Calibration
maintains accuracy of test asset by correcting out of specification conditions.
See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
product
Handheld Water Quality Meters
LAQUA EC210
- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Automatic / manual temperature compensation and temperature calibration function- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- °C & °F ...show more -
product
PXI-6232, 16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Multifunction I/O Module
779618-01
16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6232 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, sourcing digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measuremen...show more -
product
Spectrum Analysis For E5081A Up To 44 GHz
S960907B
The Keysight S960907B spectrum analyzer (SA) software application adds high-performance microwave spectrum analysis capabilities to the Keysight ENA-X up to 44 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Conduct simultaneous spectrum measurements using test and reference receivers. For efficient measurements of spurious signals emanating from mixers and frequency converters, combine t...show more -
product
PAT and Installation Verification Unit
PowerCheck 1557
The PowerCheck 1557 is a comprehensive PAT and installation verification checkbox. It carries out ongoing performance checks to ensure accurate measurement between calibration intervals. Fully tests Earth Continuity, Insulation Resistance, RCD Trip Time, RCD Trip Current, Loop, PE Conductor Current, Touch Current and Flash tests.
-
product
Toxic Gas Sensor
Model 100
Teledyne Gas & Flame Detection
Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level o...show more -
product
3-in-1 OSL Mechanical Calibration Kit, DC To 50 GHz, 2.4 Mm (m)
85564A
The 85564A 3-in-1 mechanical calibration standard combines an open, short and load standard in a compact unit. The product is small, easy to handle, and lightweight. All standards in the 85564A are male 2.4 mm.
-
product
Waterproof and Dustproof Portable pH Meter
CyberScan pH 300
Multi-Point Push-button Calibration (up to 5/6 points) with Auto-Buffer Recognition - choice of USA, NIST or DIN buffer standards for quick calibration with no calibration mistakes
-
product
Automated Test Equipment
Smart, swappable fixtures and flexible test bedsMulti-site setups, including multi-threadingLong-wire, short wire, and wirelessBed-of-nails for in-circuit testing (ICT)RF, high-speed digital, and thermal designsSolidWorks design expertise and global manufacturing (e.g., US, Mexico, China)Multiple options for mass interconnects (VPC, MAC Panel) and harnessesBuilt-in self-test (BIST) fixtures and calibration tools
-
product
Infrared Gas Detector
iTrans2
Teledyne Gas & Flame Detection
The iTrans2 infrared gas detector employs an intelligent electronics platform to provide one or two points of detection from a single head for maximum flexibility, superior performance and lower installation costs. With the optional HART Communication Protocol, the iTrans2 offers remote diagnostics, set-up or calibration by superimposing a high-frequency current across the industry standard 4-20mA analog line.
-
product
Hydrophone
RESON TC4013
The TC4013 offers a usable frequency range of 1Hz to 170kHz and a high sensitivity relative to its size. It further-more provides uniform omnidirectional sensitivities in both horizontal and vertical planes up to high frequencies.The TC4013 is an excellent transducer for making absolute sound measurements and calibrations within a broad frequency range. It can also be applied as an omnidirectional reference projector.The overall characteristics makes TC4013 extremely applicable for laboratory as well as industrial uses.
-
product
Testwave Calibration
Testwave® LLC calibrates electronic, physical, & dimensional test equipment. Our Sparks facility includes a state-of-the-art temperature controlled calibration laboratory, which holds the temperature to within +/- 0.5°C. We send you recall notices before your equipment calibration expires, and if we don’t hear from you, we will call, to make sure you stay in compliance with your calibration requirements. Calibrations are performed at your facility, or at our Sparks Nevada laboratory.
-
product
10 MHz To 54 GHz LAN Wide Dynamic Range Peak And Average Power Sensor
L2066XA
Accurately measure any modulated signal with the Keysight Technologies, Inc. U/L2050/60 X-Series wide dynamic range power sensors. The USB/LAN connectivity models come with a wide dynamic range, covering -70 to +26 dBm. This sensor offers very accurate and repeatable power measurements for any modulated signal and comes with a super-fast measurement speed of 50,000 readings/sec, which enables higher manufacturing throughput. Users can also save time and reduce measurement uncertainty with the in...show more -
product
Digital Pressure Gauge
Precision digital pressure gauges are suitable for stationary and also mobile measurement and display of pressures. In addition, a digital pressure indicator can be used as a pressure reference and enables the easy testing, adjustment and calibration of other pressure measuring equipment directly on site. Through efficient measuring cells with electronic linearisation of the characteristic curve, a high accuracy is achieved.
-
product
Chemical Analysis and Corrosion Testing
Performing chemical analysis of metal alloys including both ferrous and non-ferrous alloys.Chemical analysis involves determining the chemical constituents of metals and related materials.An industry leader and co-operating laboratory for qualifying Calibration Standards for Chemical Analysis.Our chemical laboratory processes include Spectroscopy – Optical Emission Inductively Coupled Plasma, gas analysers, wet chemical, Intercrystalline/ Intergranular Corrosion (including G28, G48 etc).
-
product
Structural Test ICP® Accelerometers
Conventional structural test data systems use few to several hundred sensors. Cables bundles can be complex and confusing resulting in setup errors. Sensors with TEDS (Transducer Electronic Data Sheet) allow for an internal sensor digital chip to store sensor information. This information contains descriptive identifiers that when connected to a TEDS compatible signal conditioner or data system, reads the descriptive information and automatically aligns the data system. Human error is minimi...show more -
product
7-Meter Laser Head Cable
10882B
The 10882B 7-meter Laser Head Cable is used to connect the 5519A/B Laser Head to the E1735A USB Axis Module for the 5530 Laser Calibration System.
