Filter Results By:

Products

Applications

Manufacturers

Calibration

maintains accuracy of test asset by correcting out of specification conditions.

See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References


Showing results: 1771 - 1785 of 1904 items found.

  • Multiport Coaxial Switch, DC to 20 GHz, SP4T

    87104B - Keysight Technologies

    The Keysight 87104B multiport switch improves insertion loss repeatability and isolation, which is necessary for higher performance test systems. The repeatability and reliability of this switch is vital to ATS measurement accuracy and can cut the cost of ownership by reducing calibration cycles and increasing test system up time. The Keysight 87104B terminated multiport switch provides the long life and reliability required for automated test and measurement, signal monitoring, and routing applications. Highly repeatable switching capability is made possible through Keysight's rigorous design and tight manufacturing specifications. Low insertion loss repeatability reduces sources of random errors in the measurement path, which improves measurement accuracy.

  • Handheld Water Quality Meters

    LAQUA DO210 - HORIBA, Ltd.

    Measures dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation0.01 mg/L or 0.1% DO resolutionCompensates salinity, temperature, and atmospheric pressure Allows up to 2 calibration points using galvanic DO electrode°C & °F temperature readingsAuto log data; built-in memory can store up to 500 dataAuto stable, auto hold, and real-time measurement modesAuto shut-off (programmable: up to 30 minutes)Built-in electrode holder allows 2 electrodes to be attached Monochrome LCD with white LED backlight: 50 x 50 mmCasing is IP67 waterproof/dustproof, shock & scratch resistant, non-slipPowered by 2 x AA batteriesPackaged with galvanic electrode in carrying case3 years meter warranty

  • Multichannel Voltage Output D/A Converters

    Analog Devices Inc.

    Analog Devices offers an industry-leading family of multichannel voltage output D/A converters (DACs), covering 8-bit to 16-bit resolutions, from 2-channel up to 40-channel density, and serial SPI or I2C interfaces. This family of precision D/A converters are in demand for applications that require high channel density and a small form factor, such as optical communications, analog output modules, or LED displays. ADI’s multichannel voltage output D/A converters provide features such as the availability of multiple independent output spans, system calibration functions that allow user-programmable offset and gain, or D/A converter increment/decrement functionality, which reduces the need to add external precision gain stages and facilitates the use of this family of D/A converters.

  • 16-bit, 200KHz, 16SE/8DIFF Isolated AI, 4 12-bit AO, 8 Optically Isolated Dig. I/O, 24V, 24 TTL I/O

    APCI-3116-16 - TEAM SOLUTIONS, INC.

    The APCI-3116 is a 16-bit multifunction board for 3.3 V and 5 V PCI systems, with optical isolation up to 1000 V and a high throughput rate of 200 kHz. The PCI board has additional types of conversion: Sequence RAM, Auto Refresh, scan, timer or external event.Furthermore, the board has a PCI DMA, 2 watchdogs, 4 digital inputs and 4 digital outputs. Sensors, which allow to supply current signals instead of voltage signals, also can be acquired with the APCI-3116, as this board offers up to 16 current inputs. The board is protected against overvoltage and input filter and it is protected against high frequency emmission. With the free calibration tool you can do the fine adjustment on-site.

  • 16-bit, 200KHz, 8SE/4DIFF Isolated AI, 4 12-bit AO, 8 Optically Isolated Dig. I/O, 24V, 24 TTL I/O

    APCI-3116-8 - TEAM SOLUTIONS, INC.

    The APCI-3116 is a 16-bit multifunction board for 3.3 V and 5 V PCI systems, with optical isolation up to 1000 V and a high throughput rate of 200 kHz. The PCI board has additional types of conversion: Sequence RAM, Auto Refresh, scan, timer or external event.Furthermore, the board has a PCI DMA, 2 watchdogs, 4 digital inputs and 4 digital outputs. Sensors, which allow to supply current signals instead of voltage signals, also can be acquired with the APCI-3116, as this board offers up to 16 current inputs. The board is protected against overvoltage and input filter and it is protected against high frequency emmission. With the free calibration tool you can do the fine adjustment on-site.

