Filter Results By:

Products

Applications

Manufacturers

Calibration

maintains accuracy of test asset by correcting out of specification conditions.

See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References


Showing results: 1261 - 1275 of 1906 items found.

  • Fast Response Flow Controller for Medium Flow

    HFM-301 / HFC-303 - Teledyne Hastings Instruments

    The HFM-301 / HFC-303 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a choice of elastomers and high pressure options, the HFM-301 / HFC-303 services a wide variety of applications. Cleaning for oxygen service is available.

  • E-Series Average Power Sensor

    E9300B - Keysight Technologies

    Measure the average power of all modulation formats Wide dynamic range power measurements from -30 dBm to +44 dBm Frequency range 10 MHz to 18 GHzLow SWR for reducing mismatch uncertainty Calibration factors, linearity and temperature compensation data stored in EEPROM Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters

  • E-Series Average Power Sensor

    E9300H - Keysight Technologies

    Measure the average power of all modulation formats Wide dynamic range power measurements from -50 dBm to +30 dBm Frequency range 10 MHz to 18 GHzLow SWR for reducing mismatch uncertainty Calibration factors, linearity and temperature compensation data stored in EEPROM Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters

  • sbRIO-9211, Non-Enclosed, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module

    780877-01 - NI

    Non-Enclosed, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The sbRIO‑9211 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO‑9211 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.

  • NI-9263, 100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module

    783740-01 - NI

    100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module - The NI‑9263 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST‑traceable calibration. The NI‑9263 module includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.

  • NI-9263, 100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module

    779012-01 - NI

    100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module - The NI‑9263 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST‑traceable calibration. The NI‑9263 module includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.

  • Thermometers

    PCE Instruments

    At PCE you will find both a contact and non-contact thermometer for measuring and recording temperature. There is a thermometer to measure different temperature ranges between -200 and 1767ºC / -328 ... 3212ºF. Measurement of temperature is done in many different sectors. We also offer a thermometer that can indicate temperature in ºC, K (Kelvin) and ºF, as well as another that is water resistant.A wide range of thermal elements and type-K sensors are available for the thermometer. ISO calibration certificates, which include a laboratory calibration, can be ordered for most models in our thermometer range. Thermometers are instruments we use to measure the temperature of people or things.The most used and known thermometers are mercury thermometers used to measure peoples temperature and consisting of a graduated glass capillary and a pool of mercury in one end, but there are many types of thermometers such as digital thermometers that we have introduced which take temperature measurements on contact with an object these are suitable for any sector of industry. We even have infrared or laser thermometer to take measurements at distance, without contact.

  • Direct Reading Attenuator

    DAXE - Elmika

    DAXE Millimeter-Wave Direct Reading Attenuator is a measurement instrument for signal level setting or loss measurements in waveguide networks. It also can be used for calibration of other attenuation measurement instruments. Direct Reading Attenuators have rotary-vane design. The value of attenuation is determined by rotation angle of resistive film with respect to the waveguide channel. Attenuation value does not depend on of frequency.The Attenuators are provided in waveguide bands between 18 GHz and 225 GHz.

  • Optical Power Meter & VFL

    X0563 - Shinho Company

    Optical power meter X-0563 combines the handheld optical power meter and the visual fault locator(VFL) functions in one unit. It can be used for the absolute power measurement and relative measurement of the link loss in dB. Its compact size, friendly operation interface, broad power measurement range, high precision and brand-new user automatic calibration function and high performance in application makes it an ideal tool for optical fiber network.

  • Speed Switch

    LRB1000/LRB2000 - Electro-Sensors, Inc.

    Features• Works with remote/external pulse frequency output sensor (NPN, PNP)• Over- or under-speed 1-1,000 rpm• 1 SPDT relay output (LRB1000) or 2 SPDT relay outputs (LRB2000)• Visual setpoint adjustment with digital accuracy• Dial-in calibration does not require power• Built-in start delay• DIN rail mounting simplifies installation• 115, 230 VAC (50-60 Hz) and 12, 24 VDC power options

  • Web Sensor with PoE

    T3610 - COMET SYSTEM, s.r.o.

    PoE Web Sensor with built-in relative humidity and temperature sensors. High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Dual line LCD is an advantage. Power over Ethernet feature according IEEE 802.3af is supported. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.

  • Air Pollution Multigas Calibrator

    APMC-370 - HORIBA, Ltd.

    Dilution of gases with high accuracy and precision requires high quality MFC’s, especially for high dilution ratios and ranges. Consequently HORIBA’s APMC-370 is equipped with digital MFC’s. These MFC’s are factory calibrated, optional also with a special Polynomial Calibration. HORIBA Europe‘s APMC-370 is designed to calibrate gas analyzers manually, remotely controlled or automatically. It is installed in air pollution monitoring stations for quality assurance in the laboratory and also in the production of gas analyzers.

  • Software

    ELEMENTS - ELTRA GmbH

    The comprehensive Windows-based ELEMENTS software is an essential part of all ELEMENTRAC generation elemental analyzers. A central window (analysis and results) is the starting point from which all functionalities required for the daily routine are easily accessible. From here it is possible to group and export analyzed samples, or register and analyze new ones. The user may call up various subordinate functionalities like application settings, calibration, diagnosis, or status.

  • 1-Port 14 GHz Analyzer

    R140 - Copper Mountain Technologies

    R140 Vector Network Analyzer (cable and antenna analyzer) delivers lab grade performance in a handheld device. This patented (US Patent 9,291,657) analyzer can be connected directly to the antenna or other DUT without the need for a test cable, eliminating measurement uncertainties inherent to cables. Resulting in highly dependable performance and calibration stability. The 1-port VNA comes with all the features engineers have come to expect included standard in our software.

  • 1-Port 18 GHz Analyzer

    R180 - Copper Mountain Technologies

    R180 Vector Network Analyzer (cable and antenna analyzer) delivers lab grade performance in a handheld device. This patented (US Patent 9,291,657) analyzer can be connected directly to the antenna or other DUT without the need for a test cable, eliminating measurement uncertainties inherent to cables. Resulting in highly dependable performance and calibration stability. The 1-port VNA comes with all the features engineers have come to expect included standard in our software.

Get Help