Showing results: 2221 - 2235 of 5317 items found.
-
APCI-7500-3/4C -
TEAM SOLUTIONS, INC.
*This model has 4x 9-pin D-Sub male connectors on 2 brackets*RS232, RS422, RS485, 20 mA Current Loop*Modular structure through SI modules*With or without optical isolation*Mode configuration free for each port*128-byte FIFO-buffer, common interrupt*Transfer rate programmable up to 115,200 Baud*Option: up to 1 MBaud for RS485 and RS422*Automatic direction recognition for RS48*Mode: configurable RS232, RS422, RS485, 20 mA Current Loop (active, passive) with or without isolation (SI modules)
-
PCE Instruments
With certain models of cable detectors you can locate open power cables, either live or dead (without current), with voltages up to 300V. Cable detectors can locate cables, circuits, short circuits and ground points. To perform these functions, it is not necessary to disconnect electrically sensitive devices or to disconnect theCable Detectors to locate open power cables, either live or without current, up to 300V power from the cable which is being tested. Cable detectors can also locate ferrous and non-ferrous metals, wood and plastic with a high level of accuracy.
-
Kikusui Electronics Corp.
high performance electronic load is the successor to the highly respected PLZ-4W series, whilst still retaining the same high specification and build quality. Advances include a high visibility color display, low voltage operation from a minimum of 1 V to a maximum of 150 V. Programmable profiles of voltage/current can be applied (using the new ARB function, as used in LED/solar testing) in addition to the inherited 6 modes of operation: Constant Current, Constant Resistance, Constant Voltage, Constant Power, Constant Current + Constant Voltage, Constant Resistance + Constant Voltage.
-
PLZ-5W/5WZ Series -
Kikusui Electronics Corp.
The PLZ-5W Series high performance electronic load is the successor to the highly respected PLZ-4W series, whilst still retaining the same high specification and build quality. Advances include a high visibility color display, low voltage operation from a minimum of 1 V to a maximum of 150 V. Programmable profiles of voltage/current can be applied (using the new ARB function, as used in LED/solar testing) in addition to the inherited 6 modes of operation: Constant Current, Constant Resistance, Constant Voltage, Constant Power, Constant Current + Constant Voltage, Constant Resistance + Constant Voltage.
-
CPL 2 -
Borgtech Pty Ltd.
The CPL2 is a robust IP68 submersible, wireless mini logger designed to record AC/DC Voltages and Currents. CPL2 is designed to work with applications such as monitoring of corrosion (i.e. stray current surveys), for the purpose of identifying whether an asset is protected or is in need of maintenance. The hardware module is self contained and provides interval based monitoring and recording . The data can be viewed and exported to proprietary or industry standard CSV or TXT file formats for use in a wide variety of other applications. Also export for those requiring the VEC (Victorian Electrolysis Commission - Australia) compliant file format.
-
SEN-39001 -
Playing With Fusion Inc
Breakout board for the AS3935 digital lightning sensor based on the AMS reference design. Includes specially tuned antenna, SPI or I2C interfacing, and a wide 2.4V to 5.5V standard operating range. This innovative sensor is designed to interface with most current development systems and boards, including all current Arduino modules. The breakout board features an inductor (antenna) specially designed for this application, and the board ships fully calibrated. This ensures that you don't have to write a massive back-end to support low-level IC calibration, just focus on your final application!
-
9841 -
PRODIGIT Electronics Co, Ltd.
*Easy user interface*Measure Voltage, Current, Power, KWH, AH, Temperature, Reference Voltage*Accuracy Measure Time*Easy to see now test progress*Can cycle test*Provide Charge, Discharge, Suspend, FOR, LOOP Mode Select*When Charging, set the stop current to stop charging when fully charged so as to avoid overcharging that will damage the battery. When Discharge, set the stop voltage to stop discharge when discharging to lowest so as to avoid over-discharging that will damage the battery. *The test result will be stored to ACCESS data
-
Carl E. Holmes Company
- Regulated Power Supply, 9.6 KW P/N 5944C2- Input: 220 VAC, 3 PH, 50/60 Hz- Output: 0 to 24 VDC, 400 Amps max- Duty factor: 100%- Ripple voltage: <3% across full output range- Setting: 0 – 100% current and voltage- Control: Constant current and voltage control- Ambient temperature: up to 95 degrees F- cooling: Forced air-cooled- Dimension: 17.6″H x 19.9″W x 21.6″D- Weight: 175 lbs.- Degree of protection: NEMA 2
-
DIR CT -
Scope T&M Pvt, Ltd.
SCOPE proudly introduces Dir CT, a CT Polarity Tester specially designed to verify correctness of polarity of current transformers cores in live EHV switchyards. Polarity test is one of the most common yet crucial tests required to be done on current transformers by commissioning as well as maintenance engineers. Even though it is commonly conducted check, there was no all in one simple tool available for this measurement. DIR CT fills this void to perfection, it is expected to significantly reduce the time taken for polarity checks on numerous CT in sub-station, especially during commissioning of new sub-stations
-
CPX Series -
Aim-TTi
PowerFlex design gives variable voltage and current combinations within a maximum power rangeUp to 60 volts and up to 20 amps180 watts or 420 watts maximum per outputIsolated outputs can be wired in series or parallelConstant voltage or constant current operationSettings Locking (S-Lock)PowerFlex or fixed-range operationVariable OVP tripsSelectable remote sense terminalsCompact quarter or half rack 3U case sizeIsolated analogue remote control (CPX400SA only)RS232, USB & LXI compliant LAN (P models only)GPIB Option (P models only)
-
APCI-2016 -
TEAM SOLUTIONS, INC.
16 isolated output channels, 10 to 36 V,. Output current 500 mA? Timer-programmable watchdog for the reset of the outputs to ì0î? One ground line for all outputs? At Power On/Reset, the outputs are set to "0"
-
EC997 MC/QUAD -
Mustang Dynamometer
Factory Pro and Mustang''s MC/QUAD Dyno is a specially designed, high-speed, low-inertia motorcycle/QUAD/Kart combination dyno. The low inertia design and eddy current loading features are perfect for precision tuning and diagnostic applications.
-
HIOKI E.E. Corp
Designed for 50/60 Hz commercial line use 3 circuits (1P2W), single circuit (1P3W, 3P3W, 3P4W) Save data to the SD card continuously (Current) Clamp input (Voltage) Non-metallic contact sensor
-
STDE -
Altanova Group
This option allows neutralizing the residual magnetization of the power transformer core after the winding resistance test. The principle of the option is to apply a constant current of alternate polarities to the transformer winding, as per the IEEE 0062 1995 standard.
-
4B -
Dwyer Instruments Inc.
The Series 4B 1/4 DIN Temperature/Process Controller is designed to accept thermocouple, RTD, current or voltage input and provide dual outputs for control. Available outputs include relay/relay, voltage pulse/relay, current/relay, or linear voltage/relay