Filter Results By:

Products

Applications

Manufacturers

Showing results: 4051 - 4065 of 5366 items found.

  • 300W Electronic Load

    EL3630B - MCH Instruments Co.,Ltd.

    Features:*Number operation and control*LED display with high definition and high contrast, rich display information*Easy operation of knob encoder switch*Basic load function: constant current, voltage, power and resistance*Multi units used to multiple load ability*Short-circuit test*Battery test*Dynamic test*Multi parameters measured in the list*Remote voltage measurement*Panel and exterior trigger function*Protection function: over-voltage, over-current, over-power, over-heat, polarity connection in reverse*10 sets of parameters memorized and loaded, and automatically loaded on turning on the instrument*Intelligent fan control*Key lock and knob lock functions

  • AC Clamp Meters

    CHY firemate Co., Ltd.

    Power measure of Active power (KW), Reactive power (KVAR),Apparent power (KVA), Power Factor (PF)PF (cosØ), for 3Ø4W, 3Ø3W, 1Ø2W, 1Ø3W.Triple display: KW+V+A easy to read.Recorded each wire parameters of V, A, KW, KVA, KVAR, PF, Hz,total 25 parameters.AC current up to 1000A, AC voltage up to 600V.INRUSH (100mS), HOLD and PEAK functions.MAX and MIN recorded functions.MAX. Cable size: Ø34mm.Auto power off (10 mins), Black-light.EN61010-1, 600V CAT IV, 1000V CAT III.Dimensions: 246mm (H) x 80mm (W) x 43mm(D).

  • Analyzers and Timers

    CAT Advanced Series - Amperis sl

    Description The Advanced CAT Series Analyzers and Timers are stand-alone or PC-controlled digital instruments for circuit breaker status evaluation. Timing channels record arc closing and opening, resistance and auxiliary contacts. The main contact channels can also measure the resistance value of pre-insertion resistors (if present in the breaker). The advanced CAT series records graphs of the opening and closing coil currents and the movements of the moving parts of the high and medium voltage circuit breaker. Test results are printed on the 112 mm (4.4 inch) thermal printer (optional accessory) in tabular and graphical form. The advanced CAT series provides easy selection of different operating modes:

  • Harmonics & Flicker Analyser

    AC2000A - Laplace Instruments Ltd.

    The Laplace Harmonics and Flicker analyser provides the user with a complete system for testing product compliance with IEC61000-3-2 and IEC61000-3-3. Quick and easy to use, the built-in screen provides a clear pass/fail indication of compliance status, plus a full listing of results for each harmonic, in either tabular of bargraph format. The instrument is properly configured to cope with fluctuating harmonics. The Flicker mode provides proper measurement of short term and long term parameters, using algorithms specified in IEC61000-4-15. In addition, inrush current measurements can be automated such that the product under test can be automatically cycled on/off with user entered time profiles.

  • Particulate Filter Management System

    PFS-ONE - HORIBA, Ltd.

    The highly precise weighing of emission particles has become increasingly important due to new legislative regulations such as Euro 6, WLTP, EPA 1066 or PM 10. PFS-ONE, the Particulate Filter Management System offers different weighing methods. This supports full compliance with current legislation in the automotive and environmental industry and also allows for flexibility of internal testing processes. The system covers the measurement, organization, tracking and control of particulate filter weighing. Built as a modular system, the PFS-ONE can be expanded from a stand-alone installation up to a fully integrated laboratory module and can be used for manual weighing or automated weighing via a robot.

  • Wind Direction Sensor

    ENVIROMUX-EWDS - Network Technologies Inc

    Balanced wind direction vane with a near-zero friction bearing and a high accuracy magnetic angle sensor to provide precision wind direction. Sensor range: full 360 degrees , zero deadband. Accuracy: ±1.8 degrees. Resolution: 12 bit or 0.025 degrees. Directional Vane approximately 8 inches (203 millimeters). 3 wire flying leads, 25-feet (7.6-meter). Supply voltage: 4.5 to 5.5 VDC. Current: 15 mA typical. Output: 5 to 95% of input voltage (0.25 to 4.75VDC). Requires the ENVIROMUX-S5VDC-5V to operate with ENVIROMUX-2D/5D/16D. Maximum cable length: 1000 ft (305m)

  • Thermal-Optical Analysis

    Elemental Analysis, Inc.

    As with other current organic carbon and elemental carbon (OC/EC) procedures, Thermal-Optical analysis is method-defined. However, this unit has been designed to specifically address some of the problems observed in other methods in assigning carbon to either the organic or the elemental fraction. By careful system control and continuous monitoring of the optical absorbance of the sample during analysis, this method is able to both prevent any undesired oxidation of original elemental carbon and make corrections for the inevitable generation of carbon char produced by the pyrolitic conversion of organics into elemental carbon. The OC/EC instrument utilized by EAC is used to analyze both bulk samples, and aerosol particles collected on quartz-fiber filters.

  • Camera Modules

    CameraModule - OtO Photonics Inc.

