Filter Results By:

Products

Applications

Manufacturers

Showing results: 46 - 53 of 53 items found.

  • Photoelectrochemical Test System

    ModuLab XM - Ametek Scientific Instruments

    The system, based upon Solartron Analytical's world-leading experience in transfer function measurements, offers a high-quality measurement platform for characterizing a range of photoelectrochemical devices such as DSSC's, Perovskite cells, and Photoanodes," noted Professor Laurie Peter, world leading expert, University of Bath, UK. Professor Peter acted as scientific advisor during the development of the ModuLab PhotoEchem system and helped ensure the system met the requirements of the most demanding photovoltaic researchers in the market today.

  • Pendulum Impact Testing Machine

    Atico Export

    Direct indication of impact energy absorbed by specimen on large diameterAvailable with safety guard for the operatorInitial potential energy for Charpy is 300 Joules & for Izod is 170 Joules with a L.C. of 2 Joules (for Analogueodels) & resolution of 0.5 Joules (for Digital Model)Pendulum drop angle for Charpy is 140° & for Izod is 90°ASTM Impact Testing machine is also supplied, which conforms to E-23 ASTM standarAvailable with Gauges, Tongs, Sub-zero bath, Templates, U & V-Notch milling cutter (Optional)

  • Ampere Hour / Minute Meter

    IM2502 - Ajinkya Electronic Systems

    We offer IM2502 ampere hour / minute meter which is advance model of IM2501. Beside, from basic regular counting of ampere hour/minute or seconds, this one comes with totalizer. The totalizers is vital for all electroplating usages as this on manages the concentration of bath and also take care that over of additions of chemical. In a addition to the, features of IM2501 like preset setting and relay output are integrating in this one as well. Moreover, there is an additional counter for total AH (ampere hour) or AM (ampere minutes) flowing through the circuit.

  • HV Test System up to 20000 Volt

    LXinstruments GmbH

    Insulated test booth with large space for test items. 2 banana sockets for AC connection and 4 banana sockets for the DC connection of the DUTs. IC’s are tested in a long-term test. These are checked in an oil bath so that there are no air gaps to reduce the insulation. Maximum voltage 20 kV. Therefore, insulation tests must be carried out. Ensuring the standard-compliant test. For the safety of the operating personnel, the test cell is electrically locked while the high voltage measurement is active.

  • Solar Test Systems

    Ametek Scientific Instruments

    AMETEK Scientific Instruments manufactures a range of application specific XM (Xtreme Measurement) products focused on solar cell / photovoltaic research (developed in collaboration with Professor Laurie Peter of the University of Bath, UK). These products are so versatile that they can also be used for photoelectrochemical (PEC) water splitting applications; and make use of Solartron’s unique high performance XM specified potentiostats and frequency response analyzers to provide a full complement of techniques for research into energy, corrosion and analytical electrochemistry.

  • SC-1 Monitor

    CS-131 - HORIBA, Ltd.

    The CS-131 is a high-precision chemical concentration monitor designed for use with SC-1 solutions used in cleaning processes during semiconductor manufacturing. It offers a faster response speed in a more compact size than anything available to date. The CS-131 monitors the concentrations of the individual components of the SC-1 solutions (NH3/H2O2/H2O) which is widely used to remove particles and organic substances. The monitor has a number of outputs which can be utilized to keep the concentrations of the individual elements of the SC-1 solutions within the allowable ranges; this eliminates unnecessary replacement of chemicals potentially increasing bath life time and reducing chemical cost. In addition, a model with an integrated cooling unit is available, allowing accommodation of a broader range of sample temperatures.

  • Impact Testing Machine (Izod & Charpy)

    Atico Export

    Suitable for Charpy & Izod Impact tests on different materials. It is based on Pendulum principle.Rigid designs of instrument frame & other parts assure minimum energy absorption during fracture which results in improved test accuracies.The highly strained & wearing parts like support blocks & strikers are of special alloy steels duly heat treated.Direct indication of Impact energy absorbed by sample on large dial -Safety guard for the user is provided.Initial potential energy for Charpy is 300 Joules & for Izod is 170 Joules with a Least Count of 2 Joules (for Analogue models) & resolution of 0.5 Joules (for Digital Model).Drop Angle of Pendulum for Charpy is 140° & for Izod is 90°.ASTM Impact Testing machine is also provided, which conforms to E-23 ASTM standard.Gauges, Tongs, Sub-zero bath, Templates, U & V Notch milling cutters are available with it (Optional).

  • Autosampling Dissolution Tester with Built-In Sample Collector

    Vision AutoPlus & Vision AutoFill - Teledyne LABS

    The Vision® AutoPlus™ is a modern upgrade of the popular Hanson legacy AutoPlus™ autosampler. The Vision AutoPlus comes with a choice of 6 or 8 sampling channels, and DissoScan™ (1-bath) or Maximizer™ (up to 3 baths) configurations. Precision syringe pump mechanics, all-inert tubing and valves, and color touchscreen programming with up to 100 protocols are standard on each instrument.The Vision® AutoFill™ is a sample collector designed for seamless integration with the Vision AutoPlus to save space and to provide a 360 degree view for visual monitoring of the collection process.. Vision AutoFill accessories include choice of collection racks with 13 x 100 or 16 x 100 mm test tubes for UV-Vis, 12 x 32 mm vials for HPLC, sample trays with 12 x 32 mm vials for UPLC®, and more.