Showing results: 1696 - 1710 of 3938 items found.
-
M5400 -
Doble Engineering
The M5400 sends an excitation signal into the transformer and measures the returning signals. Comparing this response to baseline readings and results from similar units allows you to identify deviations and confirm internal mechanical problems.The M5400 reduces the uncertainty about apparatus condition by providing solid evidence of mechanical integrity or winding movement. Use it to help determine how a transformer is deteriorating, if it can go back in service after a fault or if it has been damaged during transit.
-
TLLA-2500 Pro -
MES Innovations
Detects and Alerts the user of almost ANY Telephone Wiretap (Tap), even from the Telephone Central Exchange (REMOBS), with the added ability of defeating common types of wiretaps.
-
MetaGeek, LLC
Get Tonic with your MetaGeek Enterprise Suite subscription
-
-
TSA4G1 -
Triarchy Technologies Corp.
Frequency Range: 1MHz to 4.15GHzFrequency Spans: 1MHz to 1000 MHzInput Level Range: -110 dBm to +30 dBmDimensions: 87.5mm x 23mm x 15mm (L x W x H)
-
TSA12G5 -
Triarchy Technologies Corp.
Frequency Range: Band1: 4.9GHz - 11.1GHz, Band2: 11.1GHz - 13.5GHzFrequency Spans: 1MHz to 1000 MHzInput Level Range: -95 dBm to +30 dBmDimensions: 87.5mm x 23mm x 15mm (L x W x H)
-
Analog Discovery -
Digilent Inc.
The USB-powered Analog Discovery lets you measure, visualize, analyze, record, and control mixed analog and digital signal circuits of all kinds. It's small enough to fit in your pocket, but powerful enough to replace a stack of lab equipment. Driven by the free original WaveForms software, the Analog Discovery digital oscilloscope lets you build and test analog and digital circuits in virtually any environment, in or out of the lab.
-
Model T100 -
Teledyne Advanced Pollution Instrumentation
The Model T100 uses the proven UV fluorescence principle, coupled with a state of the art user interface to provide easy, accurate, and dependable measurements of low level SO2.Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon 'kicker' and advanced optical design combine to prevent inaccuracies due to interferents.
-
Model N100 -
Teledyne Advanced Pollution Instrumentation
The Model N100 instrument uses the proven UV-fluorescence principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of low-level Sulfur Dioxide (SO2) gas.
-
A1 -
Micro-Sys ApS
HTML and CSS validate all pages within a website. Have link checker tool find broken links and broken redirects. Analyze file sizes, response codes, download times etc. of all pages. Optimize internal linking to focus link juice on pages you want indexed.
-
TOC-VWP -
Shimadzu Corp.
Phosphoric acid and the oxidant (persulfate) are added to the sample, which is heated under UV illumination to convert the TC in the sample to carbon dioxide. This carbon dioxide flows with the carrier gas via the dehumidifier into the NDIR sample cell. The area of the carbon dioxide peak signal is measured and this peak area is converted to TC concentration using a pre-prepared calibration curve.
-
ManageEngine
Analyze your WiFi networks and identify the reason behind spotty WiFi connectivity. Isolate and resolve the issue with your WiFi network using the diagnostic android app, ManageEngine WiFi Monitor Plus. Take stock of the performance of all the networks available at various points of your environment. Send the report to your manager directly from your android device - simple and easy.
-
LabSolutions TA -
Shimadzu Corp.
A new design and enhanced functions that can be used at a glance. Intuitive operations that allow seamlessly performing the sequence of processes from measurement to analysis, and the outputting of reports.
-
aiT WCET -
AbsInt Angewandte Informatik GmbH
In real-time systems, timely task completion is of the essence. Each real-time task has to be completed within a specified time frame in order to ensure that the system works correctly. In other words, it is essential that the WCET of each task is known.
-
Rapidox 2112 -
Cambridge Sensotec Ltd
The Rapidox 2112 Multiplex is housed in a 19″ rack mount unit and allows a programmed sequence of gas samples to be fed to a single gas analyser, thus saving money and space requirements.