    Series is built with the linear back-thinned 2048 x 64 pixels CCD type sensor and high performance 32bits RISC controller in. CM series contains a Thermal Electric Cooler (TEC) along with cooling system design to reduce dark current and maintain a lower stable operating temperature. CM Series has outstanding sensitivity, high SNR ratio, high dynamic range, low electrical-heat noise and fast spectrum responds, suitable for 785 nm laser 2800 cm-1(790~1010nm) or 3500 cm-1(790~1090 nm) Raman application and long wavelength measurement (180~1100 nm).

  • IR Sensor

    JonDeTech

    The sensor measures a very useful 0.17 mm in thickness and is made of plastic. Essentially it is a piece of robust plastic that can be used “bare” – without protective housing, such as a metal casing commonly used by other producers. The sensor it is less than 0.2 mm. thin and it is made using plastic membrane. This configuration makes the sensor so robust it can be used “bare” – without protective housing such as a metal container. Due to the fact thatSince the sensor chip can be used applied bare, means it can be used in a totally new ways, which can re-defines todays the current view on application design and reduces the cost of the entire system, and not just the sensor-element as such.

  • USB-6525, 16-Channel, 60 V, 8 Solid-State Relays, 8 Inputs, Ch-to-Ch Isolated Digital I/O Device

    779640-01 - NI

    The USB-6525 is an industrial, bus-powered USB I/O device that can automate even the most demanding applications. The solid-state relay outputs are ideal for controlling pumps, valves, motors, and various other industrial actuators. The USB-6525 features channel-to-channel isolated digital inputs that you can use to read from industrial digital sensors, and eight solid-state relay outputs featuring 60 VDC/30 Vrms switching voltage and 500 mA per channel maximum switching current. Using programmable power-up states, you can configure the initial output states in software to ensure glitch-free, safe operations when connected to industrial actuators.

  • 903 Benchtop Three Phase 40A

    Weshine Electric Manufacturing Co., Ltd

    1. The instrument has standard four phase voltage and three-phase current output. It can test not only various traditional relays and protection devices, but also various modern microcomputer protections, especially for transformer differential protection and standby automatic switching device. The test is more convenient and perfect.2. Classic Windows XP operation interface, friendly man-machine interface, easy and fast operation; high performance embedded industrial control computer and 8.4 inch resolution 800 × 600 TFT true color display screen, can provide rich and intuitive information, including the current working state of the equipment and various help information.

  • AC Electronic Load

    IT8600 Series - I-TECH Electronic Co., Ltd

    IT8600 is ITECH latest series of AC/DC electronic loads with power range 0~14.4 kVA and adjustable frequency 45 Hz ~ 450 Hz. The unique oscilloscope waveform display function of IT8600's can display input voltage & current as waveform. It is equipped with measurement modes for different parameters such as inrush current, peak value, effective value, PF (power factor). Voltage harmonics measurement capacity is up to 50th. The built-in RS232, GPIB, LAN and USB communication interfaces are for reliable and fast control. IT8600 is the perfect solution for testing UPS, inverters, AC power supplies and relevant AC electronic components etc.

  • HV Megmeter

    B-1013-6 - ROSS ENGINEERING CORPORATION

    Ross Engineering Corporation’s High Voltage Megmeter® series are unique battery powered DC hipot tester and meter. Models are available for withstand testing of insulation up to 50kV DC, as well as measuring leakage current as low as 0.001 microamp and resistance as high as 30 million megohms when testing underground cable, rubber safety gloves, vacuum interrupters, high voltage devices and all types of electrical insulation. All models have an over current trip feature to minimize arcing damage. Completely portable with rechargeable 12V battery which can be recharged from an automobile or 115V, 230V AC.

  • AC Power Source

    LSP-500VAR - Lisun Electronics Inc.

    • AC-DC-AC frequency conversion technology, Controlled & tested by 16 bits MCU • Protection for over hot, thundering voltage and current • Total voltage distortion: ≤0.3%; Voltage stability: ≤0.05%/30min • Load adjust rate: ≤0.05%; Frequency stability: ≤0.01%/30min • Output voltage range: AC 0.0~300.0V, Output Frequency Range: 45~70Hz, 100Hz, 200Hz and 400Hz • It is pure sine wave AC power source with low harmonic and high accuracy • Input Power: 220V and 50/60Hz (110V can be option) • Communicate with PC via software, the Voltage & Current set by the software and Power Output can be remote controlled.

  • High Voltage Power Supplies

    Guth GmbH

    The mains voltage (230V / 3 x 400V) is transformed, rectified and filtered by the HN series. The direct current output voltage is tuned by a variable transformer or regulated by a thyristor controller. With the HS and HV series the rectified mains voltage is supplied to a frequency converter, which produces a mid-frequency square wave voltage. This transformed, rectified and filtered alternating current produces the desired voltage as output, which is regulated by means of frequency variation or pulse width modulation. The equipment in the HV series supply, in addition to the high voltage output, up to 3 auxiliary outputs which can be used to supply e.g. heating, grid voltage or surge voltage.

Get Help