Filter Results By:

Products

Applications

Manufacturers

Calibration

maintains accuracy of test asset by correcting out of specification conditions.

See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References


Showing results: 1786 - 1800 of 1906 items found.

  • NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    783863-01 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9217, 4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    779592-01 - NI

    4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9217 is a resistance temperature detector (RTD) input module. You can configure the NI‑9217 for two sample rate modes: high sample rate or high resolution. The NI‑9217 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9217 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module

    783864-01 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    783863-02 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • Power Meters and Calibration Cells

    Sciencetech, Inc.

    The Solar Reference Cell consist of a 20 x 20 mm monocrystalline silicon Photovoltaic Cell encased in a 92 x 70 x 16 mm metal enclosure with a protective quartz window and a temperature sensor. The temperature sensor is a 100 ohm platinum Resistance Temperature Detector (RTD).The Solar Reference Cells come with a Certificate of Calibration and compatible set of connecting cables. The following parameters of the reference cell are certified: Isc, Imax, Voc, Vmax, Pmax, Area, Fill Factor and Efficiency. The certification is accredited by NIST to the ISO-17025 standard and is traceable both to the National Renewable Energy Laboratory (NREL), and to the International System of Units (SI). A compatible cable set is also supplied with each Solar Reference Cell.

  • Flexible Rope-Type Current Probe

    RCT1A and RCT5A - Powertek LLC

    These probes have great bandwidth ensuring accurate measurement even with harmonically distorted wave shapes. For all RCT1A/RCT models, a NIST, NAVLAP, NPL (UKAS) factory traceable calibration certificate and certificate of conformance is supplied. UL/CSA approved materials are used throughout. Three phase and single phase flexible AC current sensors (rope sensors) are available for fast installation in confined spaces, eliminating the need for Electrical Supply Shutdown. Available outputs are 1A @ 2.5VA and 5A @ 0.5VA, this means long cable lengths from current sensor to signal conditioner allow these low VA ratings to be used, even when feeder cable to energy meter distances are large (up to 98 feet / 30 meters)

  • Image Analysis & Stage Micrometers

    Applied Image, Inc.

    The APPLIED IMAGE series of Image Analysis and Stage micrometers are ideally suited for calibrating optical, imaging, video, and reticle-based measurement systems. Designed for ease of use and manufactured for durability, the SM Series has both English and Metric scales in one or two axis configurations. Both types of micrometers come with NIST traceable calibration standards and are available on multiples substrates to perfectly fit your needs. The experience APPLIED IMAGE has in manufacturing precision imaged optical components makes us the trusted source for standards for magnification system microscopy and vision applications. Should you need to alter feature patterns, size, or substrate, fill out our Custom Optical Components and Standards form to start the conversation.

  • Engineering

    Lynred USA

    As a pioneer in infrared imaging solutions, our engineers have an unsurpassed level of proficiency in prototype design, customization and system integration. Our expertise is multifaceted ranging from advanced infrared sensor signal processing, calibration techniques, radiometry, optics, embedded software development, PC application software development, industrial and mechanical design and production tooling. Our goal is your successful project; one that utilizes the correct components and is completed on time and within budget. This is accomplished through our Concept to Solution approach which allows for the use of technically advanced components, group collaboration, quick responses and final products tested to spec. Whatever level of integration you choose and support you need, know our engineering team is there to assist.

  • Personal Noise Dosimeter with USB Interface

    Extech SL400 - Extech Instruments Corporation

    Sound level monitoring is essential to determine what protective measures are required for employees who are routinely exposed to loud noise. Perform noise surveys in compliance with OSHA, MSHA, DOD, ACGIH, and ISO standards with the Extech SL400 dosimeter. An SL400 noise accumulation survey can determine total sound exposure over an 8-hour period. This compact, lightweight dosimeter can also serve as a sound level meter, logging up to 999,999 readings with sampling times between 1 second and 24 hours. An optional 94 dB calibrator allows you to perform before-and-after calibration checks, per ANSI standards. The SL400 comes with PC software to control setup and retrieve stored events or analyze real-time measurements.

  • Static Load Cells

    2530 Series - Instron

    2530 Series load cells with capacities of 5 N to 100 N are for use with 3300 and 5900 testing systems. 2530 Series Load cells with capacities of 500 N to 100 kN are for use with 3300 testing systems.  The design, manufacture, and performance verification is conducted with materials testing applications in mind. Automatic transducer recognition and electrical calibration makes them easy to use. The load cells incorporate overload protection and can withstand loads up to 150% of their force capacity without damage and 300% without mechanical failure. The load cells allow the user to zero out the tare weight of a grip or fixture that weighs up to 10% or 40% of the force capacity, depending on the model, while still maintaining the full specified accuracy.

