Showing results: 2791 - 2805 of 3743 items found.
-
MSOV204A -
Keysight Technologies
20 GHz analog bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.54 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Access the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
MSOV254A -
Keysight Technologies
25 GHz analog bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.73 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Access the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
778756-01 -
NI
100 MHz, 100 MS/s, 14-Bit PXI Oscilloscope—The PXI‑5122 high-resolution PXI oscilloscope has two channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth. The PXI‑5122 also features PXI synchronization and data streaming capabilities.
-
778756-02 -
NI
100 MHz, 100 MS/s, 14-Bit PXI Oscilloscope—The PXI‑5122 high-resolution PXI oscilloscope has two channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth. The PXI‑5122 also features PXI synchronization and data streaming capabilities.
-
778756-04 -
NI
100 MHz, 100 MS/s, 14-Bit PXI Oscilloscope—The PXI‑5122 high-resolution PXI oscilloscope has two channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth. The PXI‑5122 also features PXI synchronization and data streaming capabilities.
-
778758-01 -
NI
100 MHz Bandwidth, 100 MS/s, 14-Bit PCI Oscilloscope Device—The PCI‑5122 high-resolution oscilloscope device has two channels with greater than 75 dBc spurious‑free dynamic range (SFDR) and flexible settings for coupling, impedance, voltage range, and filtering. Oscilloscope devices also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth.
-
778758-03 -
NI
100 MHz Bandwidth, 100 MS/s, 14-Bit PCI Oscilloscope Device—The PCI‑5122 high-resolution oscilloscope device has two channels with greater than 75 dBc spurious‑free dynamic range (SFDR) and flexible settings for coupling, impedance, voltage range, and filtering. Oscilloscope devices also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth.
-
778758-02 -
NI
100 MHz Bandwidth, 100 MS/s, 14-Bit PCI Oscilloscope Device—The PCI‑5122 high-resolution oscilloscope device has two channels with greater than 75 dBc spurious‑free dynamic range (SFDR) and flexible settings for coupling, impedance, voltage range, and filtering. Oscilloscope devices also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth.
-
MSOV164A -
Keysight Technologies
16 GHz analog bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.32 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Access the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
MSOV134A -
Keysight Technologies
13 GHz analog bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.09 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Access the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
CS-8820 -
Wuxi Tianmu Instrument Technology Co., Ltd.
1. Infrared detector with low noise, high sensitivity and high stability. 2. The modular design of the whole machine improves the reliability of the instrument. 3. The electronic balance is automatically connected. 4, WINDOWS full Chinese operation interface, easy to operate, easy to master. 5. Dynamic display of various data and carbon in the analysis process. 6, measuring linear range is wide, and can be expanded. 7, high-frequency circuit design is reasonable, high-frequency furnace power is adjustable, suitable for different material sample analysis requirements. 8. The automatic cleaning device of the burner can reduce the influence of dust on the analysis results. 9. The burner heating device makes the conversion rate of sulfur tend to be consistent, which improves the stability of sulfur determination. 10, measuring linear range is wide, and can be expanded. 11. The software is fully functional, providing more than forty functions such as file help, system monitoring, channel selection, mathematical statistics, result correction, breakpoint correction, and system diagnosis.
-
FTX-ONE-CS/RS -
HORIBA, Ltd.
The FTX-ONE offers a 5Hz sampling rate and simultaneously measure the concentrations of multiple components including NH3, CH4, and CO2, from (engine) direct exhaust gas using the Fourier Transform Infrared (FTIR) method in combination with multivariate analysis algorithm.
-
Haas Laser Technologies, Inc.
The Haas Laser Technologies Laser Beam Analyzer System is a modular design. The system includes software, sensors, attenuation modules and filters which enable “real-time” laser beam measurement, analysis and monitoring of high power CW and pulsed lasers.
-
S3120 -
COMET SYSTEM, s.r.o.
Data logger is designed for record of temperature and humidity. Values are stored to a non volatile electronic memory. Data transfer to the personal computer for further analysis is performed via USB, RS232, GSM or Ethernet interface by means of a proper communication adapter.
-
S3120E -
COMET SYSTEM, s.r.o.
Data logger is designed for record of temperature and humidity. Values are stored to a non volatile electronic memory. Data transfer to the personal computer for further analysis is performed via USB, RS232, GSM or Ethernet interface by means of a proper communication adapter.