Filter Results By:

Products

Applications

Manufacturers

Analog

representation of a signal that varies over an infinite range of values.

See Also: Digital


Showing results: 2776 - 2790 of 2941 items found.

  • Sound Level Meter/Datalogger

    Extech SDL600 - Extech Instruments Corporation

    The SDL600 records data on an SD card in Excel format. High accuracy ±1.4dB meets ANSI and IEC 61672-1 Type 2 standards. 30 to 130dB measurement range. Auto or Manual ranging. AC analog output for connection to an analyzer or recorder. Large backlit LCD display. Stores 99 readings manually and 20M readings via 2G SD card. Datalogger date/time stamps and stores readings on an SD card in Excel format for easy transfer to a PC. User programmable sampling rate from 1 to 3600 seconds. Featuring Min/Max, Data Hold, and Auto Power Off functions. Complete with 6 AA batteries, SD Card, wind screen, and hard carrying case.

  • Digital High Voltage Insulation Tester - Autoranging Insulation Measurements to 10MOhm

    Extech 380363 - Extech Instruments Corporation

    This Extech insulation tester measures up to 10GΩ with 250V, 500V and 1000V Test Voltages. Features include: Lo-Ohms for testing connections, analog bargraph for viewing trends, AC/DC Voltage measurement to 999V, manual data record/recall function (9 sets), and live circuit display warning and beeper. Can be used to test motor, transformer windings, instruments, and appliances, check for moisture in wire and cable assemblies, safely evaluate a new wiring installation, and check for carbon tracking in breakers, relays, and switches. Extech Insulation Testers offer high sensitivity to assure reliable monitoring of low resistance motor windings. Complete with carrying case, test leads, and 6 x AA batteries.

  • Laboratory EM current meter / water level and wave height meter

    JFE Advantech Co., Ltd.

    ACM2-RS and ACM3-RS are 2-D and 3-D electro-magnetic current meters for laboratory experiments. The models provide digital output, a high-speed sampling rate and insusceptibility to electro-magnetic noise. ACH-600RS is a highly sensitive capacitance water level meters. With the new system, a maximum of four different sensors can be connected to the compact interface unit, enabling simultaneous recording on a personal computer. Additionally, the system can provide analog output as well as necessary. While conventional water level and wave height meters cannot be used near velocity sensors, our instrument can be as near as 5 cm without increasing noise, due to its special isolated circuit. The result is an innovative system that is capable of achieving highly accurate data.

  • Digital Tank Test Kit

    4109 - M. C. Miller Company

    The voltmeter included in the kit, the “Model DPM” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers two ranges, ±2VDC and ±20VDC with a 20MΩ input impedance. Since the voltmeter is digital [in contrast to the meter in our analog tank test kit (Cat. # 4108)], both negative and positive voltages are displayed. `

  • PXIe-4340, PXI Displacement Input Module

    785068-01 - NI

    The PXI Displacement Input Module supports 4-, 5-, and 6-wire AC linear variable differential transformer (LVDT) and AC rotary variable differential transformer (RVDT) measurements. The module simultaneously samples each analog input and sets the excitation frequency and voltage for each channel independently. You can set different timing, triggering, and sampling modes for each channel independently. Diagnostic features include self-calibration, overcurrent detection, and open coil detection.The PXI Displacement Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • PXIe-4492, 204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module

    781490-01 - NI

    204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module - The PXIe‑4492 is designed for sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the module is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4492 delivers simultaneous sample on all channels. In addition, it includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gains, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.

  • cDAQ-9179, 14‑Slot, USB 3.0 CompactDAQ Chassis

    783597-01 - NI

    14‑Slot, USB 3.0 CompactDAQ Chassis - The cDAQ‑9179 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements with the higher performance data streaming of USB 3.0. It also controls the timing, synchronization, and data transfer between C Series I/O modules and an external host. You can use this chassis with a combination of C Series I/O modules to create a mix of analog I/O, digital I/O, and counter/timer measurements. The cDAQ‑9179 also has four 32‑bit general-purpose counters/timers. You can access these counters, as well as share clocks and triggers, through two built-in BNC connectors.

  • cDAQ-9132, 1.33 GHz Dual-Core Atom, 4-Slot, CompactDAQ Controller

    783338-01 - NI

    1.33 GHz Dual-Core Atom, 4-Slot, CompactDAQ Controller - The cDAQ‑9132 controls the timing, synchronization, and data transfer between C Series I/O modules and an integrated computer. It includes Intel Atom dual-core processing and 16 GB nonvolatile storage for data-logging and embedded monitoring. You can choose between running Windows or NI Linux® Real‑Time. The cDAQ‑9132 offers an array of standard connectivity and expansion options, including SD storage, USB, Ethernet, RS232 serial, and trigger input. You can combine the cDAQ‑9132 with up to four C Series I/O modules for a custom analog I/O, digital I/O, counter/timer, and controller area network (CAN) measurement and logging system.

