-
Product
Tunable, Pulsed IR SW & LW OPO IR Source
Firefly-IR
-
Firefly IR is available in short-wave and long-wave models, providing broad wavelength coverage from 1.4-8.5 µm. The compact and sealed design requires no manual alignment, and can be used in a variety of applications in the lab and in the field. Wavelength selection and scanning is automated and performed via web browser or using a TCP/IP command set. Pulsed operation and high repetition rate provide high peak power and rapid data acquisition.
-
Product
Pulse Generator
PulseGen
-
Pulse Generator for use with an oscilloscope as a Time Domain Reflectometer (TDR).
-
Product
Pulse Concentrator
-
1) Total counter indexes of 12 pulse inputs with tariff and unit information, date and time information and alarm states can be displayed on the 2x12 characters LCD screen automatically with intervals of 5 seconds or manually by pressing up and down buttons,2) Enabling the backlight for 20 seconds by pressing any button to provide easy reading on the screen,3) Data communication with a PC via RS-485 output,4) Storing the contents of each pulse input with tariff information in 1-60 minutes intervals on the 2 MB permanent memory of the device with date and timeinformation,5) Preventing changes to settings by unauthorized users by defining a 4-digit user password.
-
Product
Pulsed High Field Magnetometer
TPM
-
This is the equipment evaluating the magnetic properties of rare-earth such as Js, Jr, Hcb, Hcj, (BH)max, HK and SR etc.
-
Product
Flex Power Right Angle Non Shut-Off Pulse Tools
-
The non shut-off right angle pulse tools are ideal selection when the operator needs to control the fastening process. It offers access for hard-to-reach fasteners in tight spaces. The drive on a right-angle tool is mounted at a 90-degree angle to the tool body. Designed for safe, reaction free operation for various industrial assembly applications. The FlexPower Pulse Tools provide operators with an industry leading power-to-weight ratio, allowing for a smaller tool selection for greater torques giving operators a lighter tool with more torque capability. Ergonomically safer than harmful hammering and vibration of impact wrenches. Built for durability with a superior O-ring design and specially designed pulse fluid FlexPower extends life between regular oil changes and provides more torque stability. Low noise decibels, minimal vibration and low torque reaction. It is important to understand your joint application before a selecting a pulse tool.
-
Product
Ultrafast Laser Pulse Measurement
FROG Scan
-
Our FROG Scan system is versatile, adaptable and easy to use. With our FROG Scan, you can tweak a laser system or measure highly chirped pulses to calculate the amount of dispersion compensation you might need for recompression. Measure a short pulse that has been chirped out to several picoseconds, or measure pulses as short as 12 fs in real-time.
-
Product
Logic Analyzer & Digital Pattern Generator
ScanaQuad Series
-
ScanaQuad (SQ) is a series of high performance 4 channels logic analyzers and digital pattern generators. They are designed to be your best companion when working on serial protocols like UART, SPI, I2C, 1-Wire, USB, I2S, CAN, LIN, RS232, RS485, and more. With ScanaQuad Logic Analyzers, you can capture signals, you can play them back, and you can even build genuine test signals and generate them!
-
Product
Pulse Function Arbitrary Noise Generator
81150A
-
1 - 120 MHz pulse generation with variable rise/fall time1 - 240 MHz sine waveform output14-bit, 2 GSa/s arbitrary waveforms512k samples deep arbitrary waveform memory per channel Noise with a selectable crest factor and signal repetition time of 26 days FM, AM, PW, PWM, FSK modulation capabilities up to 10 MHz1 or 2 channel, coupled and uncoupled Differential outputs
-
Product
Pulsed X-ray technology
-
Golden Engineering X-ray generators are based on Pulsed X-ray technology. Pulsed X-rays generate a high intensity X-ray burst (pulse) in a very short period of time (10 to 50 nanoseconds depending on the model). The output dose of each pulse is 3-6 mR measured 12 inches from the front of the X-ray generator. The operator varies the overall dose of each exposure by changing the pulse setting. The pulse rate varies from 10 pulses per second to 25 pulses per second depending on the model. The generators can fire up to 200 pulses before a four-minute rest period.
