Showing results: 526 - 540 of 1709 items found.
-
PXI-C1553 -
Avionics Interface Technologies
Dual redundant, single, dual or quad stream configurationsSoftware selectable Transformer, Direct, and Bus Stub Coupling Modes - Concurrent Bus Controller, 31 Remote Terminals, & Bus monitor operation - Full error injection and detection - Multi-level triggers for capture and filtering - Ten high voltage (up from 30V) programmable DIO lines - IRIG-B time code encoder/decoder with free-wheeling mode - Time Synchronization to PXI 10MHz reference clock - Real-Time recording and physical bus replay - PXI trigger generation on 1553 bus events - Initiate BC, RT Simulation and BM Capture on PXI Triggers - Application interface supporting C, C++, C#, and .NET development - Device driver support: Windows, Linux, LabVIEW Real-Time (others on request) - Compatible with AIT’s Flight Simulyzer GUI Bus Analyzer Software
-
ReXdesk -
Influx Technology LTD
ReXdesk is our freely distributable software configuration and general-purpose software tool to work with ReXgen. It is designed to make CAN bus data logging easy.
-
SI-MOD66xx -
Sheldon Instruments
The SI-MOD66xx is a family of high resolution, multi function data acquisition and control modules that plug into any SI-CxDSP carrier processor card for the PCI bus.
-
VXI-5524A-3 -
ICS Electronics
* 3.3V power out instead of 5 V on Digital IO bus connector* All othe specifications same as listed above for the VXI-5524A board.
-
Asiczen Technologies
*Processor verification experience*Memory verification*Bus protocols and DMA verification*Expert in high speed controller verification*Physical layer (PHY) verification
-
Dewesoft d.o.o.
CAN interfaces and analyzers with easy to use CAN bus software with optional support for OBDII, J1939, XCP/CCP, CAN transmit, and reading of DBC files.
-
APXX429-x -
AIM GmbH
ARINC429 Test and Simulation bus interface with 4, 8, 16 or 32 Software programmable Tx/Rx channels plus up to 8 Discrete I/O’s.
-
Intrepid Control Systems
Interact with multiple networks, perform diagnostics, node/ECU simulation, data acquisition, automated testing, memory edit or calibration, and vehicle network bus monitoring.
-
Data Patterns Pvt. Ltd.
One of the world's leading architectures for high reliability electronics applications is the VME platform.The VME standard is managed by the VME bus International Trade Association, VITA.Embedded computing's most successful bus standard, VME bus, shows no signs of slowing down as it maintains it's position as the industry's de facto standard into the 21st century. The foundation of VME's longevity, namely it's steady rate of technological evolution combined with a commitment to backward compatibility with legacy hardware and software, has been the linchpin of it's popularity for nearly twenty-five years. Today, innovative enhancements to the standard, through the VME Standards Organisation (VSO), continue to improve VME bus' speed, performance and reliability, strengthening it's position as the ideal solution for today's increasingly stringent commercial, industrial and military system requirements (Source: VITA).Data Patterns has implemented a number of standard VME boards, driven by Customer needs for Processor and I/O requirements in this platform. Today, standard modules are available covering the needs of:
-
Analog Devices Inc.
The RS-485 specification meets the requirements for a truly multipoint communications network, and the standard specifies up to 32 drivers and 32 receivers on a single (2-wire) bus. Some RS-485 transceivers modify the input impedance to allow up to 8× more nodes to be connected to the same bus. Analog Devices offers a wide range of standard RS-485/RS-422 transceivers and iCoupler® isolated RS-485/RS-422 transceivers to suit many applications.
-
Analog Devices Inc.
Analog Devices offers a wide range of standard RS-485/RS-422 transceivers and iCoupler® isolated RS-485/RS-422 transceivers to suit many applications. The RS-485 specification meets the requirements for a truly multipoint communications network, and the standard specifies up to 32 drivers and 32 receivers on a single (2-wire) bus. Some RS-485 transceivers modify the input impedance to allow up to 8× more nodes to be connected to the same bus.
-
4112-5 -
VECTOR Electronics and Technology, Inc.
44 Gold plated edge contacts (22 each side) on 0.156"(3.96mm) centers.3-hole solder pads (0.28” x 0.080”) for interconnecting multiple components. Zig-Zag Bus Pattern on wiring side. Zig-Zag Bus Pattern provides access to voltage or ground at alternating hole positions.Continuous ground plane on component side with 0.085” etched clearance area around each hole. Row and column legends provided.
-
4112-4 -
VECTOR Electronics and Technology, Inc.
44 Gold plated edge contacts (22 each side) on 0.156"(3.96mm) centers. 3-hole solder pads (0.28” x 0.080”) for interconnecting multiple component leads. Zig-Zag Bus Pattern on wiring side.Zig-Zag Bus Pattern provides access to voltage or ground at alternating hole positions. Continuous ground plane on component side with 0.085” etched clearance area around each hole Row and column legends provided
-
Analog Devices Inc.
The RS-485 specification meets the requirements for a truly multipoint communications network, and the standard specifies up to 32 drivers and 32 receivers on a single (2-wire) bus. Some RS-485 transceivers modify the input impedance to allow up to 8× more nodes to be connected to the same bus. Analog Devices offers a wide range of standard RS-485/RS-422 transceivers and iCoupler® isolated RS-485/RS-422 transceivers to suit many applications.
-
ADock-4R -
AIM GmbH
The ADock-4R ANET Docking Station offer the capability to host up to 4 AIM ANET Ethernet based data bus interface devices in a single housing.