Filter Results By:

Products

Applications

Manufacturers

CISPR

Comité International Spécial des Perturbations Radioélectriques (Special international committee on radio interference).


Showing results: 31 - 39 of 39 items found.

  • EMC Test System

    MICRONIX

    An electric product might cause the malfunction to other electric appliances by discharging the emission noise from it, or is oppositely caused the malfuction by the emission noise from other electric appliances. The former is checked by the EMI test and the latter is checked by the EMS test. The international standard like the CISPR standard is provided so that such an accident should not happen, and the manufacturer must declare by themselves beforehand that their product meets the standard. The generic name of the EMI test (Electro-Magnetic Interference) of the emission measurement and the EMS test (Electro-Magnetic Susceptibility) of the immunity

  • H.V. Proximity Detector

    275 HP - Standard Electric Works Co., Ltd

    ● Protection class: IP65.● 8 voltage settings: 240Vac, 2kV, 6kV, 11kV, 22kV, 33kV, 132kV, and 275kV.● High bright LED visual indication.● Sound indication.● Easy-to-prove method.● Self-test selection.● Use 3 × 1.5V “C” batteries.● High impact nylon casing.● Non-contact work by proximity.● Compatible with most link sticks.● Lightweight, robust, & compact.● Suitable for indoor and outdoor use.● Detects low voltage on any systems.● Easy access to batteries.● No special parts needed.● Meets EN 61326-1 CISPR 11 EN 61000-4-2 EN 61000-4-3● United States Design Patent : US D474, 705 S● Special ranges are available upon request.

  • Non-Contact H.V. Detector

    381 HP - Standard Electric Works Co., Ltd

    ● Protection class : IP65.● 7 voltage settings : 120V, 4kV, 15kV, 25kV, 35kV, 46kV, 69kV● Bright LED visual indication● Vibration function● Frequency range : 40~70Hz● Audible indication● Easy-to-prove method● Power source: 9V alkaline battery ● Non-contact detection by proximity● Compatible with most hot sticks● Lightweight, robust & compact● Special ranges are available upon request● Flashlight function● Safety standard : EN 61326-1   CISPR 11● Operating temperature and humidity :      0°C ~ 40°C / 80% R.H. Max. ● Dimensions : 262(L) × 85(W) × 56(D)mm● Weight: Approx. 345g

  • Non-Contact H.V. Detector

    380 HP - Standard Electric Works Co., Ltd

    ● Protection class : IP65.● 7 voltage settings : 120V, 4kV, 15kV, 25kV, 35kV, 46kV, 69kV●  Bright LED visual indication●  Vibration function●  Frequency range: 40~70Hz●  Audible indication●  Easy-to-prove method●  Power source : 9V rechargeable battery● Can be charged with the automotive● Non-contact detection by proximity● Compatible with most hot sticks● Lightweight, robust & compact● Special ranges are available upon request● Flashlight function● Safety standard :  EN 61326-1   CISPR 11● Operating temperature and humidity : 0°C ~ 40°C / 80% R.H. Max. ● Dimensions: 262(L) × 85(W) × 56(D)mm● Weight: Approx. 330g

  • Non-Contact H.V. Detector

    375 HP - Standard Electric Works Co., Ltd

    ● Protection class : IP65.● 8 voltage settings : 240V, 2kV, 6kV, 11kV, 22kV, 33kV, 132kV, 275kV● Bright LED visual indication● Frequency range: 40~70Hz● Flashlight funcion●Wider angle for voltage detection(120°)●Audible indication● Easy-to-prove method● Self-test function● Power source : 1.5V "C" type battery × 3● High impact nylon casing● Non-contact work by proximity● Compatible with most hot sticks● Lightweight, robust & compact● Suitable for indoor and outdoor use● Easy access to batteries.● Special ranges are available upon request. ● The maximum detection range can be 500kV.● Meets EN 61326-1 CISPR 11 EN 61000-4-2 EN 61000-4-3 EN 61000-4-8