-
Product
JESD22-A115 Machine-Model (MM) Pulse Emulator
MM-10A
-
High Power Pulse Instruments GmbH
- Pulse unit to generate JESD22-A115 machine-model (MM) waveforms with TLP- Extremely stable and reproducible machine-model (MM) waveforms- Compatible with HPPI TLP-3010C/4010C/8010A/8010Csystems which have installed pulse width of 25 ns and rise time of 100 ps to 300 ps- Up to ±10 A machine-model peak current with TLP-3010C, which is equivalent to ±667 V (MM)- Up to ±15 A machine-model peak current with TLP-4010C, which is equivalent to ±1000 V (MM)- Up to ±30 A machine-model peak current with TLP-8010A and TLP-8010C, which is equivalent to ±2000 V (MM)- Same measurement procedure as TLP including DC test of the DUT- Compatible with HPPI TLP software and waveform data storage and management- 50 Ω SMA input and output connectors- Compact size: 61 mm x 25 mm x 17 mm
-
Product
30 Amps, 100 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse
CP031
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
Pulse & Delay Generators
-
The benchtop pulse generators feature a fast risetime and low jitter. Our most popular digital delay pulse series 575 and 577 generators are now available with selectable time references. With up to eight channels of delay and width control, each individual channel's reference can be set either to the trigger or to any other channel. So look below if you require a picosecond pulse generator or nanosecond pulse generator for your application.
-
Product
PXIe-4139 , ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit
782856-03
-
PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 40 W of DC power. This module features analog-to-digital converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. You can use the PXIe-4139 for applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
Product
150 A, 10 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 2 meter cable
CP150B
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
PXIe Precision Source/Measure Unit, 15 MSa/s, 100 FA, 60 V, 3.5 A DC/10.5 A Pulse
M9603A
-
The Keysight M9603A is a PXIe precision SMU featuring best-in-their-class narrow pulse width as narrow as 10 μs. It enables dynamic/pulsed measurements with up to 15 MSa/s for broad emerging applications such as VCSEL optical devices.
-
Product
IMPATT Noise Generator CW & Pulse At W-band, 94 GHz :
-
The device consists of two modules, a cable that connects them, and a power cable. The first module (I) contains the power supply (AC 115 V), regime switch mechanism and a generator of a series of pulses. The second module (II) is the noise generator. Photo 1: Module I - Power Supply
-
Product
Sophisticated Audio and Video Test Patterns
VQL
-
VQL Instantly reveals your video display, codec, scaler, converter or other video device performanceVQL test patterns cover all 3 levels of video QA/QC:Instant visual-aural Quality EstimationObjective Measurements of video and audio performanceFully automated (unattended) Quality ControlVQL features:Compatibility with all commonly used software or hardware codecs and media playersVideoQ VQV / VQMA / VQTS / VQDM compatible testsWide range of video frame sizes: from 192x108 to 4096x3072Variety of bit rates up to uncompressed 4:4:4 4K @60 fps, 48 bit per pixelVariety of video and audio formats, color spaces and level schemesAll test patterns remain suitable for accurate measurements even after low bitrate coding, heavy scaling and/or cropping, e.g. after down-conversion for mobile devicesStandard, custom and semi-custom tests for development labs, content processing facilities, CDN systems, software developers and high volume manufacturers
-
Product
Pulse Evaluation Systems
-
*Intuitive, user-friendly handling*Integrated wide-range power supply*Easily programmable output functions*Devices for monitoring standstill, speed, direction, slip, and frequency*Switching relays and transistor outputs, scalable analog output
-
Product
Pulse Magnetrons Up To 220 GHz And Peak Power Up To 10 MW
-
Insight Product Co. offers 7 pulse magnetrons models for industrial and scientific applications.
-
Product
Turn Key Laser and LED Sources with Picosecond Pulse and Repetition Rate up to 100 MHz
DeltaDiode
-
DeltaDiodes utilize laser diode and LED technology to generate short optical pulses over a very wide range of repetition rates and wavelengths. Optical pulses as short as 50ps can be generated at repetition rates up to 100MHz.
