-
Product
Acute High Voltage Differential Probe, 50x/500x, 25MHz, 3500V
ADP5025
-
*USB Powered (or Power Bank)*Bandwidth up to 25 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation
-
Product
NI-5191, 800 MHz, ±30 V, 10X Attenuation, Differential Active Oscilloscope Probe
781785-01
-
The NI-5191 is a differential, active voltage probe that offers 800 MHz of input bandwidth with a 10:1 attenuation ratio. You can use it with oscilloscopes that provide 50 Ω input impedance. You can power the probe using a Type-N barrel power connector from a USB port or using a 9 V alkaline battery.
-
Product
HandyScope HS6-DIFF With EMI & SafeGround: 1 GS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-1000XMEG-W5
-
The powerful capabilities of the WiFiScope HS6-DIFF-1000XMEG EMI analyzer give the user the possibility to quickly perform a good EMI compliance test. With this cost effective test, time and money are saved by avoiding extra visits to expensive EMC testing facilities. The supplied EMI probe set TP-EMI-HS6 contains three magnetic field (H field) probes and one electric field (E field) probe. The tripod ensures that the probes can be positioned properly at the object under test.
-
Product
CAN/FlexRay/Differential Bus PXI Fault Insertion Switch - 8 Channel
40-200-008
-
This PXI Fault Insertion module is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This module supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses. Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signalling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
20 GHz Differential Probe with ProLink Interface
DH20-PL
-
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
Product
Differential Voltage Probes
DP150/DP200pro
-
The DP differential isolation probes are an important accessory for any laboratory involved in power electronics and high voltage systems. These probes allow isolated and floating measurements with any oscilloscope or data recorder, whilst the oscilloscope can remain grounded. Using a DP150 or DP200pro probe, differential and floating measurements can be made on a variety of ac power systems like 230V/110V ac input power supplies, chopped and switching power supplies, thyristor controllers, variable speed motor drives (PWM signals), motor inrush current and measurement across current shunts. The isolated input is made via two 4mm/banana safety sockets. The BNC output allows easy connection to an oscilloscope. The DP probes can be powered from a 9V battery or external power supply.
-
Product
500 MHz, 1.0 pF Active Differential Probe
ZD500
-
With the ProBus interface, the ZD500, 1000, and 1500 becomes an integral part of the oscilloscope. All probe gain and offset controls are transparent to the user, making it easier to probe the circuit without concern for which gain setting to choose. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
Product
Differential Probe
DP-35
-
*High Sensitivity, High Voltage Model .*35MHz/1600 Vp-p Max.*Input Impedance 8MΩ//2.5PF*x10, x100 Attenuator, Easy to Convert.*Separating Design(Standard No.114205) Convenient & Durable.
-
Product
CAN/FlexRay/Differential Bus PXI Fault Insertion Switch - 4 Channel
40-200-004
-
Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signaling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
PCIe 16 Bit Multi-purpose Digitizer - up to 125 MS/s on 4 Channels (Single Ended) or 2 Channels (Differential)
M2P.5962-X4
-
The M2p.59xx series allows recording of up to eight single-ended channels or up to four differential channels both with sampling rates of up to 125 MS/s. These PCI Express cards offer outstanding A/D features both in resolution and speed. The cards can be switched between single-ended inputs with a programmable offset and true differential inputs. If used in differential mode each two inputs are connected together reducing the number of available channels by half. The 16 bit vertical resolution have four times the accuracy compared to 14 bit cards and sixteen times the accuracy if compared with a 12 bit card. All boards of the M2p.59xx series may use the whole installed on-board memory of up to 512 MSamples completely for the currently activated number of channels.
