Showing results: 2611 - 2625 of 5366 items found.
-
1668A -
Peaceful Thriving Enterprise Co Ltd
Check on 6 and 12V systems. To indicate whether there is an electrical potential at any low voltage point in the system. By using the pointed contact tip to pierce insulation on cables, it will also indicate if current is present. This can be helpful when tracing faults or add cable to a circuit.
-
1668 -
Peaceful Thriving Enterprise Co Ltd
Check on 6 and 12V systems. To indicate whether there is an electrical potential at any low voltage point in the system. By using the pointed contact tip to pierce insulation on cables, it will also indicate if current is present. This can be helpful when tracing faults or add cable to a circuit.
-
Scientific Research Corp. STI Division
SRC provides threat assessment support focused on cyber threats that may impact the ability to wirelessly link with other systems. This activity supports the development of test and evaluation capabilities important to not only identifying current deficiencies but also for developing next generation systems.
-
all-sun
A DC voltmeter measures the current passing between two points. The normal use of a voltmeter is to check the power in an electrical circuit. Manufacturers install some voltmeters permanently in equipment, but in testing equipment, the voltmeter is generally portable, allowing the user to test different circuits.
-
Vogelsang & Benning
Endurance test bench on which up to five drives can be tested at the same time. The drives / DUTs are electrically connected to resistors and driven by a servo drive according to a predefined driving profile. This exam can take up to several days. It detects currents, speeds and temperatures.
-
8600 -
Tokyo Electronics Trading Co., Ltd.
Basically manual operation bench top Latch-up Tester provides all elements required for the latch-up test such as constant current pulse, programmable power supplies, simple pattern generator, timing generator and pull-up/down function, though some of them are optional.
-
480 -
The Eastern Specialty Company
The RC-50 Artificial Phantom Load with Power Factor (Catalog No. 480) has been re-designed to meet the most exacting requirements. It operates from a single phase source and will deliver current at either unity or 50% power factor at all full load ranges.
-
40-192A-012-HI -
Pickering Interfaces Ltd.
The 40-192A-012-HI is a PXI fault insertion switch with hardware interlock using solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test:
-
Suzhou 3ctest Electronic Co.,Ltd.
Surge pulses occur due to direct or indirect lighting strokes to an external circuit. This leads to current or electromagnetic fields causing high voltage or current transients. Another source for surge pulsed is switching transients originating from switching disturbances and system faults.
-
8PK-ST1520 -
Prokit's Industries Co., Ltd.
Capable of measuring earth voltage (Vac.) 2mA measuring current permits earth resistance to test without tripping earth leakage current breakers in the circuit. Battery operated. Auto power off function. Data hold function. Small and light weight.
-
Nanjing ELIKE Meter Co, Ltd.
Basic functions:AC current: 40/400/1000ADC current: 40/400/1000AAC voltage: 4/40/400/750VDC voltage: 400mV/4/40/400/1000VResistor: 400/4/40/400K/4/40MTemperature: -20 to +750°CFrequency: 10/100/1000Hz/10/100kHz/10MHzDuty cycle: 0.1 to 99.9%Capacitance: 5nF/50nF/500nF/5μF/50μF/200μFSpecial functions:Auto rangingNCVDiodeContinuity buzzerLow battery displayData holdRelative data holdAuto/manual range shiftZeroAuto power-offOverload protectionSampling frequency: 3 times/sMaximum display: 3999Maximum open distance of clamp mouth: 55mmGeneral characteristics:Color: iron gray and orangeNet weight: approximately 274gLCD size: 46 x 32mmSize: 245 x 90 x 33mmPower: 1 x 9V and 6F22Packing content:CartonHandheld bagEnglish manualTesting leadBatteryTemperature probe
-
PDMT25 -
Pyle Audio Inc.
4000 Display CountPeak Capture ModeData HoldMax/Min Recording ModeVoltage DC: Max Range 1000 V, Accuracy +/- 0.5%Voltage AC: Max Range 1000 V, Accuracy +/- 0.8%Current DC: Max Range 10 A, Accuracy +/- 1.2%Current AC: Max Range 10 A, Accuracy +/- 1.8%Resitance: Max Range 40 M, Accuracy +/- 0.8%Duty Cycle: Max Range 99.9%, Accuracy +/- 1.2%Temperature: Max Range 760 C / 1400 F, Accuracy +/- 3.0%Frequency: Max Range 10 MHz, Accuracy: +/- 1.5%Capacitance: Max Range 40 mF, Accuracy +/- 1.5%Diode Check
-
D200 -
Highland Technology, Inc.
The D200 is a compact, DC-coupled fast laser driver, providing up to 4 amps of regulated constant current. A built-in edge-triggered pulse generator produces up to 1 microsecond pulse widths and 2 nanosecond transition times, capable of driving lasers with forward voltages up to 9 volts. A pulse-follower mode is also provided, accommodating externally-defined trigger widths up to 100% duty continuous-wave (CW). Power, pulse width, drive current and differential triggering functions are accessible through a ribbon cable header for embedded OEM applications. A low-inductance laser drive interface permits direct laser connection or custom interposer and flex-cable attachment.
-
CRD-005 and CRD-020 -
Powertek LLC
CRD-020 Programmable ac current set-point relay setting for threshold levels, over and under-currentoperationbullet CRD-005 Programmable dc voltage and mA set-point relay setting for threshold levels, over and under-voltage operationbullet CRD-005 internal DIP-switches allow for either 0-1mAdc or 0-10Vdc operation, and may be set for under-alarm or over-alarm relay operationbullet CRD-020 internal DIP-switch allow configuration of the ac current range to either 0-5A, 0-10A, 0-15A or 0-20A and the relay mode for under-current or over-current operationbullet Lid mounted two digit numerical push button switch calibrated as percent of full scale with a threshold range of 1-99%bullet Red LED lamp lights to indicate when the threshold level has been tripped
-
Columbia Research Laboratories
Columbia offers a wide variety of Signal Conditioning Instrumentation for a variety of Sensor types. These range from Laboratory as well as Airborne Charge Amplifiers, Differential Charge Amplifiers, In-Line Charge Converters, Constant Current Power Supplies and ICP Compliant Amplifiers all in support of Columbia's extensive Piezoelectric product line. Additionally Columbia offers unique Strain Gage Instrumentation Amplifiers which provide built in auto zeroing of gage offset voltages which can increase typical measurement accuracies. These robust Signal Conditioning products have been flight qualified on many current military aircraft and missile programs and are now available for your distinctive program needs.