Showing results: 451 - 465 of 1905 items found.
-
840A -
TEGAM Inc.
Used by calibration technicians or manufacturing engineers to perform field calibrations on K-J-T thermocouple thermometers. The single input/output meter doubles as a K-J-T thermometer.
-
N2002A -
Keysight Technologies
The N2002A noise source test set is a low cost, stand-alone instrument that, as part of a calibration system, enables fast, repeatable calibrations with minimal levels of uncertainty.
-
WIKA Alexander Wiegand SE & Co. KG
Hand-helds are portable calibration instruments for mobile use for the accurate measurement and recording of temperature profiles. For the instruments there are various designs of thermometers available. Through this, hand-helds are particularly suitable as test instruments for a large variety of applications in the widest range of industries. Data recorded in the hand-held can be evaluated via PC software, some instruments document calibrations in the internal memory, which can later be read on a PC. Optionally, a calibration certificate can be generated with our calibration software WIKA-Cal.
-
Mensor Corp.
Hand-helds are portable calibration instruments for mobile use for the accurate measurement and recording of temperature profiles. For the instruments there are various designs of thermometers available. Through this, hand-helds are particularly suitable as test instruments for a large variety of applications in the widest range of industries. Data recorded in the hand-held can be evaluated via PC software. Some instruments document calibrations in the internal memory, which can later be read on a PC. Optionally, a calibration certificate can be generated with our calibration software WIKA-CAL.
-
M2000/M2001 -
Martel Calibrators
The Lab Calibrator combines the power and features of a voltage/current calibrator, with the addition of thermocouple, RTD, and pressure calibration, for a single laboratory calibration instrument unmatched in versatility, performance, and value.
-
2575A -
Valhalla Scientific Inc.
A versatile, powerful calibration tool, the 2575A Precision AC-DC Active Current Shunt measures both AC/DC current and works as a standard for low-level resistance calibration requirements.
-
IEC61000 -
Newtons4th Ltd
N4L are the only IEC61000 EMC test system manufacturer in the world* with an on site UKAS ISO17025 calibration laboratory offering accreditation to IEC61000-3-2, IEC61000-3-3, IEC61000-4-7 and IEC61000-4-15. Calibration and trace-ability are a vital aspect of any EMC test solution and the coverage provided through N4L’s UKAS Laboratory is comprehensive. N4L’s IEC61000-4-15 calibration procedure is particularly noteworthy as it covers the entire test protocol detailed in Annex C of IEC61000-4-15. It is commonplace for specific parameters within IEC61000-4-15 (d parameters are frequently omitted from calibration procedures) to remain untested during typical flicker calibration due to the difficulty in providing trace-ability for such measurements. All tests within the test protocol of Annex C are included within the scope of accreditation and calibration procedures at N4L.
-
-
CHINO
Standard thermocouples for calibration of thermocouples.
-
-
W-C-7312 -
James Instruments Inc.
It is recommended that calibration of the test hammers be checked regularly usually after about 2000 strokes.The James Calibration Anvil (W-C-7312) has been designed for just that purpose.
-
Mensor Corp.
Hand-helds are portable calibration instruments for mobile use for the accurate measurement and recording of pressure profiles. There are interchangeable pressure sensors with measuring ranges of up to 8,000 bar available for the instruments. Through this, hand-helds are particularly suitable as test instruments for a large variety of applications in the widest range of industries. Data recorded in the hand-held can be evaluated via PC software. Some instruments document calibrations in the internal memory, which can later be read on a PC. Optionally, a calibration certificate can be generated with our calibration software WIKA-CAL.
-
WIKA Alexander Wiegand SE & Co. KG
Hand-helds are portable calibration instruments for mobile use for the accurate measurement and recording of pressure profiles. There are interchangeable pressure sensors with measuring ranges of up to 8,000 bar available for the instruments. Through this, hand-helds are particularly suitable as test instruments for a large variety of applications in the widest range of industries. Data recorded in the hand-held can be evaluated via PC software. Some instruments document calibrations in the internal memory, which can later be read on a PC. Optionally, a calibration certificate can be generated with our calibration software WIKA-CAL.
-
metrology equipment services, LLC
We have highly trained engineers to provide In-house repair and calibration services. Service Blanket Accounts are offered to customers with multiple systems. Loaner systems provided at no cost during system repairs and calibration. 3-5 business day turnaround guarantee on equipment repairs. All repairs and calibrations are covered under a 90-Day warranty.
-
M5180 -
Copper Mountain Technologies
VNAs and ACMs are delivered with factory calibration certificates containing no data. The add-on option for ISO17025/Z540-1 Accredited, Traceable Calibration Certificate and Uncertainties is available and needs to be specified at time of order.