Filter Results By:

Products

Applications

Manufacturers

Analog

representation of a signal that varies over an infinite range of values.

See Also: Digital


Showing results: 2176 - 2190 of 2948 items found.

  • Secure Voice & Data Communications in EURO-ISDN

    ELCRODAT 6-2 - Rohde & Schwarz GmbH & Co. KG

    Rohde & Schwarz ELCRODAT products protect voice and data communications in digital and analog armed forces and government networks in all German and NATO security classifications.The ELCRODAT 6-2 is the first encryption unit approved for transmitting information classified as TOP SECRET that uses a public key method for key agreement. Together with the public key method, the noise generator in the encryption unit enables mutual authentication and key agreement. New session keys are generated in the encryption unit for each connection. The keys do not leave the units and are deleted after the session for maximum security.

  • PXI FlexRIO IF Transceiver

    NI

    The PXI FlexRIO IF Transceiver combines analog I/O and a user-programmable FPGA into a single, customizable instrument. The instrument enables direct RF acquisition up to 6 GHz. You can use the instrument in a dual-channel mode at 3.2 GS/s or in a single-channel interleaved mode at 6.4 GS/s. The PXI FlexRIO IF Transceiver uses FPGAs from Xilinx alongside LabVIEW and Vivado programming options for custom algorithm implementation and real-time signal processing. Using this instrument with NI-TClk, you can synchronize modules in one or more PXI chassis at up to picosecond‐level accuracy for high‐channel‐count applications.

  • PCI-5122, 100 MHz Bandwidth, 100 MS/s, 14-Bit PCI Oscilloscope Device

    778758-03 - NI

    100 MHz Bandwidth, 100 MS/s, 14-Bit PCI Oscilloscope Device—The PCI‑5122 high-resolution oscilloscope device has two channels with greater than 75 dBc spurious‑free dynamic range (SFDR) and flexible settings for coupling, impedance, voltage range, and filtering. Oscilloscope devices also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth.

  • PCI-5122, 100 MHz Bandwidth, 100 MS/s, 14-Bit PCI Oscilloscope Device

    778758-02 - NI

    100 MHz Bandwidth, 100 MS/s, 14-Bit PCI Oscilloscope Device—The PCI‑5122 high-resolution oscilloscope device has two channels with greater than 75 dBc spurious‑free dynamic range (SFDR) and flexible settings for coupling, impedance, voltage range, and filtering. Oscilloscope devices also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth.

  • sbRIO-9222, Non-Enclosed, ±10 V, 500 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    785479-01 - NI

    Non-Enclosed, ±10 V, 500 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9222 performs differential analog input. This module is well suited for applications such as ballistics, impact, and blast wave testing. The sbRIO‑9222 can sample at the maximum sample rate per channel while the module next to it samples at a much slower rate, which is ideal for mixed-measurement test systems. There are two connector options for the sbRIO‑9222: a 10‑position screw terminal or a 25‑pin D‑SUB connector.

  • NI-9351, 4-Channel C Series Functional Safety Module

    784446-01 - NI

    4-Channel C Series Functional Safety Module - The NI-9351 works with 24 V industrial logic levels to directly connect to various sensor types, including light curtains, emergency e-stop buttons, and final elements such as relays, contactors, and motor drives. The NI-9351 is an analog input and digital I/O Functional Safety Module capable of SIL 3 certification according to IEC 61508. You can use the Functional Safety Editor to program the safety logic solver, which resides in the module. The module features diagnostics for monitoring the status of hardware and the integrity of the connections.

  • NI-9206, ±10 V, 250 kS/s, 16-Bit, 32-Channel, 60 VDC Isolation C Series Voltage Input Module

    779526-01 - NI

    ±10 V, 250 kS/s, 16-Bit, 32-Channel, 60 VDC Isolation C Series Voltage Input Module - The NI‑9206 performs differential analog input with four programmable input ranges. The module provides up to 600 VDC (400 VDC in Europe) channel‑to‑earth ground isolation, making the module ideal for accurately monitoring large fuel cell and battery stacks. By referencing the module common (COM) to the middle of the NI‑9206 bank, you can measure 16 consecutive cells and remain within 10 V of the module COM.