  • cDAQ-9132, 1.33 GHz Dual-Core Atom, 4-Slot, CompactDAQ Controller

    783339-01 - NI

    1.33 GHz Dual-Core Atom, 4-Slot, CompactDAQ Controller - The cDAQ‑9132 controls the timing, synchronization, and data transfer between C Series I/O modules and an integrated computer. It includes Intel Atom dual-core processing and 16 GB nonvolatile storage for data-logging and embedded monitoring. You can choose between running Windows or NI Linux® Real‑Time. The cDAQ‑9132 offers an array of standard connectivity and expansion options, including SD storage, USB, Ethernet, RS232 serial, and trigger input. You can combine the cDAQ‑9132 with up to four C Series I/O modules for a custom analog I/O, digital I/O, counter/timer, and controller area network (CAN) measurement and logging system.

  • Digital Portable Panel Meters

    ST-2001 ACV - Standard Electric Works Co., Ltd

    ● Big-size LCD (112 x 59mm)● Backlight function.● Analog scale with Bar-graph for viewing. (100 bars)● 10000 counts (high resolution).● DCV Ranges: 99.99mV~999.9V (ST-2001 DCV). ● ACV Ranges: 99.99mV~800.0V (ST-2001 ACV). ● 5 manual ranges controlled by rotary switch.● Data Hold function● Low battery indication● 9V power supply● Best resolution of 0.01mV (10uV)● Precision meter for factory maintenance, field servicing and educational purposes.● With an optical USB to RS-232 data transmission cable. (DCV-R & ACV-R)● 2 optical LEDs are built-in for data transfer. (DCV-R & ACV-R)● Well isolated to contact. (DCV-R & ACV-R)● The software is included (Compact disc). (DCV-R & ACV-R)

  • Digital Portable Panel Meters

    ST-2001 DCV - Standard Electric Works Co., Ltd

    ● Big-size LCD (112 x 59mm)● Backlight function.● Analog scale with Bar-graph for viewing. (100 bars)● 10000 counts (high resolution).● DCV Ranges: 99.99mV~999.9V (ST-2001 DCV). ● ACV Ranges: 99.99mV~800.0V (ST-2001 ACV). ● 5 manual ranges controlled by rotary switch.● Data Hold function● Low battery indication● 9V power supply● Best resolution of 0.01mV (10uV)● Precision meter for factory maintenance, field servicing and educational purposes.● With an optical USB to RS-232 data transmission cable. (DCV-R & ACV-R)● 2 optical LEDs are built-in for data transfer. (DCV-R & ACV-R)● Well isolated to contact. (DCV-R & ACV-R)● The software is included (Compact disc). (DCV-R & ACV-R)

  • Test Benches

    Atec, Inc.

    Atec has made test equipment throughout all of its 65-year history. Test benches for aerospace and energy uses represent a significant segment of our experience. Atec has produced test benches involving hydraulics, mechanicals, electromechanicals, electronics, pneumatics, motors, and digital automation. Atec test benches have performed for challenging measurements, factory production, problem analysis and component overhaul scenarios. Today, complex test benches have capable data acquisition, control and communication systems integral in their electronics. Atec’s ADAQ™ system, based on COTS components and software, is proven and popular in test bench applications. DCUs, ECUs, FADECs and earlier analog or mechanical control units are easily interfaced.

  • Advanced Test Platform

    980 12G - Teledyne LeCroy quantumdata

    The Teledyne LeCroy quantumdata 980 12G-SDI Video Generator / Analyzer module supports video and audio functional testing of next gen broadcast monitors, conversion devices and sources up to 12G-SDI. The module is equipped with four (4)12G-SDI-capable output ports. The output ports can be aggregated for Dual link HD-SDI and Quad link 3G-SDI operation. A genlock input supporting both SD analog black burst and HD tri-level to sync the output clocks with a "house sync" but the module can also run off its internal clock. The module's four (4) SDI input ports can also be aggregated for Dual link HD-SDI and Quad link 3G-SDI operation. For single link operation only port 1 on the input or output is functional.

  • Line Monitor

    LE-170SA - LINEEYE Co., Ltd.

    LE-170SA is a compact hand-held size line monitor for CAN/LIN. It has a touch screen and can be control as for smartfones. It has 1 CAN channel and 1 LIN channel and it can monitor both CAN and LIN communication thus monitoring of the network which has both CAN and LIN is available. The monitor function can diplay the communication data in real-time while saving it. The simulation function can send/receive the test data instead of the original communication partner. The ID filtering and trigger function make your development/evaluation more efficient. It also can measure 4 external signals as degital signals or analog signals while monitoring the communication data.It is light (300g) and convenient for field testing. The line monitor is useful for not only development but also maintenance.

  • Network Analysers

    Algodue elettronica

    DIN 96x96 ultra compact version, only 39 mm depthFully bi-directional four quadrants measurements for all energies and powersMain electrical parameters measured and displayed for a cost-effective consumption analysisVersion for 1 or 5A CT and for direct connection up to 6APossibility to connect by PTUp to 8 MB for data recording (ENH version)Possibility to record all energy counters (ENH version)Up to 24 parameters selectable among real time measurements for MIN/AVG/MAX recording (ENH version)MODBUS RTU/ASCII communication by RS485 port or MODBUS TCP communication by Ethernet portPossibility to manage the instrument in remote mode by WintoolNET software or by Web server interface2 digital outputs, 1 digital input, 1 analog output (optional)

Get Help