  • ExStik® 3-in-1 Chlorine, pH, Temperature Kit

    Extech EX800 - Extech Instruments Corporation

    The Extech EX800 ExStik 3-In-1 Kit includes the CL200 meter and pH electrode, reagent tablets (50 tests), four plastic cups, a weighted stand, pH buffer pouches, four CR2032 batteries, 48 inch neck strap, carrying case, and user manual. The meter measures Total Chlorine, pH, and Temperature with interchangeable flat surface electrodes that are included. Flat surface electrodes work in liquids, semi-solids and solids. Built-in memory can store/recall up to 15 readings and save the last calibrated value. It has a large 3-1/2 digit (2000 count) digital display with a bargraph and an automatic electronic self-calibration function for Chlorine (1, 2, or 3 point buffer calibration for pH).

  • Surface Resistance System Kit

    PRS-801RM - Prostat Corporation

    - Perform Point-to-Point and Resistance to Ground Measurements from 0.01 Ω to 200 Teraohms- Accuracy of ±2% from 1.00 Ω to 9.99x1010Ω- Measures in accordance with ESD TR53, ANSI/ESD S4.1, ANSI/ESD S7.1, ANSI/ESD STM97.1 and others- Constant Test voltages 10V and 100V meeting ANSI/ESD S20.20- Operates using a Rechargeable Li-ion Battery Pack- Takes Approximately 8,000 Measurements on a Single Charge (480 hours typical)- Stores up to 999 Test Values Into Memory- Compatible with Prostat Connect 2.0 for Downloading into Excel®- Charging and Download via Standard Micro USB Cable- Includes 5lb Conductive Probes and Carrying Case- Certificate of Calibration Traceable to NIST included- 2-year Limited Warranty on Main Instrument

  • 1.533 Μm Frequency-Locked Laser

    Thorlabs, Inc.

    Thorlabs' LLD1530 Frequency-Locked Laser is a narrow linewidth, DFB-laser-diode-based, turnkey system with a vacuum emission wavelength of 1532.8323 nm and a high SMSR of at least 35 dB. The laser frequency is actively stabilized to a National Institute of Standards and Technology (NIST)-traceable molecular transition of acetylene and has an absolute accuracy at start-up that is better than ±25 MHz. The emission frequency immediately after start-up is then maintained with a ±25 MHz stability, providing an overall frequency accuracy of ±50 MHz. The LLD1530 is an accurate frequency reference designed to provide low-noise laser emission with excellent frequency stability, accuracy, and precision immediately at start-up. This source is ideal for use in demanding FTIR instrumentation, instrument calibration, gas sensing, and coherent telecommunications applications.

  • 3-Phase AC Voltage Transducer

    ENVIROMUX-PT3-600 - Network Technologies Inc

    Monitors and reports voltage of any 3 phase circuit. Remotely detect blown fuses or tripped circuit breakers. Three 600 VAC inputs, three 4-20 mA outputs. Inputs and outputs isolated from one another. Frequency: 50/60Hz. Maximum primary current: 600 volts. Accuracy: ±0.25% F.S. @60Hz. Output: 4-20 mA. "Zero" adjustment for accurate 0 VAC reading, and "Calibration" adjustment for frequency and voltage level. Powered by the ENVIROMUX-S420MA-24V. Regulatory approvals: UL, CUL, CE. Requires two ENVIROMUX-S420MA-24V to monitor three phases. Caution: installation should be performed by qualified electricians only. Make sure electrical service is disconnected before making any electrical connections.

  • Workstation For Acoustic & Vibration Engineering

    imc WAVE 2022 - imc Test & Measurement GmbH

    imc WAVE is a modular, powerful software platform for noise and vibration analysis (NVH analysis). From noise investigations in road tests to structural analyses on the test bench and vibration tests on machines: with different imc WAVE analyzers, you can evaluate a wide range of applications without having to be an expert yourself. In this way, you can also easily and reliably obtain standard-compliant analysis from the fields of noise and sound power analysis, structure analysis as well as the evaluation of the analysis of vibrations and of rotating machines. imc WAVE guides you step by step through the settings, from device configuration to calibration and measurement. In the end, you evaluate your data professionally and then receive a report that is ready to print. The modular software specializes in the following topics.

Get Help