Showing results: 3706 - 3720 of 5323 items found.
-
WA2660 -
Wuhan Sangao Electrical Test Installations Limit Co.
WA2660 series insulation resistance testing instrument is special use for internal water cooling generator's measurement test. Meanwhile, can also be used in laboratory or field insulation test.The output current is greater than 25mA,Maximum output voltage is 2500V.With high precision micro current measurement system, digital boost system.Only need a high-voltage line and a signal line connecting the sample can be measured.Automatic measurement, the results from the large screen liquid crystal display, and the results are stored.
-
90-200-001 -
Pickering Interfaces Ltd.
Each power outlet can be programmed to switched on in sequence with a specific timing delay. The delay can be staggered to ensure that order dependent systems - like PXI - can be switched on and off in an orderly way with just one operation. A staggered start up also limits the inrush current associated with the powering up of equipment, including earth current inrush, placing less stress on cabling and leakage breakers. Power on or off instructions can be initiated from either the front panel switch or via the serial interface.
-
SWG-12 (SWG-32) -
Kharkovenergopribor Ltd.
• testing cable insulation with DC (rectified) voltage up to 32 kV;• conditioning faults by burning faulty cable insulation with current up to 100 mA;• pre-locating cable faults with the reflectometer RIF-9 based on the pulse reflection method (TDR), voltage wave oscillation method (DECAY), impulse current envelope (ICE) method and arc reflection method (ARC / ARC multi-shot);• pinpointing cable faults with the acoustic method with up to 2000 J surge wave generator and a suitable signal receiver.
-
7128B -
Peaceful Thriving Enterprise Co Ltd
This is a auto-ranging, high accuracy and stable hand held clamp meter to make electrical maintenance safe and easy. With special designed IC to support true RMS, the meter is available to measure AC/DC voltage to 600V, AC current to 600A and resistance to 60MΩ; also having the capability to test diode, continuity and non contact voltage sensing. Sub switch included Function Select, Max-Min Indication, Value Hold, Range Select, Relative Value Measurement, Inrush Current Indication, Illumination and Back-light.
-
72-13610 -
Tenma
*Triple channel linear DC power supply*Dual channel adjustable & one channel fixed*Constant current & constant voltage operation*Forced ventilation & temperature cooling system*LED digital tube display shows voltage and current simultaneously*Low ripple & low noise, output on/off control*Overload and reverse polarity protection*115VAC/230VAC (50Hz/60Hz) AC input voltage and 0.01% high regulation*12-month limited warranty *view Terms & Conditions for details
-
72-13600 -
Tenma
*Triple channel linear DC power supply*Dual channel adjustable & one channel fixed*Constant current & constant voltage operation*Forced ventilation & temperature cooling system*LED digital tube display shows voltage and current simultaneously*Low ripple & low noise, output on/off control*Overload and reverse polarity protection*115VAC/230VAC (50Hz/60Hz) AC input voltage and 0.01% high regulation*12-month limited warranty *view Terms & Conditions for details
-
Electronic Test & Power Systems
Adjustable constant voltage and constant current sources are provided across the entire DC source range. Additionally constant power operation is standard on the high power DC supplies and optional on the medium power models. Modular high current DC power supply systems providing up to 2kV at 2MW can be assembled.A variety of interfaces are available. Analogue, RS232, CAN, RS485, Ethernet or IEEE 488.2 can be specified for most units. LabVIEW drivers are also offered to aid system integration.
-
TAND220A -
Amperis sl
The measuring instrument type TAND220A complies with the international standard IEC 61620. The instrument is based on the so-called "low-amplitude, low-frequency alternating current square wave method" and allows accurate measurements of conductivity and relative permittivity. Conductivity measurement in the range of 0.01 pS/m to 20,000 pS/m allows the use of this instrument for quality control of high resistivity liquids even at room temperature. The TAND220A works with a low test voltage and also with a low test current so that it does not represent a danger for the operators.
-
LXinstruments GmbH
Testing the protective conductor is indispensable for assemblies, devices and systems of protection class I because it reduces the risk of life-threatening electrical accidents.The test checks whether the protective earth (PE) fulfils the criteria specified in the standards and can correctly discharge the current occurring in case of a fault.The ground continuity test checks whether the protective earth conductor is connected continuously to all metallic enclosure parts that can be touched by the user. The test can be carried out with low currents and voltages (simple continuity test).
-
K-3980 -
Kongter Test & Measurement Co., Limited
Kongter offers a series of customized DC load banks with many different models for constant current battery discharge test and battery capacity test. They cover a wide voltage range from 12V to 480V nominal voltages with current up to 600A. They are widely applied in various industries. With its optional battery Data Acquisition Case (DAC), discharge values of EACH cell could be monitored in battery load bank and PC software simultaneously by using Kongter’s data view software.
-
783311-01 -
NI
±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9238 performs differential analog input. The measurement range is compatible with many low-voltage sensors such as current shunts and current transducers in high-current applications. When used with higher-voltage C Series Voltage Input Modules, the NI‑9238 can measure power and energy consumption for applications such as appliance test, industrial machine monitoring, power quality analysis, phasor measurements, and harmonic analysis.
-
DAQ973MB -
Keysight Technologies
The DAQ973MB Better Multiplexer Bundle offer includes a DAQ973A three-slot data acquisition mainframe and three 20-channel DAQM901A multiplexer modules. This bundle provides the following:3-slot mainframe with USB, LAN, and GPIB6.5-digit (22-bit) internal DMM60 channels of multiplexer switches6 channels of dedicated current measurements2- and 4-wire scanning300 V switching80 channels/s scanningbuilt-in thermocouple reference junctionbuilt-in signal conditioning to measure thermocouples, RTDs and thermistors, AC / DC volts and current; resistance, frequency / period, diode test, and capacitance
-
DAQ970MB -
Keysight Technologies
The DAQ970MB Good Multiplexer Bundle offer includes a DAQ970A three-slot data acquisition mainframe and three 20-channel DAQM901A multiplexer modules. This bundle provides the following:3-slot mainframe with USB and LAN6.5-digit (22-bit) internal DMM60 channels of multiplexer switches6 channels of dedicated current measurements2- and 4-wire scanning300 V switching80 channels/s scanningbuilt-in thermocouple reference junctionbuilt-in signal conditioning to measure thermocouples, RTDs and thermistors, AC / DC volts and current; resistance, frequency / period, diode test, and capacitance
-
779781-02 -
NI
100 S/s/channel, 4-Channel C Series Universal Analog Input Module - The NI‑9219 is designed for multipurpose testing. With the NI‑9219, you can measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors, as well as make quarter-bridge, half-bridge, and full-bridge current measurements, with built-in voltage and current excitation. Each channel is individually selectable, so you can perform a different measurement type on each channel.
-
785994-01 -
NI
100 S/s/channel, 4-Channel C Series Universal Analog Input Module - The NI‑9219 is designed for multipurpose testing. With the NI‑9219, you can measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors, as well as make quarter-bridge, half-bridge, and full-bridge current measurements, with built-in voltage and current excitation. Each channel is individually selectable, so you can perform a different measurement type on each channel.