-
Product
Active Differential Probe, 100 kHz to 12 GHz
U1818B
-
The Keysight U1818B 100 kHz to 12 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818B allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
Product
Gas Differential Pressure Switch
A4
-
Rugged Series A4 Differential Pressure Switch offers field adjustments and can handle system pressures up to 6000 psig. Piston design allows mounting in any orientation. The switch is capable of carrying moderate shock and vibratory loads
-
Product
PCIe 16 Bit Multi-purpose Digitizer - up to 5 MS/s on 4 Channels (Single Ended) or 4 Channels (Differential)
M2P.5916-X4
-
The M2p.59xx series allows recording of up to eight single-ended channels or up to four differential channels both with sampling rates of up to 125 MS/s. These PCI Express cards offer outstanding A/D features both in resolution and speed. The cards can be switched between single-ended inputs with a programmable offset and true differential inputs. If used in differential mode each two inputs are connected together reducing the number of available channels by half. The 16 bit vertical resolution have four times the accuracy compared to 14 bit cards and sixteen times the accuracy if compared with a 12 bit card. All boards of the M2p.59xx series may use the whole installed on-board memory of up to 512 MSamples completely for the currently activated number of channels.
-
Product
Differential Pressure Adapter w/ App Compatibility
DPA1
-
UEi Test & Measurement Instruments
The DPA1 measures positive, negative and differential pressure and is compatible with iOS® and Android™ mobile devices. Measurement units can be selected from the following scales: InH2O, mmH2O, psi, bar, mBar, kPa, InHg and mmHg. The mobile device screen will display a numeric reading. And is backed by a 1-year warranty.
-
Product
16-bit, 400KHz, 4 Isolated Analog Differential Inputs, Simultaneous Sampling
APCI-3003
-
With the new fast A/D converter board APCI-3003, the user can achieve high data transfer rates by a simultaneous conversion of 4 channels at once. The board has 4 differential input channels. Each channel has its own A/D converter. The transfer rate can be set in a flexible way from 100 kHz for each channel, when 16 channels are set, to 400 kHz for each channel, when 4 channels are set. All 4 channels are optically separated from each other up to 500 V.
-
Product
Low Range Low Cost OEM Differential Pressure Transducer
P17
-
The P17 OEM Low Range Low Cost pressure transducer features high sensitivity to very low pressures with full scales available down to 0.1 In H2O. Output signal is 5 Vdc and power can be +5 to +28 Vdc. Zero and Span adjustments are included. The P17 has a robust steel sensor construction.
-
Product
4 GHz ProBus2 Differential Probe with Dx10-SI Solder-In Tip
D410-A-PB2
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Ethernet/LXI digitizerNETBOX 16 Bit Multi-Purpose Digitizer - 125 MS/s on 12 Channels, 80 MS/s on 24 Channels, 24 Single-Ended Inputs, 12 True Differential Inputs
DN6.596-24
-
The digitizerNETBOX DN6.59x series allows recording of up to 48 synchronous channels with sampling rates of 20 MS/s up to 125 MS/s. These products offer outstanding A/D features both in resolution and speed as a remote instrument. The powerful A/D amplifier section offers 6 different input ranges, programmable offset and a software switching from single-ended (full number of input channels) to true differential (half number of input channels).
-
Product
Bus Differential System
B30
-
The B30 features integrated protection, control and metering for MV, HV and EHV busbars, providing cost effective, feature-focused busbar protection. Use the B30 to protect busbars with up to 6 feeders with up to two three phase differential zones. The B30 is a cost effective alternative to high impedance schemes, ideal for breaker-and-half bus schemes, with integrated feeder backup protection and metering
-
Product
VME 16-channel Differential to Single-Ended Signal Converter
V1250
-
The V1250 is a 16 channel differential to single ended signal converter in a 1-unit wide VME 6U form factor. It provides differential inputs (34-pin 2.54 mm header, Zdiff = 100 Ω) and single ended outputs (coaxial LEMO, Rout = 50 Ω).
-
Product
CO2 Air Quality & Differential Pressure Measurement
-
Our Rotronic CO2 and differential pressure instruments complete the PST range of parameters important for environmental monitoring.
