Instantly Displays Wiring Condition of Any Standard 3-Wire AC 110-120 OutletNeon Indicators Give Positive Indication of Current StatusCompact Unit Simply Plugs into any Standard 3 Wire/Grounded Receptacle (110–125 Volt AC Circuits)Tests for 6 Circuit Conditions: Open Ground, Open Neutral, Open Hot, Hot/Ground Reverse, Hot/Neutral Reverse & Correct WiringBlister PackedcULus ListedOrder Qty of 1 = 1 Piece

  • Aging and Optical Attenuation Tester

    LS822 - Lisun Electronics Inc.

    • Build-in DC Power Supply: Forward current preset: 0.1-800mA (special order) Range of forward voltage: 0.1-20.00V • Range of luminous intensity: 1mcd-3,000cd • Range of luminous flux: 1mlm-9,999,000lm(depends on the size of sphere) • Accuracy of photometer: class1; accuracy of electricity: class0.5 • Aging time: 9999Hours 59Munites 59Seconds • Tolerance of time: ±1S/10H • Record time: 16000times • Hold data automatically when the power is off and continue to work automatically when the power is turned on.

  • PXI-2586, 10-Channel, 12 A, SPST PXI Relay Module

    778572-86 - NI

    10-Channel, 12 A, SPST PXI Relay Module—The PXI‑2586 is a general-purpose switch module that features independent single‑pole single‑throw (SPST) Form A armature relays. Each relay has low contact resistance and high isolation voltage. The PXI‑2586 is fully software programmable. It is rated for both high currents and high voltages, so it is ideal for switching power signals and loads in control applications and battery, power supply, and automotive testing.

  • Low Resistance Ohmmeters

    Megger Group Ltd.

    Some times know as Ducter testers, these are highly accurate, easy to operate instruments that measure resistance with resolution as fine as 0.1 micro-ohm. Digital micro-ohmeters and DLROs measure contact resistance of switch and circuit breakers, aircraft frame bonds, and rail and pipeline bonds just to name a few of the applications. Megger has models available for testing using test currents from 0.5 mA to 200 amps covering a multitude of applications that require precise low-resistance measurements.

  • 5A Microohm Meter

    9005 UO - Standard Electric Works Co., Ltd

    ● Maximum testing current of 5A ● Ranges:    2000μΩ / 20.00mΩ             5A   20.00mΩ / 200.0mΩ           1A     2.000Ω / 20.00Ω          100mA    200.0Ω                              10mA● Maximum resolution of 1μΩ at 5A● Four terminal measurement● 4 Lines × 20 Characters LCD ● Memery function (200 measurement results)● Auto power off● Low battery indication● Power source: 1.5V "C" alkaline battery × 8● Safety Standard:   EN 61010-1 CAT III 300V   EN 61326-1

  • Insulation & Multifunction Tester (LCD Display)

    4101 IN - Standard Electric Works Co., Ltd

    ● Measures Insulation Resistance, voltage (AC-DC) measurements.● Automatic hold facility.● Continuity test with a short circuit current of minimum 200mA.● Energy conservation is feature.● EnerSave™ limits the test duration to about 10 Seconds to save energy.● No moving parts. All calibration are saved internally in a non volatile memory.● Easy calibration at any facility around the world.● Low cost maintenance, calibration, and ownership.● Complies to all the latest regulations, including UK.

Get Help