Showing product results. 466 - 480 of 3936 products found.
-
Ultima ID RI-2004HV - Bacharach, Inc.
Neutronics Ultima ID RI-2004HV series utilizes non-dispersive infrared (NDIR) technology to determine the weight concentrations of R12, R134a, R22, hydrocarbons and air. Neutronics’ exclusive “Blend-ID” analytical software can also quickly and accurately indicate the presence of R410a blend refrigerant.
-
WinSoft Inc.
Occupied Bandwidth (OBW)Adjacent Channel Power (ACP)Channel Power (CHP)Complementary Cumulative Density Function (CCDF) Intermodulation (IMD)Spectrum Emission Mask (SEM) IQ (Waveform)Phase Noise
-
SA-2000 - BC Group International Inc.
The BC Biomedical SA2000 Features: AAMI Load Earth / Ground Lead Resistance Earth/Ground Leakage Current Chassis Leakage True RMS Measurements 85 to 265 VAC Operation.
-
SA-2000-INTL - BC Group International Inc.
The BC Biomedical SA-2000-INTL Base International Unit Model Features: Same as US BC Biomedical SA-2000 Model, but for users who need a power cord to meet their International Power Needs AAMI Load Earth/Ground Lead Resistance Earth/Ground Leakage Current Chassis Leakage True RMS Measurements 85 to 265 VAC Operation.
-
Keysight Technologies
Choose from Wide-open real-time analysis to low-cost essential measurementsAchieve deeper troubleshooting or one-button measurements with the broadest set of application-specific softwareEvolve as technology changes with post-purchase upgrades such as frequency, bandwidth, real-time, CPU and moreDrive consistent measurements across your organization, no matter which instruments you choose to use, with 100% code-compatibility from R&D to manufacturing
-
SpectraSERIES - Sound Technology Inc.
Scalable to accommodate every application and budget, a wide array of targeted add-ons now extend Spectra’s productivity to more applications than ever before and provides immediate acquisition & measurement – Spectra is ready to go out of the box, no programming required!
-
Daqarta
The four traces used different windowing and averaging options. They were saved to Juxt Array memory and displayed with no added offset or spacing, to allow direct comparison. The selected trace in the array is shown with full brightness, to indicate that the cursor readouts and labeled Fields refer to this trace only. The other traces have been dimmed with the highlight control. The Juxt Trace Label Field has been set to show the contents of the Field labeled "Average", which is "32TC" for the selected trace.
-
SA-S - EMC Test Design, LLC
RF Frequency Range: 1 Hz to 4.2 GHz. Low noise amplifier available above 500 KHz. Wide dynamic range: -151 dBm to +10 dBm. Resolution bandwidths (RBW) of 0.1 Hz to 250 KHz and 5 MHz. Includes a High Dynamic Range Measuring Receiver. 0.25 dB relative accuracy. 0 dBm to -125 dBm, 150 KHz to 1 GHz. 0 dBm to -115 dBm, 1 GHz to 4.4 GHz. Adjustable digital audio filters. Accurate AM and FM measurements
-
BB60C - Signal Hound
The BB60C streams 140 MB/sec of digitized RF to your PC utilizing USB 3.0, providing an instantaneous bandwidth of 27 MHz, and sweep speeds of 24 GHz/sec. The BB60C has significantly improved performance compared to the BB60A. The BB60C has improved spurious-free dynamic range (SFDR) by 20 dB, flattened the noise floor and band transitions by more than 8 dB, and extended operating temperatures from -40ºC to +65ºC (Option 1). The BB60C also adds new functionality in the form of configurable I/Q streaming bandwidths which will be retroactively available on the BB60A.
-
H45 Advance - Televés, S.A.
The H45 are a milestone in the design of spectrum analyzers. Professional spectrum analyser - - 2,5GHz The latest technology and the latest features in a comprehensive range take will never become obsolete since any meter can be upgraded to the coming technologies .DVB, DVB-T,DVB-C, DVB-S,DVB-S2, LTE simulator
-
FPL1000 - Rohde & Schwarz GmbH & Co. KG
In an RF lab, the R&S®FPL1000 is as indispensable as an oscilloscope or multimeter. It is a single measuring instrument for a variety of measurement tasks. It supports not only spectrum analysis, but also highly accurate power measurement with power sensors and analysis of analog and digitally modulated signals.
-
SPECMON Series - Tektronix, Inc.
Leading real time technologies help to troubleshoot the toughest transient interferences in the fieldUnique Swept DPX enables the customer to "Real-Time Scan" the whole 3/6.2/26.5 GHz frequency range for transient interference discoveryUp to 165 MHz ultra-wide real-time BW SFDR of 80 dBc over the entire acquisition bandwidth for "close-in" signal discovery, capture and real-time demodulationExceptional DPX Density Trigger/Trigger on This, Frequency Mask Trigger and other advanced triggering capabilities provide 100% probability of intercept for signals as short as 0.434 s in the frequency domain and 12 ns in the time domainSave hours of post-capture review time with optional advanced triggering capabilities such as Save-on-Trigger, which intelligently saves events of interest automatically
-
xDSL - Sparnex Instruments
The spectrum analysis capabilities make this tester the preferred tool of the equipment manufacturer and DSL development groups. They use the ICXACT to debug and improve the data throughput up to the limits imposed by the Physical Layer, while adhering to the recommendations as set by the national Spectrum Regulator and the international Telecommunication Bodies. Service Providers are using it to probe the quality of the service over the network.
-
-
Shanghai MCP Corp
Frequency range:0.15∼500MHz(SA5005/SA5006T) 0.15~1050MHz(SA5010/SA5011T).Amplitude range:-100~+13dBm.Tracking generator(SA5006/SA5011T).Output level range:-50~+1dBm(in 10dB steps and var.)