Product
Automatic Battery with Filters with Standard Contactors
BATLVF1000
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralizedcompensation of power factor in low voltage instalations.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2T
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
ITA, G10, 10 Module, 0.5" Standard thickness
410104123
-
ITA, G10, 10 Module, 0.5" Standard ThicknessUses VPC 90 Series Modules.
-
Product
Standard Pitch Spring Probes
-
Other than spring probes with gold plating, we have spring probe with anti-solder migration coating and plating that were developed by KITA. We also have anti-solder migration material for plunger tip. These are all included in “MARATHON” series. They have wide range of tip type for various use for every popular total length.
-
Product
O.E.M. Optical Standards
-
O.E.M. Optical Standards by Applied Image - Boston Scientific Checkerboard Array, Cognex Glass Calibration Plate Set
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
-
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
DC Josephson Voltage Standard
-
The system enables a number of calibration and measurement functions for dc voltages:*Calibration of secondary standards*Calibration of linearities and accuracies of dc voltmeters in the measuring range from 0 to ± 10 V.*Extremely exact output of any reference voltages*Direct comparison of two voltage standard measuring systemsNo other measuring system in the world offers such a variety with the highest precision.
-
Product
Standard M18 Cylindrical Photoelectric Sensors
-
Contrinex Standard M18 Cylindrical Photoelectric Sensors
-
Product
NBS-Series Cryogenic Primary Noise Standards
-
The NBS-Series provide the ultimate accuracy when measuring extremely low noise figures (noise temperatures).
-
Product
4210A Rubidium Frequency Standard
-
Precise Time and Frequency, Inc.
The ptf 4210A Rubidium Frequency Standard is a unique solution for providing a highly stable, low phase noise, frequency reference for applications requiring atomic reference stability performance.The instrument contains a high performance rubidium module, with an extended life design, and very low aging rate, with high quality OCXO o/p for low phase noise.
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF1200
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralizedcompensation of power factor in low voltage instalations
-
Product
Software Development Standards Compliance Solution
-
The most comprehensive development compliance solution; FDA, DO-178B/C, MISRA, JSF, PCI-DSS, ISO, IEC, and more. ntegrate compliance policies into the SDLC and team workflow. Accurately and consistently automate verification and validation tasks
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T156
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
European Standard for Remote Reading of Measuring Devices
M-Bus
-
M-Bus (Meter-Bus) is a European standard for remote reading of measuring devices. M-Bus is predominantly used in buildings, for example in electricity meters, gas meters, water meters or other types of consumption meters. It is also used for various sensors and actuators.
-
Product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1V1S
-
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
Standard Test Devices
-
Zhengzhou SMS Electric Co.,Ltd
Fast, accurate verification to ensure that all devices work reliably.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) Bead Probe
BTP-1HF-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 6.20 (175.20) - 8.00 (226.80) High Frequency Probe
CSP-40A-015
-
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 275 (6.99) including travel of probes
-
Product
Oil Immersed Transfer Standard
esi SR1030 Series
-
The esi SR1030 transfer standards consist of 12 equal steps. These steps are available in increments of 1 (SR1030-1), 10 (SR1030-10), 100 (SR1030-100), 1k (SR1030-1k), 10k (SR1030-10k) and 100k (SR1030-100k). The esi SR1030 provides four-terminal connections for each step or for series and parallel combinations of these resistance steps using the optional Series-Parallel (SPC102), Parallel Compensation Networks (PC101) and shorting bars (SB103). This improves power dissipation, stability and errors due to variance in temperature. The esi SR1010 and esi SR1030 are used for the same applications and are alike in configuration. The esi SR1030 differs from the esi SR1010 in that it is specially sealed, and values below 100 k are filled with oil to improve changes due to thermal variations.
-
Product
Standard CT
2000A
-
• High accuracy of 2000/5A (0.05%) • multiple ratios • Various Current ratings
-
Product
Standard & Custom Test Fixtures
-
Both standard and custom Test Fixtures from OAI enable the user to integrate the solar cell with the I -V tester. Fixture configurations range from from simple hold down devices to temperature-controlled fixtures with front and back side contact. We invite you to contact an OAI Application Engineer for help with your fixture design. With our expert guidance, you can expect maximum performance from your I -V Tester and Solar Simulator.
-
Product
Conformance Calibration Standard Test Card for GS1-DataBar Symbol Verifiers
AI-CCS-DATABAR
-
This test card is ideal for testing verifiers, scanners, and other GS1-DataBar barcode reading equipment. It also can serve as an excellent training aid to ensure new operators are using the proper methodology and are proven competent in the use of verifiers.
-
Product
Standard - 22.08 (626.00) - 220.80 (6259.60) Godzilla High Current Probe
HC500F
-
Current Rating (Amps): 150Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 260Full Travel (mm): 6.60Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,215Overall Length (mm): 81.66
-
Product
Standard- 27.20 (771.00) - 64.00 (1814.00) Godzilla High Current Probe
HC375F-4
-
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
Product
Standard Voltage 37 Pin D-Type Cables - Connector to Unterminated
-
The connector to unterminated cable assemblies below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39L15-5.4
-
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2F
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard 0.95 (26.90) - 4.50 (128.00) Battery Probe
CP-2SB-12
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 128Full Travel (mm): 3.25Recommended Travel (mil): 118.1Recommended Travel (mm): 3.00Overall Length (mil): 472Overall Length (mm): 12.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Four Terminal Pair Standard Resistor Set
42030A
-
The 42030A is a standard resistor set consisting of nine precision resistor standards which range from 1 mΩ to 100 kΩ. These resistors are primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) Bead Probe
BTP-1HC-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02