Showing results: 166 - 180 of 694 items found.
-
40-662A-003 -
Pickering Interfaces Ltd.
The 40-662A-003 is a single 16-channel, 1-pole MUX and is part of our range of 16 Amp PXI power multiplexer modules is available in seven configurations ranging from 4-off 2:1 multiplexers to 1-off 16:1 multiplexer.
-
40-662A-013 -
Pickering Interfaces Ltd.
The 40-662A-013 is a single 8-channel, 1-pole MUX and is part of our range of 16 Amp PXI power multiplexer modules is available in seven configurations ranging from 4-off 2:1 multiplexers to 1-off 16:1 multiplexer.
-
40-662A-011 -
Pickering Interfaces Ltd.
The 40-662A-011 is a quad 2-channel, 1-pole MUX and is part of our range of 16 Amp PXI power multiplexer modules is available in seven configurations ranging from 4-off 2:1 multiplexers to 1-off 16:1 multiplexer.
-
40-662A-002 -
Pickering Interfaces Ltd.
The 40-662A-002 is a dual 8-channel, 1-pole MUX and is part of our range of 16 Amp PXI power multiplexer modules is available in seven configurations ranging from 4-off 2:1 multiplexers to 1-off 16:1 multiplexer.
-
40-662A-014 -
Pickering Interfaces Ltd.
The 40-662A-014 is a single 12-channel, 1-pole MUX and is part of our range of 16 Amp PXI power multiplexer modules is available in seven configurations ranging from 4-off 2:1 multiplexers to 1-off 16:1 multiplexer.
-
BRIC -
Pickering Interfaces Ltd.
Pickering's high-density PXI large matrix BRICs offer current handling up to 1 Amp and select models are supported by our Diagnostic Test Tools, Built-In-Relay-Self-Test (BIRST) and eBIRST Switching System Test Tools, these tools provide a quick and simple way of finding relay failures within LXI, PCI and PXI switch systems.
-
40-552-002 -
Pickering Interfaces Ltd.
The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.
-
40-552-001 -
Pickering Interfaces Ltd.
The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.
-
610115125 -
Virginia Panel Corporation
Mini Power contacts carry up to 65 amps continuous current, 480 VAC. Maximum resistance is 1 Milliohms.
-
VERSAPRO3 -
Matco Tools
Multi-function portable power you can take anywhereDesigned to jump start cars, trucks, motorcycles, boats, ATV’s and moreVehicle jump starting and device charging capabilities for all of your portable power needs
-
40-136-212 -
Pickering Interfaces Ltd.
The 40-136-212 19xDPST reed relay module is part of our range of medium power, general purpose relay modules which are capable of switching voltages up to 200V and current up to 2A.
-
40-136-012 -
Pickering Interfaces Ltd.
The 40-136-012 12xDPST reed relay module is part of our range of medium power, general purpose relay modules which are capable of switching voltages up to 200V and current up to 2.5A.
-
40-612A-002 -
Pickering Interfaces Ltd.
The 40-612A Very High Density Versatile Multiplexer module features a wide range of software selectable switching configurations. It is especially useful where a number of high density multiplexers are required with the option of easily altering the channel count as a test system evolves. Typical applications include signal routing in ATE and data acquisition systems. The 40-612 module uses high quality electro-mechanical relays, connections are made via a front panel 160 pin DIN41612 connector. The module can be software configured into one of a large number of different multiplexer modes. Relays allow the multiplexer banks to be set in 1 or 2 pole mode and inter-bank switching enables the channel count to be increased up to a maximum of 128
-
40-667A-012 -
Pickering Interfaces Ltd.
The 40-667A-012 is a single 6-channel 30A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.
-
40-667A-011 -
Pickering Interfaces Ltd.
The 40-667A-011 is a dual 3-channel 30A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.