-
product
Precision AC/DC Active Current Shunt
2575A
A versatile, powerful calibration tool, the 2575A Precision AC-DC Active Current Shunt measures both AC/DC current and works as a standard for low-level resistance calibration requirements.
-
product
Extractometer
Dynatest
*Extractometer used to measure and check the strength of fixing parts*Test carried out with a four-arm wheel or (and) the hydraulic pump with crank*Results on a pointer/digital indicator with peak value*Lightweight and easy to handle*Simple and quick setting up*Appropriate for on site testing*Packaged in a transport case (with a set of optional accessories)*Revolution counter for the crank*Delivered with a calibration results and the copy of the calibration report for the reference standard sensor
-
product
16-Channel RTD Signal Conditioning Card
ProDAQ 5821
The ProDAQ 5821 series of Signal Conditioning Cards is designed to interface with a variety of sensors, principally RTDs, Thermistors, Cryogenic Diodes and Voltage type sensors. Each version of the 5821 provides the capability of precise 4-wire measurement. In order to achieve this, a precise 500μA constant current source is provided per channel. The current source can be disabled on a per channel basis and is monitored to ensure that current is flowing. The value of the output current is stored...show more -
product
3-Lambda Power Meter
3λ-PM
•Simultaneous wavelength detection and calibration.•B / E / G – PON 3 wavelength power meter and insertion loss tester (1310 / 1490 / 1550 nm)•Simultaneous measurement of 3-wavelength PON signals•Automatic wavelength detection to save time and cost•Rugged, shock and water-proof for field use•Compact, lightweight and cost-effective•Quick and easy to operate
-
product
Thermometer Hygrometer
H3531-2
Sensor H3531 is designed for online monitoring of temperature, relative humidity of air without aggressive substances. Three binary inputs to detection of two-states signals are the advantage. Other devices are controlled by two relay outputs.High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
product
Wide Range Ohmmeter
PAS-853B
- Wide Resistance Measurement Range from 0.01 ohm to 9.99x1012 ohms- Nominal Full Range Tolerance Averages <±5%- Fully Automatic Resistance Range, Test Voltage and Electrification Period Control- Automatic or Continuous Electrification ControlRugged High Performance 80 inches (200cm) Test Leads Included- Powered by one long lasting 9V Alkaline Battery- Large, Easy to Read LCD Display- Meets requirements of ESD Association Standards for material and audit resistance measurement requirements- Certificate of Calibration Traceable to NIST included
-
product
1-Port 18 GHz Analyzer
R180
R180 Vector Network Analyzer (cable and antenna analyzer) delivers lab grade performance in a handheld device. This patented (US Patent 9,291,657) analyzer can be connected directly to the antenna or other DUT without the need for a test cable, eliminating measurement uncertainties inherent to cables. Resulting in highly dependable performance and calibration stability. The 1-port VNA comes with all the features engineers have come to expect included standard in our software.
-
product
ACCUplace Macro Calibration Standard
AP-M Series
With both X & Y axis metric scales, these dual axis targets are ideal for calibrating optical magnification in microscopes, linear distance, stage motion and squareness. In addition, with the larger area calibration scale, the calibration of low power optical systems over the longer distances can be easily carried out. The AP-M is offered on two standard materials; Glass (CG) and Opal (OP).
-
product
RFID Sensor Datenlogger (HF)
TELID®300
TELID® sensor data loggers are ideal for complex monitoring of quality assurance and maintenance, or while transporting foods, plants, pharmaceuticals or medical products. Temperature, humidity, pressure or shock-sensitive products can be monitored and traced, for example, during worldwide transportation. microsensys offers calibration services for the TELID®311, 311.ac and 314.ac. We carry out a factory (one- to three-point) calibration according to your temperature specifications, which are based on controlled operations and continuous monitoring, or ISO (one- to more point) calibration for temperature according to DAkkS specifications.
-
product
sbRIO-9215, Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
781029-01
Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9215 performs differential analog input. The sbRIO‑9215 contains NIST‑traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
product
Services
Maintenance and Support ServicesCare agreements for calibration, repair, maintenance and project services, extended warranties and training services
-
product
3.5mm Short Open Load Thru 4-in-1 Analyzer Calibration Kit
Fairview Microwave’s portable calibration kits consist of two models, both with a compact, lightweight, 4-in-1 design package. These short-open-load-through (SOLT) calibration kits feature precision 3.5mm connectors, have a 26.5 GHz calibration capability, gold plated short-open-load-thru and include a handy lanyard. These SOLT calibration kits have a phase deviation of +/-2 degrees maximum and return loss of 30 dB minimum and feature an impedance level of 50 Ohms nominal. They are ideal for telecommunications, military electronics, automotive, medical, aerospace and consumer electronics industries.
-
product
PD Calibrator
PDCAL has excellent pulse-with stability; scale calibration factors are permanently stored inside its flash memory. Thanks to on board photo coupler PDCAL output pulse can be synchronized with the actual line frequency through external surrounding electrical light source systems.
-
product
Phasor Measurement Unit Calibration System
6135A/PMUCAL
The 6135A/PMUCAL system is the only fully automated and traceable PMU calibration system available today. It fully complies to the IEEE C37.118.1™-2011 and section 7 of IEEE C37.242:2013 standards for PMU operation and verification.