Product
Temperature Calibration
-
Trescal provides full Temperature Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Temperature Calibration services can be delivered at your site or at our lab. Accreditations for our temperature calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Standard - 5.00 (142.00) - 8.30 (235.00) Feed Through Probe
P3325-0
-
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 645Overall Length (mm): 16.38
-
Product
Testing And Calibration Services
-
Radian Research provides a broad range of unrivaled value-added servicesincluding calibration services done by laboratory and on-site, utilitymanagement training, product training and more.
-
Product
Standard Control and Alarm Panel
8040
-
From our range of B/W Controls products we can supply the 8040 Series control panel with control relay, wired terminal block, motor starter, or a panel for just the external connections.Included in the 8040 Series standard control and alarm panel is the B/W system wiring diagram which assures quick and easy installation and the confidence that the system will work right the first time.
-
Product
Automated CMM Calibrated for High-Production Shop Floor Inspection
CMM Master
-
The CMM Master provides process control by delivering optimal price and performance to your application. The system brings highly repeatable, thermally insensitive, versatile, and programmable inspection to the shop floor.
-
Product
Insulation Tester Calibrator
M191
-
High resistance calibrator for insulation testers up to 10 kV. Other insulation related functions include HV capacitance, short current, dielectric and polarization parameters and timer test.
-
Product
Standard Test Systems
WaveCore™ Products
-
Textron Systems’ WaveCore family offers a variety of standard test systems with a primary application of satellite payload lab testing. Our systems can be deployed affordably for both production and engineering applications, providing industry-leading levels of data correlation with high system mean time between failures and low mean time to repair.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1Z1-4-S
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Resistor Oil Bath
9400
-
Measurements International Ltd.
Measurements International’s series of fluid baths are used for the maintenance of standard resistors and shunts. The 9400 has been designed after compiling years of customer feedback on existing resistor oil baths.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25I35-4
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard CW Amplifiers
-
The BT-AlphaA-CW series is a range of classAB RF power amplifiers covering the 10kHz to1MHz frequency range. Rugged, solid-state design - high reliability. Extremely high phase and amplitude stability. High linearity. In-Built Protection. Very fast blanking. Capable of pulsed operation. Competitively priced. Suitable for CW radar, communications, HF/VHF jamming, particle accelerator applications/plasma systems, plasma, RF heating and other scientific applications.
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72T38-4
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Testwave Calibration
-
Testwave® LLC calibrates electronic, physical, & dimensional test equipment. Our Sparks facility includes a state-of-the-art temperature controlled calibration laboratory, which holds the temperature to within +/- 0.5°C. We send you recall notices before your equipment calibration expires, and if we don’t hear from you, we will call, to make sure you stay in compliance with your calibration requirements. Calibrations are performed at your facility, or at our Sparks Nevada laboratory.
-
Product
Trace-Level Dilution Calibrator
Model T700U
-
Teledyne Advanced Pollution Instrumentation
The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources.In addition to the features of the Model T700, the Model T700U is designed for the demanding requirements of trace-level measurements. The ability to calibrate and verify linearity for NO2 at levels below 50 ppb is difficult with standard calibrators. To overcome this limitation, the Model T700U ozone generator operates in two modes; a high range with similar performance to the Model T700 ozone generator, and a low range, or "fractional" mode, for producing accurate ozone levels down to 3 ppb. To ensure the highest accuracy of NO2 output, the calibrator measures the ozone concentration prior to performing a GPT, and the range is selected automatically by the Model T700U based on ozone concentration and flow specified by the user.
-
Product
GFS Primary Gravimetric Flow Standard
-
The GFS dynamic gravimetric mass flow calibration system allows users to maintain the accuracy and traceability of molblocs or other high precision devices using the same primary reference used by Fluke Calibration. GFS is a true mass flow reference suitable for use in premier measurement institutes who require the lowest measurement uncertainty.
-
Product
Standard 0.87 (24.70) - 5.40 (153.00) Battery Probe
BIP-12
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Resistance Remark: Probe Resistance Steel: 30 mOhms, Gold plated: 100 mOhmsTest Center (mil): 260Test Center (mm): 6.60Full Travel (mil): 394Full Travel (mm): 10.00Recommended Travel (mil): 315Recommended Travel (mm): 8.00Overall Length (mil): 1,220Overall Length (mm): 31.00
-
Product
Resistor Calibration Box
RCB-411
-
Standard Electric Works Co., Ltd
● The RCB-411 is used to verify and proof High Voltage Insulation Testers. Both Analogue and Digital Insulation Testers can be calibrated.● Caution: a. Before testing, make sure the front panel, terminals are clean and dry. If not, wipe them with cloth. b. Use high voltage silicone wires. Otherwise the reading will be incorrect.
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Non Replaceable General Purpose Probe
MEP-20G
-
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 25Test Center (mm): 0.635Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 750Overall Length (mm): 19.05Rec. Mounting Hole Size (mil): 20.5Rec. Mounting Hole Size (mm): 0.52Rec. Mounting Hole Remark: 20.5 to 21.5 mil / 0.52 to 0.55 mmRecommended Drill Size: #75 or 0.52 mm
-
Product
IndySoft for Calibration Management
-
The IndySoft Calibration Management workflow offers a rich feature set to manage the entire lifecycle of your quality assets. With support for leading enterprise platforms it's perfect for deployment in the corner lab of a startup manufacturing facility or a multi-site international quality-driven operation. With the IndySoft exclusive process modeling engine, companies can re-configure the event-driven workflows with checkpoints, rule sets, and documentation at every point along the equipment path, ensuring assets are handled according to their exacting requirements.
-
Product
CPSI-S.0 Standard Compliant Peripheral Board Controlled by a PCIe Channel Derived from a Backplane Connector P1
MIC-3811
-
It is a dual mini-PCIe carrier board with two onboard SIM card holders and mini-PCIe connectors, routed by PCIe and USB2.0 interface. It allows connection with different types of Mini PCIe form factor add on cards like Wi-Fi/3G/4G LTE/GPS/DIO/CAN/ and MVB modules, either full- or half-size style.
-
Product
Kit, Cable Assembly, SH-37F-OM6/4, 9219 Calibration Cable Kit
146907-01
-
Kit, Cable Assembly, SH-37F-OM6/4, 9219 Calibration Cable Kit
-
Product
Portable Analyzer and Calibrator
-
ECD’s portable analyzer and calibrator product lines are a simple convenient way to obtain fast, accurate pH and ORP measurements. They provide a milliVolt output signal for fast field analysis of samples, calibration verification, or trouble-shooting of installed sensors.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74C
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Calibration Lead - Precision Resistor Modules
40-975-037-1m
-
The cable assembly is specifically designed to connect to the 37-Pin D-Type calibration port located on the front panel of Pickering Interfaces Precision Programmable Resistor Modules 40-297 and 50-297 enabling calibration via an external DMM.
-
Product
Cryostat Calibrators
-
Electronic Development Labs, Inc.
Specialized, low-temperature, passively cooled, or liquid nitrogen-based apparatuses designed to calibrate temperature sensors (RTDs, thermocouples, PRTs) at cryogenic levels.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1B-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72T1-4
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Standard 1.68 (48.00) - 3.20 (91.00) General Purpose Probe
HPA-52T
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3H
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02