-
Product
Differential Calibration Substrates
-
The GGB Industries, Inc., line of DIFFERENTIAL CALIBRATION SUBSTRATES allows the user to calibrate any GGB Industries, Inc., microwave Picoprobe at the probe tip. The underlying principal of the calibration of a measurement system is to provide accurate known standards to which the measurement system can be connected.
-
Product
Compact Economic Differential Pressure Switch
PDPS
-
The Series PDPS's large diameter diaphragm and snap action switch make it dependable and ideal for OEM applications. The Series PDPS Pressure Switches are available for pressure, vacuum, and differential applications and are factory preset for pressures from 0.07 in. of w.c. to 1.0 in. of w.c. with full-scale repeatability of ±0.02 in. of w.c.
-
Product
HandyScope HS6-DIFF With SureConnect: 500 MS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-500XMS-W5
-
The only oscilloscope in the world that has:- SafeGround, differential input channels that can be switched to single ended.SureConnect, auto-detects a true connection between the probe tip and the device under test.- CMI interface.- USB 3.0 interface, 5Gb/s data transfer- Lowest noise
-
Product
HandyScope HS6-DIFF With SafeGround: 100 MS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-100XMG-W5
-
- 1GS/s sampling and flexible resolution of 8-16 bit.- Four input channels up to 250 MHz analog bandwidth- Highly accurate 1 ppm time base- DC Accuracy of 0.25 % and 0.1 % typical- Very fast 200 MSamples per second USB streaming Data logger- Spectrum analyzer with 32 million bins- Optional SureConnect connection test on all channels- Up to 256 MSamples memory per channel
-
Product
Explosion-Proof Differential Pressure Switch
H3
-
Explosion-proof, heavy duty, industrial unit has patented and unique new design which provides sensitivity to differential pressures as low as 10 inches of water (254 mm w.c.), yet handles total pressure of 1500 psi (103 bar). Unlike common differential pressure switches that use a piston-type motion transfer, the Series H3 utilizes a rotary motion transfer shaft that prevents a change in total pressure from causing a setpoint shift.
-
Product
16 GHz Differential Probe with ProLink Interface
DH16-PL
-
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
Product
Differential TDR, 35 ps, 15 GHz, ESD, Sxy, OSLT 3.5MM Cal Kit, Aluminum Case, Internal Battery
T3SP15D-B-BUNDLE
-
Differential TDR,35ps Rise Time, ESD protection,2 phase matched 3.5mm cables,3.5mm Cal. Kit, Battery.
-
Product
PCIe 16 Bit Multi-purpose Digitizer - up to 40 MS/s on 2 Channels (Single Ended) or 2 Channels (Differential)
M2P.5931-X4
-
The M2p.59xx series allows recording of up to eight single-ended channels or up to four differential channels both with sampling rates of up to 125 MS/s. These PCI Express cards offer outstanding A/D features both in resolution and speed. The cards can be switched between single-ended inputs with a programmable offset and true differential inputs. If used in differential mode each two inputs are connected together reducing the number of available channels by half. The 16 bit vertical resolution have four times the accuracy compared to 14 bit cards and sixteen times the accuracy if compared with a 12 bit card. All boards of the M2p.59xx series may use the whole installed on-board memory of up to 512 MSamples completely for the currently activated number of channels.
-
Product
PCIe 16 Bit Multi-purpose Digitizer - up to 20 MS/s on 4 Channels (Single Ended) or 4 Channels (Differential)
M2P.5926-X4
-
The M2p.59xx series allows recording of up to eight single-ended channels or up to four differential channels both with sampling rates of up to 125 MS/s. These PCI Express cards offer outstanding A/D features both in resolution and speed. The cards can be switched between single-ended inputs with a programmable offset and true differential inputs. If used in differential mode each two inputs are connected together reducing the number of available channels by half. The 16 bit vertical resolution have four times the accuracy compared to 14 bit cards and sixteen times the accuracy if compared with a 12 bit card. All boards of the M2p.59xx series may use the whole installed on-board memory of up to 512 MSamples completely for the currently activated number of channels.





