  • PXI-5122, 100 MHz, 100 MS/s, 14-Bit PXI Oscilloscope

    778756-01 - NI

    100 MHz, 100 MS/s, 14-Bit PXI Oscilloscope—The PXI‑5122 high-resolution PXI oscilloscope has two channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth. The PXI‑5122 also features PXI synchronization and data streaming capabilities.

  • PXI-5122, 100 MHz, 100 MS/s, 14-Bit PXI Oscilloscope

    778756-02 - NI

    100 MHz, 100 MS/s, 14-Bit PXI Oscilloscope—The PXI‑5122 high-resolution PXI oscilloscope has two channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth. The PXI‑5122 also features PXI synchronization and data streaming capabilities.

  • PXI-5122, 100 MHz, 100 MS/s, 14-Bit PXI Oscilloscope

    778756-04 - NI

    100 MHz, 100 MS/s, 14-Bit PXI Oscilloscope—The PXI‑5122 high-resolution PXI oscilloscope has two channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth. The PXI‑5122 also features PXI synchronization and data streaming capabilities.

  • PCI-5122, 100 MHz Bandwidth, 100 MS/s, 14-Bit PCI Oscilloscope Device

    778758-01 - NI

    100 MHz Bandwidth, 100 MS/s, 14-Bit PCI Oscilloscope Device—The PCI‑5122 high-resolution oscilloscope device has two channels with greater than 75 dBc spurious‑free dynamic range (SFDR) and flexible settings for coupling, impedance, voltage range, and filtering. Oscilloscope devices also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth.

  • Keysight Dual/Quad 4x8 Reed Matrix for 34980A

    34933A - Keysight Technologies

    The Keysight 34933A module for the 34980A Multifunction Switch/Measure Unit gives you the most flexible connection path between your device under test and your test equipment, allowing different instruments to be connected to multiple points on your device under test at the same time. Dual 4x8, 8x8, or 4x16 2-wire configurations 64 2-wire or 128 1-wire cross-points High-speed reed relays Connections to the internal DMM Expandable via four 2-wire analog buses Relay counter ±150 V peak, .5 A switch, 1.5 A carry current

  • NI-5781 , 40 MHz Bandwidth, RF Adapter Module for FlexRIO

    781267-01 - NI

    The NI‑5781 is an analog dual-input, dual-output FlexRIO adapter module optimized for interfacing with baseband to RF upconverters and downconverters. When you pair the NI‑5781 with a PXI FPGA Module for FlexRIO, the resulting NI‑5781R is an FPGA-enabled reconfigurable I/O (RIO) baseband transceiver that you can use to implement custom RF modulation and demodulation, channel emulation, bit error rate testing, or spectral monitoring and jamming. Additionally, you can use the low latency and high throughput of FPGA‑based processing for ultra‑high‑speed control and inline processing applications.

  • Dual 2.0 Gsps. 12 Bit ADC FMC

    ADF-D2000 - Delphi Engineering Group, Inc

    This FPGA Mezzanine Card (FMC) converts two channels of up to 2.8GHz analog input bandwidth at 1.0, 1.6, 1.8, or 2.0 Gsps and 12-bit resolution.   Additionally, this FMC can be used in an interleaved mode to convert a single channel at 2.0, 3.2, 3.6, or 4.0 Gsps and 12-bit resolution.  Based on the VITA 57 specification, the ADF-D1600 enables direct coupling of unparalleled analog-digital conversion capability with the VME/VXS/AMC/VPX/PCI-E carrier board of your choice.  DEG engineers have designed this product and associated HDL firmware to work with both Altera and AMD FPGAs.

  • NI-9213, cDAQ-9171, and cRIO-9940 USB Temperature Measurement Bundle

    865682-01 - NI

    NI-9213, cDAQ-9171, and cRIO-9940 USB Temperature Measurement Bundle - The USB Temperature Measurement Bundle with NI-9213, cDAQ-9171, and cRIO-9940 includes the NI-9213 C Series Temperature Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the cRIO-9940 Backshell for strain relief and operator protection from high-voltage signals. The included NI-9213 provides noise immunity, a high common-mode voltage range, NIST-traceable calibration, differential analog inputs, and four channels. Additionally, the NI-9213 features anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements.

Get Help