  • Non-Contact H.V. Detector

    300 HP - Standard Electric Works Co., Ltd

    ● Protection class : IP66.● 3 LED indicators in a circle for easier viewing in any directions (360° LED indication).● 8 voltage settings : 240V, 2kV, 6kV, 11kV, 22kV, 33kV, 132kV, 275kV.● High bright LED visual indication.● With the longer shelter to make the 3 LED indicators brighter under the sun.● Sound indication.● The maximum voltage setting can be 500kV .● Self-test function.● Power source : 1.5V "C" type battery × 3.● High impact nylon casing.● Non-contact work by proximity.● Compatible with most hot sticks.● Lightweight, robust & compact. ● Suitable for indoor and outdoor use.● Easy access to batteries.● Special ranges are available upon request. ● The maximum detection range can be 500kV.● Meets EN 61326-1 CISPR 11 EN 61000-4-2 EN 61000-4-3 EN 61000-4-8

  • Non-Contact H.V. Detector

    278 HP - Standard Electric Works Co., Ltd

    ● Protection class : IP65.● 3 LED indicators in a circle for easier viewing in any directions (360° LED indication).● 8 voltage settings : 240V, 2kV, 6kV, 11kV, 22kV, 33kV, 132kV, 275kV● Bright LED visual indication● Frequency range: 40~70Hz● Longer hood makes LED indicators more visible● Audible indication● Easy-to-prove method.● Self-test function● Power source : 1.5V "C" type battery × 3● High impact nylon casing.● Non-contact detection by proximity● Compatible with most hot sticks.● Lightweight, robust & compact.● Suitable for indoor and outdoor use.● Easy access to batteries.● Special ranges are available upon request. ● The maximum detection range can be 500kV.● Meets EN 61326-1 CISPR 11 EN 61000-4-2 EN 61000-4-3 EN 61000-4-8

  • EMC Test Equipment

    TDEMI eXtreme series - Gauss Instruments

    Highest measurement speed. Highest accuracy. Incredible dynamic. New operation modes. The novel product line TDEMI eXtreme (TDEMI X) is the latest and most advanced level of full digital measurement equipment for emission testing on the fast lane. It is based on the unrivaled and patented TDEMI® real-time technology of GAUSS INSTRUMENTS. It is easy and efficient in upgrading its frequency range by a various number of extensions which can be integrated into the instrument step by step. The frequency ranges are 1 GHz, 3 GHz, 6 GHz, 18 GHz, 26.5 GHz or 40 GHz respectively. A large variety of configuration possibilities makes the TDEMI X to the customized solution perfect fitting into your lab and to your application according to civil standards (e. g. CISPR, EN, FCC Part 15, ANSI C63.2, ANSI C63.4), military standards (e. g. MIL-461G, but also its previous versions and revisions) as well as avionic standards (e. g. DO-160). The frequency range of the TDEMI X instruments starts at 9 kHz in its standard configuration and can be extended down to 10 Hz by the option MIL/DO-UG or even down to DC by the available option OSC-UG as well. Like all other TDEMI measurement systems, the TDEMI X measurement systems can be remotely controlled and fully automated via Ethernet (TCP/IP) very easily.

  • Emissions Test System

    PC-114 - Com-Power Corporation

    Perform Radiated & Conducted EMI pre-compliance testing at your facility up to 1 GHz. Com-Power PC-114 EMI emissions test system is a ideal solution performing pre-compliance EMC testing from 9 kHz - 1 GHz.. It has essential equipment needed for radiated and conducted EMI emissions measurements. The system includes a spectrum analyzer, antennas, near field probes, a preamplifier, LISN and a non conductive antenna tripod. Pre-compliance testing in EMC is a commonly used term not easy to define. In general, it implies testing done prior to formal testing for legal compliance. Formal legal compliance is performed at a facility designed and equipped with test instrumentation that is fully compliant with the applicable EMC standards. Such facility and instrumentation is capital intensive and can be expensive even to rent and not easily available. Compliance testing is performed per exacting requirements of the Standards and other reference documents adhering to the test methods and last detail. In addition, the test facility may require to be accredited by an accreditation body such as NVLAP, A2LA. Often it is desirable to know prior to compliance testing at such facility, whether a product is close to compliance and also how close. Pre-compliance testing is specially useful for specifications such as FCC, Part 15, EN 55022 or EN 55011 (CISPR 22 or CISPR11). Pre-compliance testing usually means using the full compliance methods but making a few educated compromises in use of site or equipment to reduce costs and testing time. Here are some benefits of pre-compliance testing.

Get Help