  • 12-bit, 200KHz, 16SE/8DIFF Isolated AI, 4 12-bit AO, 8 Optically Isolated Dig. I/O, 24V, 24 TTL I/O

    APCI-3110-16 - TEAM SOLUTIONS, INC.

    The APCI-3110 is a 12-bit multifunction board for 3.3 V and 5 V PCI systems, with optical isolation up to 1000 V and a high throughput rate of 200 kHz. The PCI board has additional types of conversion: Sequence RAM, Auto Refresh, scan, timer or external event.Furthermore, the board has a PCI DMA, 2 watchdogs, 4 digital inputs and 4 digital outputs. Sensors, which allow to supply current signals instead of voltage signals, also can be acquired with the APCI-3110, as this board offers up to 16 current inputs. The board is protected against overvoltage and input filter and it is protected against high frequency emmission. With the free calibration tool you can do the fine adjustment on-site.

  • 12-bit, 200KHz, 8SE/4DIFF Isolated AI, 4 12-bit AO, 8 Optically Isolated Dig. I/O, 24V, 24 TTL I/O

    APCI-3110-8 - TEAM SOLUTIONS, INC.

    The APCI-3110 is a 12-bit multifunction board for 3.3 V and 5 V PCI systems, with optical isolation up to 1000 V and a high throughput rate of 200 kHz. The PCI board has additional types of conversion: Sequence RAM, Auto Refresh, scan, timer or external event.Furthermore, the board has a PCI DMA, 2 watchdogs, 4 digital inputs and 4 digital outputs. Sensors, which allow to supply current signals instead of voltage signals, also can be acquired with the APCI-3110, as this board offers up to 16 current inputs. The board is protected against overvoltage and input filter and it is protected against high frequency emmission. With the free calibration tool you can do the fine adjustment on-site.

  • Semiconductors

    Bird Technologies

    Bird RF Laboratory Sensors have been depended upon for decades to provide highly accurate power measurement of laboratory and semiconductor production processes. Ranging from the 4020 Series sensors capable of 3% accuracy and the more advanced 4027 Series sensors capable of 1% accuracy. These highly accurate sensors have also been integrated into turnkey calibration carts that integrate all the components required to measure, display and dissipate power from RF delivery systems. Even more sophisticated systems, the VIP and BDS have been developed to not only measure voltage and current but also the phase relationships between them to enable a higher degree of insight into modern, complex semiconductor processes.

  • Surface Roughness Tester

    MTR110 - Rhopoint Metrology Ltd

    The Surfmatic MTR110 is a pocket sized surface roughness measuring instrument ideally suited to rapid on-the-spot surface measurements. Conforms to ISO Class 3.Features• Back-light LCD• Dynamic Test Display: progress of cut-off length during testing• Li-ion rechargeable batteries• Protection slide on pick-up• Auto-off after 90 seconds• Pocket-size and economically priced• Both Ra and Rz parameters in one instrument• Features external calibration specimen• Large measuring range suitable for most materials• Piezo-electric pick-up stylus for external surfaces• Includes steel test piece• Includes charger unit• Measurements of shafts above 40mm diameter using the Vee groove in base

  • Eurostat Turnstiles

    Eurostat Group

    For companies who need to ensure that the operators cannot enter the EPA unless their wrist straps and footwear are compliant every day• The turnstiles comply with ANSI/ESD S20/20 specification and ISO standards record keeping requirements • Both ESD safe shoes are tested separately through measuring electrodes, installed in the contact mat.• This system tests operators quickly (≤ 3 sec) and automatically and generate reports for the ESD coordinator• Communication with a server for traceability (Operator ID, Time & Date, Test values etc…)• LCD screen showing real time measurement• Keypad• Hygrometry measurement• Choice of measuring ranges and system calibration directly with the software• HID Wiegand interface, compatible to any HID card format

  • NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module

    783864-02 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module

    785189-01 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    785186-01 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    783863-01 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9217, 4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    779592-01 - NI

    4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9217 is a resistance temperature detector (RTD) input module. You can configure the NI‑9217 for two sample rate modes: high sample rate or high resolution. The NI‑9217 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9217 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

Get Help