Filter Results By:

Products

Applications

Manufacturers

Showing results: 526 - 540 of 580 items found.

  • GPIB-RS485/RS422 GPIB Instrument Control Device - Brazil 127-220VAC

    779733-12 - NI

    The GPIB‑RS485 is an IEEE 488 controller device for PCs with RS485 or RS422 ports. You can use this device to integrate an instrument into your system using GPIB. This device transforms a computer with an RS485 or RS422 serial port into a talker, listener, or controller on the GPIB bus. It can also interface RS485 and RS422 instruments and peripherals to the GPIB bus. It can implement the physical and electrical specifications of the IEEE 488, RS485, and RS422 standards, as well as interpret and execute high-level commands from the serial port, including serial‑to‑GPIB, and GPIB‑to‑serial protocol conversions. This device is IEEE 488.2 compatible. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

  • GPIB-RS485/RS422 GPIB Instrument Control Device - Taiwan 110VAC

    779733-11 - NI

    The GPIB‑RS485 is an IEEE 488 controller device for PCs with RS485 or RS422 ports. You can use this device to integrate an instrument into your system using GPIB. This device transforms a computer with an RS485 or RS422 serial port into a talker, listener, or controller on the GPIB bus. It can also interface RS485 and RS422 instruments and peripherals to the GPIB bus. It can implement the physical and electrical specifications of the IEEE 488, RS485, and RS422 standards, as well as interpret and execute high-level commands from the serial port, including serial‑to‑GPIB, and GPIB‑to‑serial protocol conversions. This device is IEEE 488.2 compatible. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

  • Edge AI Box

    EPC-R5710 - Advantech Co. Ltd.

    Advantech EPC-R5710 is an AI edge intelligent industrial gateway integrating NXP's high performance of video coding/decoding and AI function. It can provide 2.3-28.3 TOPS NPU AIcomputing power, and support multiple network ports, a variety of industrial interfaces and storage, as well as wireless technologies including 5G/4G,Wi-Fi5/6. It also supports 8-wayMIC array to realize audio and video AI analysis. Integrated cloud collaboration functions.EPC-R5710 supports a variety of PLC data acquisition and industrial protocol conversion. With its high performance and high quality, it is widely used in AI video surveillance, machine vision and industrial data acquisition applications in the fields of security, smart city, smart transportation, smart factory, energy and power.

  • Advanced Test Platform

    980 12G - Teledyne LeCroy quantumdata

    The Teledyne LeCroy quantumdata 980 12G-SDI Video Generator / Analyzer module supports video and audio functional testing of next gen broadcast monitors, conversion devices and sources up to 12G-SDI. The module is equipped with four (4)12G-SDI-capable output ports. The output ports can be aggregated for Dual link HD-SDI and Quad link 3G-SDI operation. A genlock input supporting both SD analog black burst and HD tri-level to sync the output clocks with a "house sync" but the module can also run off its internal clock. The module's four (4) SDI input ports can also be aggregated for Dual link HD-SDI and Quad link 3G-SDI operation. For single link operation only port 1 on the input or output is functional.

  • Solar Cell Testers

    Photo Emission Tech., Inc.

    Solar Cell Testers are integrated systems incorporating Solar Simulator and I-V Measurement systems. PET offers Standard and Advance IV Measurement software. PET Cell Testers are capable of measuring a diverse range of solar cell parameters such as Isc,Voc, Imax,Vmax, Pmax, FF, Rsh, Rs and η cell conversion efficiency, complete light and dark I-V curves. All that needs to be done to test a cell is to load the cell, make electrical probes contact and press “Measure” icon on the I-V Measurement System software. The software will automatically open the Solar Simulator shutter, perform the test and close the shutter after the test is complete. The design is modular in nature and can be easily upgraded. Some options can added at a later time.

  • Large-Displacement Low-Frequence Vibration System

    9363-LN-100 - King Design Industrial Co., Ltd.

    This tester is designed to assess the damage made to product packaging and internal objects caused from transporting environment; to discover the packaging flaw and product’s early failure from a long-term cumulative vibration fatigue; avoid man-made transporting damage and improve product’s reliability and quality of delivered products. With the use of high-performance foot absorber, the resonance effect to floor caused by the bounce test may be waived; and can reduce the pile’s destruction to industrial plants. Two displays can make comparative display on both frequency and rpm at the same time; thus no need to switch in order to read these two values. The dual-control mode of time accumulator and counter can avoid human error resulting from the conversion. Easy to operate; no need for complicate training program.

  • GPIB-RS485, GPIB Instrument Control Device

    779733-04 - NI

    Serial, RS485/RS422 GPIB Instrument Control Device - The GPIB‑RS485 is an IEEE 488 controller device for PCs with RS485 or RS422 ports. You can use this device to integrate an instrument into your system using GPIB. This device transforms a computer with an RS485 or RS422 … serial port into a talker, listener, or controller on the GPIB bus. It can also interface RS485 and RS422 instruments and peripherals to the GPIB bus. It can implement the physical and electrical specifications of the IEEE 488, RS485, and RS422 standards, as well as interpret and execute high-level commands from the serial port, including serial‑to‑GPIB, and GPIB‑to‑serial protocol conversions. This device is IEEE 488.2 compatible. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

  • GPIB-RS485/RS422 GPIB Instrument Control Device

    779733-02 - NI

    Serial, RS485/RS422 GPIB Instrument Control Device - The GPIB‑RS485 is an IEEE 488 controller device for PCs with RS485 or RS422 ports. You can use this device to integrate an instrument into your system using GPIB. This device transforms a computer with an RS485 or RS422 serial port into a talker, listener, or controller on the GPIB bus. It can also interface RS485 and RS422 instruments and peripherals to the GPIB bus. It can implement the physical and electrical specifications of the IEEE 488, RS485, and RS422 standards, as well as interpret and execute high-level commands from the serial port, including serial‑to‑GPIB, and GPIB‑to‑serial protocol conversions. This device is IEEE 488.2 compatible. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

  • GPIB-RS485 RS422 GPIB Instrument Control Device

    779733-01 - NI

    Serial, RS485/RS422 GPIB Instrument Control Device - The GPIB‑RS485 is an IEEE 488 controller device for PCs with RS485 or RS422 ports. You can use this device to integrate an instrument into your system using GPIB. This device transforms a computer with an RS485 or RS422 serial port into a talker, listener, or controller on the GPIB bus. It can also interface RS485 and RS422 instruments and peripherals to the GPIB bus. It can implement the physical and electrical specifications of the IEEE 488, RS485, and RS422 standards, as well as interpret and execute high-level commands from the serial port, including serial‑to‑GPIB, and GPIB‑to‑serial protocol conversions. This device is IEEE 488.2 compatible. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

  • 28-CH PPI Module

    ND-6058 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • 3-CH RTD Input Module

    ND-6013 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • 15-CH Isolated Digital Output Module

    ND-6056 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • 8-CH Analog Input Module

    ND-6017 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • 8-CH Relay Output Module

    ND-6063 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • RS-422/RS-485 Repeater

    ND-6510 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

Get Help