Filter Results By:

Products

Applications

Manufacturers

Calibration

maintains accuracy of test asset by correcting out of specification conditions.

See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References


Showing results: 1321 - 1335 of 1905 items found.

  • Handheld Optical Power Meter

    X5001 - Shinho Company

    Optical power meter X-5001 is designed to meet the high demand. It intergrades the handheld optical power meter and the intelligent optical power meter in one unit. It can be used for the absolute power measurement and relative measurement of the link loss in dB. Its compact size, friendly operation interface, broad power measurement range, high precision and brand-new user automatic calibration function and high performance in application makes it an ideal tool for optical fiber network.

  • Intelligent Pressure Calibrator

    Huaxin instrument (Beijing) Co., Ltd

    Here at Huaxin, we offer a selection of HS602 and HX601B intelligent pressure calibrators. They are high pressure, single range digital pressure calibrators with HART communication capability. Composed of high precision measurement chip, 24V DC power supply, battery charging protection circuit, HART communication module and intelligent digital pressure module, these two pressure calibrators provide a pressure calibration solution for gauges, transmitters, and switches over a wide pressure range.

  • Mobile sound Level Meter

    SoundMeter - Faber Acoustical, LLC

    SoundMeter turns your iOS device into a handheld sound level meter (SLM) with support for exponential-time-weighted sound level (Lp) and equivalent sound level (Leq) measurements with various time and frequency weightings. The built-in signal generator tool can be used for generating calibration test tones, noise, chirps, or other periodic signals. SoundMeter also offers additional tools via in-app purchase, including a Noise Dosimeter and a whole or 1/3-octave real-time analyzer.

  • PDL/IL Multimeter

    PDL-201 - General Photonics Corp.

    The PDL-201 uses a patented maximum and minimum search method compliant with TIA/EIA-455-198 to simultaneously measure the Polarization Dependent Loss (PDL), Insertion Loss (IL), and optical power of devices in just 30 ms. Unlike PDL meters that use the polarization scrambling method, the PDL-201's max-min technique is useful for both low and high values of PDL. And unlike instruments that use a Mueller Matrix technique, the PDL-201 has a wide wavelength range without calibration.

  • Power Probes

    RkP-400 Series - Laser Probe Inc.

    The RkP-400 Series probes consist of a compact head containing the detector and a preamplifier housed in a separate enclosure. The external dimensions of all the 400 Series Probes are the same, with identical detector planes, allowing for easy interchange of probes in an experiment. The heads have both ¼-20 and M6 tapped holes, a built-in 1” (25mm) filter holder, and a side-mounted BNC connector. Probe specific data, including spectral response curves and calibration dates, is stored in the preamplifier for access by the instruments.

  • Propeller Meters

    Sparling Instruments

    Measures accurately over a flow range of 10:1 or greater.± 2% of rate accuracy, guaranteed by certified wet calibration at three test points in.Sparling’s National Institute of Standards and Technology (NIST) traceable hydraulic flow lab.Sturdy cast or fabricated steel construction.Operating temperatures are over 100° F(unless higher temperature construction is specified).Suspended solids are over 0.5% of volume.Easily maintained with standard tools.Registration can be furnished in any standard Engineering Unit.

  • Radon Professional Monitoring

    Bertin Instruments

    Our dedicated range of products and accessories has been especially designed to fit these needs and to provide accuracy in the following application fields: Short and long-term monitoring of radon concentration indoor and outdoor, water and soil gas analysis Radon surveillance and mitigation at workplaces (according to valid radiation protection regulations) Geological survey, e.g. vulcano watching, earthquake surveillanceAlphaGUARD products reputation is worldwide recognized, as a reference device for calibration for active and passive radon detectors.

  • RTD and Thermocouple Calibrator

    PTC-8010 - Martel Calibrators

    This RTD and Thermocouple Calibrator is an ideal device to handle all of your temperature calibration needs in a truly rugged, low-cost package. It combines virtually all widely used thermocouples and RTDs in one device - you'll never have to worry about finding a temperature device you can't calibrate. This is especially true when calibrating "smart" or pulsed RTD transmitters, where many other rtd calibrators fail to work or operate at reduced accuracy specs.

  • Temperature Switches

    Analog Devices Inc.

    Analog Devices trip point temperature switches monitor temperature and activate digital output when measurements exceed the trip point setting. To meet differing design needs, we provide pin selectable, factory set, and user programmable trip point setting options. With support for a wide range of operating temperatures and without the need for external calibration, our portfolio of temperature switches also enable swifter design and production with faster time to market.

  • University Kit

    Copper Mountain Technologies

    Copper Mountain Technologies’ University Kit is a complete solution designed to assist educational institutions as they teach RF skills to engineering students. The kit has three options of vector network analyzer models in 3 GHz or 8 GHz frequency range and includes the calibration module, a few devices under test (DUTs), and accessories necessary for an array of common VNA measurements. The kit also includes sample laboratory curriculum for teaching using the tools in the kit.

  • VELOCICALC Multi-Function Ventilation Meter

    9565-P - TSI Inc.

    The portable, handheld VELOCICALC® Multi-Function Ventilation Meter 9565-P features a menu-driven user interface for easy operation in your local language. On-screen prompts and step-by-step instructions guide the user through instrument setup, operation, and field calibration. The 9565-P also features an ergonomic, overmolded case design with probe holder and a keypad lockout to prevent tampering during unattended use. The 9565-P model has a differential pressure sensor and does not include a probe.

  • Averaging Clip-on Extensometer

    Instron

    The Instron 2650 Series Biaxial Extensometers are ideally suited for testing a wide range of materials, including polymer matrix composites, metals, and plastics over a range of temperatures. Two sensors measure axial strain on opposite sides of the specimen. Versions are available which provide either a single averaged axial output or 2 independent axial outputs. The extensometers meet the calibration requirements of ASTM E83 class B1, ISO 9513 class 0.5, and ISO 527.

  • PXI Strain/Bridge Input Module

    NI

    PXI Strain/Bridge Input Modules feature up to eightchannels that support quarter-, half-, or full-bridge sensors at speeds up to 102.4kS/s. The modules provide increased accuracy, high data throughput, and a range of synchronization features. Optional features include remote sensing, internal bridge completion, and shunt calibration options per channel. PXI Strain/Bridge Input Modules are ideal for dynamic strain, load and pressure measurements, and test cell installations requiring accuracy and flexibility.

  • Energy Probes

    RjP-400 Series - Laser Probe Inc.

    The RkP-400 Series probes consist of a compact detector assembly, or head, and a preamplifier housed in a separate enclosure. The external dimensions of all the 400 Series Probes are the same, with identical detector planes, allowing for easy interchange of probes in an experiment. The heads have both ¼-20 and M6 tapped holes, a built-in 1" (25mm) filter holder, and a side-mounted BNC connector. Probe specific data, including spectral response curves and calibration dates, is stored in the preamplifier for access by the instruments.

  • Acoustic Calibrators

    Castle Group Ltd.

    When you're ready to take noise measurements, it's strongly recommended that you perform a field calibration using an Acoustic Calibrator. You should calibrate your sound meter before you start to measure, and then once you've finished you should perform a reference check against the calibrator and make note of any drift that has occured. You can find out more about performing Field Calibrators by reading this post and watching a short video.

Get Help