  • Super Fast Gang Industrial Universal Programmer

    48Pro2AP - Dataman, Inc

    The Dataman 48Pro2AP is a super fast industrial universal programmer with ISP capabilities and USB 2.0 connectivity • Optimised for use in automated handlers and ATE machines • Over 71,000 devices supported with new devices added monthly • Mechanically stable case design with multiple fixing points • ISP capable using the JTAG interface • Hi-speed USB 2.0 connectivity • Easy to use software compatible with the latest operating systems including Windows 10 • Comprehensive 3 years parts and labor warranty • Free life-time software updates

  • PXI MUX 4 Bank 0f 16 Channel 1 Pole

    40-610-021-4/16/1 - Pickering Interfaces Ltd.

    This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer

  • PXI MUX 2 Bank, 32 Channel Screened 1 Pole

    40-610-021-S-2/32/1 - Pickering Interfaces Ltd.

    This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer

  • PXI MUX 1 Bank, 64 Channel Screened 1 Pole

    40-610-021-S-1/64/1 - Pickering Interfaces Ltd.

    This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer

  • PXI MUX 2 Banks of 32 Channel 2 Pole

    40-610-022-2/32/2 - Pickering Interfaces Ltd.

    This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer

  • PXI MUX 1 Bank of 64 Channel 1 Pole

    40-610-021-1/64/1 - Pickering Interfaces Ltd.

    This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer

  • Transformer Oil Dielectric Strength Testing

    LS -JJ-II - Chongqing Lushun Scientific & Technological Development Co., Ltd.

    1.The instrument has the function of automatic detection. 2.Tiny TPU-A panel printer is adopted for automatic printing out type insulating oil dielectric strength ATE is a full self-reacting device, which is developed according to the requirements in International IEC-156 and International GB507-86 "Insulating Oil Dielectric Strength Mensuration", combining the feedback opinions of all users .The instrument adopts singlechip as the leading part, and uses the method of "first setting and then testing". The whole process is controlled by automatic microcomputer. It is operated simply and used conveniently.

  • PXI Single 32x8 Matrix, 1 Pole Switching

    40-531-021 - Pickering Interfaces Ltd.

    Model 40-531 very high density matrix modules are configured as a 32x8, while the 40-532 modules are configured as a Dual 16x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance.

  • PXI Dual 16 x 8 Matrix 1 Pole Screened

    40-532-021-S - Pickering Interfaces Ltd.

    This high-density reed relay matrix with 256 crosspoints. This model is configured as a Dual 16x8, model 40-531 is configured as a 32x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version can be used for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance.

  • PXI Single 32x8 Matrix, 1 Pole Screened

    40-531-021-S - Pickering Interfaces Ltd.

    Model 40-531 very high density matrix modules are configured as a 32x8, while the 40-532 modules are configured as a Dual 16x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance.

  • PXI Dual 16x8 Matrix, 1 Pole Switching

    40-532-021 - Pickering Interfaces Ltd.

    This high-density reed relay matrix with 256 crosspoints. This model is configured as a Dual 16x8, model 40-531 is configured as a 32x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version can be used for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance.

  • PXI Triple 4 to 1 RF Multiplexer 6GHz 50 Ohm SMA Terminated

    40-882-003 - Pickering Interfaces Ltd.

    A 50 Ohm 4 to 1 6GHz PXI RF multiplexer available as a single MUX in one PXI slot, a dual MUX in two PXI slots, or triple and quad MUXs in three slot PXI modules. This PXI multiplexer exhibits low VSWR characteristically over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensures a long service life with no wear out mechanism, making the 40-882 MUX ideal for ATE systems requiring frequent and fast operating RF switching.

  • PXI Quad 4 to 1 RF Miltiplexer 6GHz 50 Ohm SMA Terminated

    40-882-004 - Pickering Interfaces Ltd.

    A 50 Ohm 4 to 1 6GHz PXI RF multiplexer available as a single MUX in one PXI slot, a dual MUX in two PXI slots, or triple and quad MUXs in three slot PXI modules. This PXI multiplexer exhibits low VSWR characteristically over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensures a long service life with no wear out mechanism, making the 40-882 MUX ideal for ATE systems requiring frequent and fast operating RF switching.

  • Wide Range High Voltage Programmable DC Power Supply

    N3600 Series - Next Generation Instrumental (Shanghai) T&C Tech. Co., Ltd.

    N3600 series is developed based on NGI's years of experience in testing for battery fluctuation simulation test, battery charger, high voltage diode, electrolytic capacitor, electromechanical control, ATE test system, etc. It is a high-voltage wide-range programmable DC power supply. According to different test environments in the fields of lab test, system integration test, and mass production line, NGI has made a number of optimization designs based on the international advanced technology. N3600 series is a market leader in similar products in terms of reliability, maintainability and safety.

  • LXI Low Thermal EMF Matrix 1-pole 56x33

    60-510-001 - Pickering Interfaces Ltd.

    The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset.