-
Product
Transformer Insulation Testing
-
The primary test methods used to assess the condition of the active insulation components in transformers and bushings, on site, include:1) power factor/tan δ,2) variable frequency power factor/tan δ (1 - 500 Hz)3) dielectric frequency response (DFR) [a dielectric response method], and4) moisture in oil measurements (for transformers).
-
Product
Split type AC Current Transformer
CTS-100
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*1A output for metering application.*Short circuit switch for secondary output is provided for safe operation.*High accurate transformer for the application of first class meter.*Easy installation by metal fitting.
-
Product
Transformer Protection
-
Schweitzer Engineering Laboratories, Inc.
Transformer protection products and systems provide complete primary and backup protection for all types of transformer faults. They are suited for use in utility-, industrial-, and commercial-scale power transformer systems.
-
Product
Antenna, Active Loop
EM-6869 | 9 KHz – 50 MHz
-
The Electro-Metrics EM-6869 Active Loop Antenna is used with any receiver or spectrum analyzer with 50 ohm input and covers the frequency range of 9 kHz to 50 MHz.
-
Product
Partial Discharge Detection and Localization System for Power Transformers
AE-150™
-
The AE-150™ is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors’ data. The AE-150™ has many acquisition modes, each used for detecting and locating Partial Discharge activity in a transformer. The AE-150™ unit is mounted on the transformer tank using its powerful magnets that also hold four acoustic sensors. Acquired data is sent to Mirador-Tx software where all advanced positioning functions are implemented. This cutting-edge software allows easy data interpretation, reporting and monitoring.
-
Product
Vertical Space Transformers
ST
-
The Space Transformer (ST) is an integral part of the probe card, utilized between the probe head and the PCB. Nidec SV Probe provides a wide variety of space transformation options including: • WST™ (Wired Space Transformer) • MST™ (Modular Space Transformer) • MLC (Multi-Layer Ceramic) • MLO/Mini-PCB (Multi-Layered Organic) • Multi-Site MLO Reflow of Package Substrate • MLC with MLTF to 50µm PitchOne of the main priorities for Nidec SV Probe is the internal development and manufacture of our own probe card components. We now offer in-house manufactured space transformer technologies with shorter lead time and competitive pricing. Contact your sales representative to learn more about our internally manufactured STs or any of our other ST technologies.
-
Product
Transformer Oil Acidity Testing Kit
-
NMC Brand Transformer Oil Acidity Testing Kit used to measure the Acidic content of Transformer Oil
-
Product
Transformer Winding Resistance Meters
RMO TT Series
-
The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.
-
Product
ANSI Metering Current Transformer Burden
-
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
Product
Transformer Monitoring
-
MTE offers a broad range of products and solutions for the online gas-in-oil monitoring of transformers (online DGA). With its individual and modular system components MTE provides the optimal customer oriented solution for utilities, industries and transformer manufacturers.
-
Product
Phase Shifting Transformer
-
Supreme Instrument Laboratories
Supreme make PHASE SHIFTING TRANSFORMERS are special transformers which provide convenient means to adjust phase angle (power factor) of A.C. loading circuit while testing power factor sensitive device for the full 90 degree LAG through '0' degree to 90 degree LEAD. Based on their rating these Phase shifters are manufactured in two configuration.
-
Product
Multi Mount Transformer
UET101
-
UEi Test & Measurement Instruments
Multi Mount Control and Ringer transformer.
-
Product
Transformer Testers
-
*Quickly tests deenergized power distribution transformers*Briefly energizes the transformer and takes a snapshot of the condition by measuring the voltage, current and power factor of the test signal*Tests overhead, pad-mount and distribution transformers*Audible alarm confirms successful test*Improve SAIDI statistics by quickly testing and getting the transformer back in service*Auto self-test performed with every test*Compact, lightweight and easy-to-use
-
Product
Precision Multirange Current Transformer
P-2000
-
The Type P-2000-2 Knopp Precision Current Transformer is useful for high and low voltage work in the laboratory, shop and field for testing, measuring, and calibrating. The excellent accuracy and the One-to-One calibrating feature make it admirably suited as a standard for calibrating work.
-
Product
Transformers (Murata Power Solutions Products)
-
Murata transformers are ideally suited to high-frequency designs. The products come in a variety of industry-standard packages and can be used in applications where impedance matching, voltage conversion, isolation and current sensing may be required.
-
Product
Control Transformers
-
ENTES control transformers ensure the safe operation of measuring devices with 24 VAC supply voltage for electical control panels. Input voltages of Control transformers are either fixed (230 or 400V) or selectable with taps (400;230+15-15).
-
Product
Epoxy Resin Silicon Rubber Outdoor Voltage Transformer
JDZW-10RG
-
Beijing GFUVE Electronics Co.,Ltd.
Outdoor voltage transformer of the type JDZW-10 is single phase and epoxy resin silicon rubber insulated product, it's used for metering electric energy, voltage control and relay protection in 50/60HZ rated voltage less than 12kV electric system. It can be used for medial voltage AIS, or can be used for medial voltage switchgears. They can operate in all kinds of environments (such as wide range temperature (-50~70℃), high altitude, high humidity, high pollution or salt). This model JDZW-10 outdoor voltage transformer is also as voltage source to supply 220V voltage.
-
Product
Split-Core Current Transformers
CTS Series
-
Continental Control Systems LLC
The CTS series CTs are available with windows from 0.75 inch up to 2.0 inch. They have a removable section, so that they can be installed without interrupting the circuit. 0.333 Vac output at rated current Accuracy ±1% from 10% to 100% of rated current Phase angle <2° degrees at 50% of rated current (valid for 70 A or higher) 8 ft. twisted-pair wire, 600 Vac rated UL recognized for voltages up to 600 Vac, CE mark, RoHS
-
Product
High Frequency Current Transformers
-
Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.
-
Product
Current Transformer
CT
-
The split-core current transformers are easily installed with the snap on design.
-
Product
Closed Loop Hall Effect Current Sensors/Transducers
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor
-
Product
Transformer Test System
-
Transformer testing instrument, can be used as a stand-alone device and has the highest efficiency. Can be used in power transformers, network communication transformers, etc.
-
Product
Automatic Transformer Tester
SS3250 / SS3252 / SS3302
-
Automatic transformer test instrument is a precision test system, designed for transformer production line or incoming/outgoing inspection in quality control process, with high stability and high reliability. With the enhanced capability in turn ratio measurement, they can solve the measuring problems of low coupling coefficient, transformer's turn ratio and turn number with more precise measurement.
-
Product
IEC Potential Transformer Burdens
-
• Burdens for IEC specifications rated for various input voltages available • 2.5 to 207.5 VA at 0.8 PFIEC Potential Transformer Burdens
-
Product
Fourier Transform Infrared Spectroscopy (FTIR)
-
Rocky Mountain Laboratories, Inc.
FTIR Analysis is used to analyze organic materials. Bulk and small particle materials can be analyzed. FTIR microscopy analysis allows for the identification of particle as small as 10 µm.
-
Product
Clamp-On / Precision / Split Core Current Transformer
-
Transformer Ratio (Arms) : 100A / 1AColours : Red, yellow, blueConnection : Safety Sockets for Banana Plugs ф 4mm Jaw Opening : Cable Dia 15mm max.
-
Product
Range Extension Transformer
-
• Range extension transformer to extend the capacitance range upto 2.6 micro Farad (ACTS-12K) and 2.4 micro Farad (CTS-12KSA)
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TT Series
-
RMO-TT series is perfect for measuring winding resistance of inductive objects such as power and distribution transformers or autotransformers. Additionally, every transformer resistance meter from RMO-TT series can analyze:tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.Transformer demagnetization can also be performed with all RMO-TT instruments.The series is consisted of 3 models, with maximal test current from 40 A (RMO40TT) to 100 A (RMO100TT). RMO100TT is the only portable transformer resistance meter in the market with 100 A DC output current.The three independent channels enable testing of three windings in series. Consequently, a user can measure winding resistance in every tap position of an on-load tap changer without discharging between the tests.In addition to winding resistance measurement, a user can perform a detailed on-load tap changer analysis by analyzing recorded graphs (10 kHz sampling rate) and by measuring vibrations on an external tap changer tank.All RMO-TT instruments have a built-in tap changer control unit. Because of this, it is possible to remotely control on-load tap changer (OLTC) directly from the device. Also, a user can program DV-Win software to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
Product
High Impedance Transformers
-
Osborne high impedance transformers are used to step-up, step-down and isolate voltages in single phase and three phase circuits. A properly designed high impedance transformer can be used an an equivalent to an isolation transformer connected in series with an inductor. The high impedance characteristic may be employed as a current limiting feature in both the primary and secondary circuity.
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
-
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.





























