Showing results: 2086 - 2100 of 2633 items found.
-
1105 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
4105 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
2105 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
1805 ER -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● Test test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Battery check function.● Calibration performed with supplied test leads.
-
2120 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● 0Ω adjustment.● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads.
-
2705 ER -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Battery check function.● Calibration performed with supplied test leads.
-
Megger Group Ltd.
The need for a comprehensive current transformer testing regime is evident when the alternative is considered: a catastrophically damaging current transformer fault. A fault leading to an open secondary could cause the primary current to overwhelm the insulation, causing the winding to short circuit. Megger’s range of current transformer test equipment allows you to construct an in depth test and maintenance programme to prevent problems before they occur.
-
300 Series Benchtop ATE -
Circuit Check, Inc.
The Circuit Check 300 Series benchtop ATE Test Platform with built-in professional fixturing solves the uncertainty of repeatable results that are common with bench testing. With the 300 Series Benchtop ATE, test procedures can become automatic, with test steps and go/ no-go limits easily programmable in common tabular form. Hand-probing is eliminated, replaced with accurate, repeatable tooling and reliable spring-loaded test probe fixturing.
-
PCMT20 -
Pyle Audio Inc.
Measures AC and DCMax. Resolution to Current Measurement: 0.1uALCD Display with BacklightData Hold, Zero Function, Auto Power OffLower Battery Indiactor0.9' (23mm) Jaw SizeDC Voltage: Range: 0-600 V; Accuracy: +/- 0.5%AC Voltage: Range: 0-600 V; Accuracy: +/- 1.5%AC Current: Range: 0-400 A; Accuracy: +/- 3.0%Resistance: Range: 0-40 M; Accuracy: +/- 3.0%Temperature: Range: 1000 C / 1832 F; Accuracy: +/- 3.0%Capacitance: Range: 100 uF; Accuracy: +/- 2.5%Frequency: Range: 150 kHz; Accuracy: +/- 1.2%Continuity: Buzzer Sounds at 100Diode: Test Current 0.3mA; Open Circuit Voltage 1.5VBatteries: 2 x AAA IncludedAccessories Included: Black Bag, Test Leads, Type K Temperature ProbeDimensions: 8.07' H x 2.36' W x 1.18' DWeight: 7.94 ozSold as : Unit
-
CS-48-100 -
Hypres, Inc.
The Model CS-48-100 is a multi-channel, programmable current source. Developed for both semiconductor and digital superconductor electronics, it is computer-controlled and features 48 low noise current source outputs. Each source output has the capability to both set and read back currents and can be set to a zero current high Z mute state. Each of the 48 sources are optically coupled for control and are sourced from their own secondary winding for complete galvanic isolation. The device consumes a maximum of only 80 W and handles a maximum load current of 4.8 A total over all outputs. Operating over a range of 0-100 mA on each channel, the device features accuracy of +/-25 ?A. The mute state can be set thru a rear panel interlock or from the front panel button for maximum circuit protection. The unit can be mounted in a standard-sized rack.
-
Model T200U NOY -
Teledyne Advanced Pollution Instrumentation
The Model T200U NOy analyzer has been developed and refined specifically to address the challenges of NOy monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is coupled with a remote NOy converter via umbilical to allow measurements with a lower detectable limit of 50 ppt.The Model T200U NOy analyzer combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer. The remote NOy converter is provided with a stainless steel, NEMA 4X (IP65) enclosure and custom sample umbilical to allow a mounting height of 10 meters. In addition, the converter features a unique purge circuit designed to remove residual calibration gas.
-
RMO TT Series -
Amperis sl
The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.
-
Handyscope HS6 DIFF -
TiePie engineering
This powerful USB 3.0 super speed oscilloscope combines fast sampling up to 1 GS/s with high resolutions of 12, 14 and 16 bit and a large memory of 64 MSamples on all four channels. The oscilloscope supports continuous streaming measurements up to 200 MS/s and can be synchronized with other oscilloscopes using the CMI interface to form a multi channel combined instrument with synchronized timebase. The CMI interface is available by default on the Handyscope HS6 DIFF. Optionally, the Handyscope HS6 DIFF can be delivered with SureConnect connection test and resistance measurement on each channel. Also, the Handyscope HS6 DIFF can be delivered with SafeGround option. With SafeGround you can switch the differential inputs of the Handyscope HS6 DIFF into single ended inputs with ground protection. It allows to make measurements using standard attenuating probes and protects the scope when a short circuit to ground is created.
-
Series C75-2 -
Teledyne Defense Electronics Relays & Coax Switch
Series C75-2 solid-state relays are packaged in a 16-pin DIP, with surface-mount or through-hole mounting available. They utilize a power FET switch that is protected against overload and short-circuit currents. 2S versions provide an open-collector trip status feedback to the relay’s control side. 2SH versions add an internal transient voltage suppressor for inductive loads.MSL 6C75 relays are controlled with 4.5-5.5VdcC = Through-hole mount SC = Surface mountAvailable options include:C75-2 1A, 60Vdc Load; short-circuit protectionSC75-2 1A, 60Vdc Load; short-circuit protection C75-2S 1A, 60Vdc Load; short-circuit protection and trip satusSC75-2S 1A, 60Vdc Load; short-circuit protection and trip status C75-2SH 1A, 60Vdc Load; short-circuit & transient voltage protection, and trip statusSC75-2SH 1A, 60Vdc Load; short-circuit & transient voltage protection, and trip status
-
DP-VXI-4017 -
Data Patterns Pvt. Ltd.
DP-VXI-4017 is an 80 Channel Relay Multiplexer constructed using ‘2 Form A’ (DPST) relays. It is a ‘C’ size 1 slot register based VXI module. This 80 Channel Relay Multiplexer module is highly configurable. As an 80 channel multiplexer, one input can be multiplexed to any of the 80 outputs or vice versa. The 80 channel multiplexer is divided into 8 banks of 10 channels each. This combination allows the board to be used as one group of 80x1 or two groups of 40x1 or four groups of 20x1 or eight groups of 10x1 differential multiplexer. The banks are isolated from each other by tree switches. 8 tree switches are used, one tree switch for each bank. A common tree switch is used to group all the eight banks. For short circuit protection resistors are provided for all the common terminals.