-
Product
Dual Digital Aquisition System For Charge Integration And Pulse Shape Discrimination
DT5790
-
The DT5790 operates upon the DPP-PSD firmware, specially developed for Charge Integration and Pulse Shape Discrimination. DPP-PSD is based on an advanced on line Digital Dual Gate Charge Integration allowing an effective data analysis even at high count rate. It performs input signal baseline calculation, self-triggering and double-gate charge integration with programmable parameters, double integration of both prompt and total charge for Pulse Shape Discrimination and pedestal subtraction for energy calculation.
-
Product
Pulse Shaping Modules
-
Components—often filters or digital signal processing (DSP) units—used in communication systems to modify the shape of transmitted pulses to optimize spectral efficiency and reduce interference.
-
Product
Split type Pulse Current Sensor
CTF-05T
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
For detecting current pulse with open collector output (for power pulse)
-
Product
4-Axis Pulse Motion Controller
AMP-104C
-
The AMP-104C is a cost-effective 4-axis motion controller card with a PCI Express® interface that can generate a pulse train up to 4.9MHz to control a motor. With more general purpose IOs and 4-channel encoder feedback input, the AMP-104C can be used for a multitude of scenarios or applications. As a motion controller, the AMP-104C provides non-symmetric acceleration and deceleration speed profile settings, T-curve and S-curve speed profile control, and selection of motion stop method.
-
Product
Ultrafast Laser Pulse Measurement System
FROG Scan Ultra
-
With a slightly larger format than our high value FROG Scan system, our FROG Scan Ultra platform allows any Ocean Optics spectrometer to be used (including the QE65000 and InGaAs models). This means higher resolution and the availability of InGaAs detectors for your ultrafast laser system. It can measure pulses from nearly 4 ms (custom systems only) to as short as 450 nm.
-
Product
12-Bit, 2.5 GSPS Digitizer Optimized for Pulse Detection
ADQ32-PDRX
-
ADQ32-PDRX acquires the input signal via a single connector and uses an onboard splitter to separate the signal into two paths with different gain settings. The high gain path is used to accurately capture low-amplitude portions of the input signal whereas the low gain path ensures the acquisition of high-amplitude peaks without causing saturation. The two signal paths are then combined in real-time inside the onboard field-programmable gate array (FPGA) to create a digitized output with improved performance.PDRX increases the dynamic range by 3 bits and is fully integrated into the digitizer for fast and easy system-level integration. ADQ32-PDRX is therefore comparable with a 16-bit digitizer in terms of dynamic range, but with the benefit of offering a higher sampling rate.
-
Product
Pulse Adapter
CV30 P300
-
Frothingham Electronics Corporation
The CV30 P300 test station is the highest current 30KW pulser in a series of exponential pulse generators that can be connected to our FEC200E tester. This gives you all the versatility of the proven FEC200 with the addition of high power exponential pulses. For exponential pulses up to the 10/1000, the station can produce 30KW, 1000A, or 300V whichever is the most limiting. The station can also include all of the usual FEC200 tests in the same test program.
-
Product
System Tests Radar Pulse Stability
PN9002
-
Noise eXtended Technologies S.A.S.
The cost-effective PN9002 test simplifies the testing and analysis of pulse-to-pulse amplitude and phase stability for radar systems and components to 18GHz.
-
Product
Partial Discharge Pulse Calibrator
TPK
-
Partial discharge puls calibrator TPK is a battery-powered handheld device for determining the correction factor in a Partial Discharge test circuit and to verify the Partial Discharge measurement.
-
Product
Beam Pattern Measurement System
BP100
-
The BP100 is purpose-made for luminous intensity measurement of lamps, using a diffusely transmitting screen to provide a flat image that can be measured by an imaging photometer. This is a low cost, versatile solution in comparison to the traditional method of measuring lamp properties as a function of angle of emission, using Goniometers that are often costly and dedicated for one specific measurement.





























