Filter Results By:

Products

Applications

Manufacturers

Calibration

maintains accuracy of test asset by correcting out of specification conditions.

See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References


Showing results: 1426 - 1440 of 1904 items found.

  • E-Series Average Power Sensor

    E9301A - Keysight Technologies

    Measure the average power of all modulation formats Wide dynamic range (-60 dBm to +20 dBm) and frequency range 10 MHz to 6 GHzHigh maximum power specification Low SWR for reducing mismatch uncertainty Calibration factors linearity and temperative compensation data stored in EEPROM Fast measurement speeds (up to 400 readings per second with the Keysight E4416A)Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters

  • Blackbody / Reference Infrared Source

    HGH Infrared Systems

    Blackbodies are reference sources used for testing infrared systems. They are required in industry for calibration of pyrometers, infrared line scanners or cameras. In laboratories, they are part of benches for characterisation of complex optronic systems. HGH offers a wide range of blackbodies to cover all Customers needs.

  • Single Phase Double Channel Energy Meter Test Equipment

    SY8126 - Hong Kong Songyang Industrial Ltd.

    SY8126 single phase Energy Meter Test Equipment is a new generation, high precision, energy meter calibration equipment. It uses the international’s most advanced technology and components available in 90 decade. The equipment works under the control of keyboard or remote computer.

  • NI Semiconductor Test Systems

    NI

    The STS delivers the openness and flexibility of the NI PXI platform to the semiconductor production environment. For easy integration into the production test cell, the STS comes with features such as handler/prober integration, spring probe device under test interfacing, STDF data reporting, and system calibration.

  • Field Strength Meters

    FIM-22 And FIM-41 - Potomac Instruments, Inc.

    The Models FIM-22 and FIM-41 are portable field strength meters designed to provide precise, direct measurements of electro-magnetic fields in the 200 kHz to 5.0 MHz spectrum. These units include a receiver, integral shielded loop antenna, precision attenuator, internal calibration source, and battery power supply. With calibration accuracy traceable to the National Institute of Standards and Technology, the FIM-22 and FIM-41 meet the most exacting requirements of government and industry. Their hinged covers, on the rugged drawn aluminum cases, contain a loop antenna. Opening the cover to a vertical position connects the antenna terminals to the receiver via maintenance-free gold-plated contacts. An interlock switch prevents inadvertent battery discharge when the cover is closed.

  • Bench-top Optical Light Source

    STC-BTOLS2201 series - Shanghai Stone Communication tech Co., Ltd

    STC-BTOLS2201 series high stable Bench-top light source are microprocessor controlled laser diode sources which can support the variety of emitters such as: DFB,FP,PUMP,SLED etc. It is specially used in passive components testing, power meter calibration and general laboratory uses.

  • Current Sensing

    Texas Instruments

    voltage-output, current-sensing amplifier family that integrates an internal shunt resistor to enable high-accuracy current measurements at common-mode voltages that can vary from 0 V to 36 V, independent of the supply voltage. The device is a bidirectional, low- or high-side current-shunt monitor that allows an external reference to be used to measure current flowing in both directions through the internal current-sensing resistor sensor. The integration of the precision current-sensing resistor provides calibration equivalent measurement accuracy with ultra-low temperature drift performance and ensures an optimized Kelvin layout for the sensing resistor is always obtained.

  • Direct Reading Attenuator with Remote Control

    DA2XE - Elmika

    DA2XE Millimeter-Wave Direct Reading Attenuator is a measurement instrument for signal level setting or loss measurements in waveguide networks. It also can be used for calibration of other attenuation measurement instruments. Direct Reading Attenuators have rotary-vane design. The value of attenuation is determined by rotation angle of resistive film with respect to the waveguide channel. Attenuation value does not depend on frequency. The attenuator has electronic control. The attenuator can be used in local or remote (via USB 1.1 or higher) operation modes.The Attenuators are provided in waveguide bands between 18 GHz and 225 GHz.

  • Industrial Temperature Sensors

    AMETEK Sensors, Test & Calibration

    Temperature measurement and calibration is our specialty, allowing us to provide much more than just standard sensors and assemblies. Our long experience, developing and producing industrial temperature sensors, provides us with a wide knowledge about applications and customer needs. This enables us to build and deliver quick and custom-designed quality temperature sensors for almost any kind of solutions and applications, no matter what industry. We offer a complete range of thermocouple assemblies and resistance thermometers, as well as thermocouple wire, extension wire, temperature transmitters and accessories.

  • Mechanical Force Gauges

    IMADA, Incorporated

    Imada mechanical force gauges are highly accurate instruments used to test the quality, strength or functionality of component parts or products. Imada mechanical force gauges check both compression and tension (push or pull). Peak force can be captured using the peak indicator needle and the tare ring compensates for the weight of attachments. Imada force gauges are constructed with a heavy-duty metal case and all metal components to enable them to retain their calibration for years with proper care. These mechanical force gauges never need charging or batteries and are intrinsically safe in hazardous environments.

  • Nanotesla Meter

    RM100 - Macintyre Electronic Design Associa

    The RM100 uses a differential measurement technique employing two subsystems to achieve its high accuracy. The first subsystem is a user controlled field neutralization unit with a dynamic range of ±100,000 nT and a resolution of 0.1 nT. The second is a low noise analog output magnetometer that measures the difference between the ambient and neutralization fields. The neutralizing field and difference field are displayed on a large Vacuum Florescent Display on the front panel. The difference field is also provided as an analog voltage through a connector on the back of the chassis. The factory calibration of the neutralization subsystem to ±0.01% is traceable to NIST.

  • Shuttle Bus VMC Intelligent Interface Card

    IIB-SB-VME - Western Avionics Ltd.

    The Shuttle Bus VME is an intelligent interface card providing all Launch Data Bus, Ground Data Bus, andMultiplex De-Multiplex Multiple Remote Terminal capability to the Shuttle Bus, as required by NASA specification84K01203 (Hardware Specification, Launch Data Bus (LDB) and Ground Data Bus (GDB) Interface Board).In summary, this card provides all features and functions required to meet the above specification, in a VMEplatform, with Simplex & Half-Duplex modes provided. Specific operational modes provided include LDB_BCT,LDB_MRT, GDB_BCT, GDB_MRT, BUS_MON, MDM_MRT, Primitive and Calibration modes.

  • Software

    Junction Measurement and Analysis - Materials Development Corporation

    A comprehensive set of analyses for junction diode or Schottky barriers begins with C-V data gathering that adjusts the voltage step to the slope of the C-V characteristics. This assures an optimum set of C-Vdata whether the voltage range is small or large. Doping profile and resistivity profile are both available at the touch of a key. Plots of 1/C2 - V or Log(C) - Log (V+ phi) show doping uniformity and doping slope factor. Exclusive recalculation options allow adjustment of stray capacitance and area to facilitate calibration using a standard reference wafer of known doping or resistivity.

  • Ultrasonic Level Transmitter

    USonic - AMETEK Drexelbrook

    The Drexelbrook family of Ultrasonic technology level products offers an affordable two wire and line powered version for non-contact level measurement of liquids and slurries for level, distance, volume and open channel flow.Measurements of level, distance, volume and open channel flow is easily configured through the menu driven display. The Usonic level transmitter is offered with a two wire 4-20 mA, Hart output signal and is suitable for all Class I Div. 1, Zone 0, I.S. or XP locations. The bench configuration eliminates the need to move process material levels for calibration.

  • Impedance Standards and Calibrators

    MEATEST, s.r.o.

    Impedance Calibrator is to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car. The calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network. Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter. OPEN and SHORT reference positions are available as well.