Showing results: 631 - 645 of 699 items found.
-
40-190B-101 -
Pickering Interfaces Ltd.
The Single Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190B-001 -
Pickering Interfaces Ltd.
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190B-102 -
Pickering Interfaces Ltd.
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190B-301 -
Pickering Interfaces Ltd.
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Extech 380942 -
Extech Instruments Corporation
The compact Extech 380942 is a 30 Amp mini AC/DC clamp meter. The clamp meter has a remarkable 0.1mA resolution (AC), very low-current sensitivity, and a small diameter jaw designed to reach into small areas. The 30 Amp range with 0.1mA (AC) and 1mA (DC) resolution is optimized for finding problems where very low current variances would be missed by standard clamp meters. This mini clamp meter is useful for troubleshooting tasks in plant maintenance, electrical, HVAC, and telecom work, as well as residential electrical, fleet maintenance, marine, and motorcycle repairs. This CAT III-rated True RMS mini clamp meter comes with test leads, 2 AAA batteries, soft carrying case, and user manual.
-
S -
PJ Electronics, Inc.
Bench size performance & durability with PJ's exclusive/unique High Frequency Technology capable of testing the integrity of any turn to turn insulation, including low inductance windings. These Digital Surge Testers come standard with a rack-mounted, Tektronix TDS1002, 1 Billion Samples/sec, real time, programmable, storage oscilloscope.
-
Eltel Industries
*ARM 9 processor controlled measurements*Measures total burden connected to test sample*Internal data storage facility upto 1 lakh readings*Digital display of test results on 800 x 480 TFT color display.*Latest IEC 61869 / ANSI C57.13-2008 / IS-2705 standards incorporated*VGA Port to interface with bigger display / monitor*Both Voltage & Current Transformer testing with one test set*5 and 1 Amp CT testing using either 5 or 1 Amp standard CT*Identifies ANSI, IEC, IS-P, IS-PR, BS, BS-S, IEC-S, IS, IS-S, AS, AS-M, AS-ME standards for CT & VT*USB memory storage*Available in three versions: AITTS Plus , ACTTS Plus & AVTTS Plus
-
60660 -
Lisle Corp.
Jumpers have tabs for clamping and flat pads to place test leads on. No need to pierce wires or connect multiple jumper wires. Also Includes Test Lead Kit for easily and securely connecting Relay Test Jumpers to a multimeter. Jumper wire may be used between common and open to close the relay circuit for testing and has a test port to easily check voltage. Also provides access for a clamp-on amp meter. Relay Puller Pliers easily remove electrical relays without damage to the relay or electrical box.
-
Ampstik®+ -
SensorLink
Use the Ampstik+ to safely take accurate current measurements when performing high voltage live-line load checks for balancing, switching, or breaking load. This high voltage ammeter measures in every electric utility setting with a linear current sensor to accurately measure .5A to 5000A, while in voltage environments up to 500kV. The opening of the amp sensor is electronically closed, while external currents are electronically rejected. This design enables the user to measure an individual conductor within close proximity to adjacent conductors without interference errors.
-
The Swain Meter Company
The Swain Meter™ Company manufactures portable clamp on DC ammeters that precisely measure the magnitude and direction of DC current flow on any conductor. Used both onshore and offshore, Swain DC clamp on amp meters accurately read current from 5mA to 200 Amps with a resolution of 1mA in the 0-2Amp range.
-
Extech 382202 -
Extech Instruments Corporation
The 382202 is a DC power supply which provides an adjustable 0 to 30 Volts and 0 to 1 Amp output. Features dual backlit LCD display for current and voltage, short circuit and overload protection. Operates from 120VAC ±10%/60Hz power source. Banana plug outputs. Complete with power cord.
-
Yelo Ltd.
The low power series of burn-in and life test systems are designed to test the reliability of low power laser diodes up to 1 Amp in current. The modular design means they can test up to 2,048 lasers, however due to the flexibility of the system, it can be adapted to suit both low volume R&D environments and high volume production environments.
-
MC Model -
PJ Electronics, Inc.
Digital Surge, DC Hi-Pot & Built-In 3 Phase Test Selector Switch all-in-one versatile Tester. The DC Hi-Pot tester has separate panel meters for direct readout (voltage and current) so that no interpretation on the scope's display is ever needed and enables one to ascertain Polarization Index (PI) Test results.
-
PCI Synchro -
Computer Conversions Corporation
Proven "Whole" Std. ConvertersOptimized Thermal ManagementExternal Synchro AMP I/O100% Transformer Isolated I/OPermits 2 wire X/Y Stators(Air)No External Parts or Power RequiredReference Powered(NAVAL) Options10-16 BIT Resolution ProgrammableVirtually Indestructible Outputs1.2 to 4.5VA High Power ModelsMix/Match Input & Output TypesSimultaneous Fine/Coarse Transmit For Multispeed Outputs
-
Cirrus Research plc
Cirrus offers a range of Class 1 and Class 2 hand-held sound level meters and accessories to cover all noise measurement applications from simple noise tests to detailed noise analysis. Our range of Sound Level Meters and Noise Meters spans simple instruments that provide the measurement of Sound Level, Integrating-Averaging instruments that provide Leq and occupational noise functions as well as precision data logging sound level meters with 1:1 & 1:3 real time octave band filters and in-measurement audio recording.