-
Product
AC Load Bank (Rack Mounted)
K-1000 Rack Mounted
-
Kongter Test & Measurement Co., Limited
Rack mounted resistive load bank is widely used in data center to simulate electric loads and dissipation of IT systems. These load banks are controlled by sectional steps with customized setting. Users could set power and time as per their needs with easy operation.
-
Product
PXI 4 Banks of 20 Channel 1 Pole MUX
40-615-021-4/20/1
-
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
Product
Resistive & Capacitive AC Load Bank
RCD
-
RCD AC load banks are used to test the REAL working condition of UPS, rectifier, inverter and etc who are loaded by non-linear or electronic load with non-constant resistance such as computer, networking equipments and etc. Through the accurate detection of its output and power quality, users could avoid the inadequate loading capacity or cause pollution to power grid, so as to guarantee supply security. JUNXY RCD load banks leading power factor loads are created to debug power supply system parameters such as its crest factor test.
-
Product
PXI 4 Banks of 40 Channel 1 Pole MUX
40-615-022-4/40/1
-
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
Product
PXI 1 Bank of 160 Channel 1 Pole MUX
40-615-022-1/160/1
-
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
Product
Extended Battery Banks
-
Falcon Electric’s extended battery banks provide extra battery runtimes from minutes to hours with our SSG and SSG-RP online industrial UPS systems. The rackmount banks are easily daisy-chained with DC plug-and-play connectors. Simply determine your application requirements and select one of these battery bank options.
-
Product
AC Load Bank (Resistive & Inductive)
K-1000 Resistive & Inductive
-
Kongter Test & Measurement Co., Limited
Kongter resistive & inductive AC load banks are used to simulate the motor loads or other electromagnetic devices working at their rated power factor. Many backup generators and turbines are rated at 0.7, 0.8 or 0.85 power factor and need to be commissioned at nameplate capacity using a combination of resistive and reactive load to fully qualify their operating capability. Using a resistive & reactive load bank enables comprehensive testing from a single unit.
-
Product
PXI 8 Banks of 8 Chan 1 Pole MUX
40-657-001-8/8/1
-
40-657 High Density Power Multiplexer Modules are available in a choice of configurations, containing up to 8 separate multiplexers, all 1-pole switching. They are suitable for switching signals to 110VDC/250VAC at 2Amps, 90W.
-
Product
AC Load Banks
K-1000 Series
-
Kongter Test & Measurement Co., Limited
Load bank testing is vital to replicate and verify the operation of critical backup power systems such as diesel generators and uninterruptible power supplies (UPS). Kongter offers a wide range of customer-tailored AC load banks that excel in a range of load test applications and environments.
-
Product
PXI MUX 8 Banks of 8 Channel Screened 1 Pole
40-610-021-S-8/8/1
-
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
Motive Power Load Banks
-
The only way to be certain that your stationary batteries will perform to specification is to test the batteries’ capacity with a DC load bank / portable battery discharge tester.
-
Product
PXI MUX 2 Banks of 32 Channel 1 Pole
40-610-021-2/32/1
-
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
SWITCHABLE FILTER BANKS
AFS-12WB
-
Matrix Test Equipment Incorporated
Models AFS-12WB contain banks of Matrix Model FLT-1 filters. Each filter may be individually selected. The Model AFS-12WB retains the manual operation in addition to remote control through the GPIB IEEE-488 interface. Optional internal Post Amplifier PA-20-20 with a gain of 0, 17 and 32dB @ +5dBm max..
-
Product
PXI 4 Banks of 16 Chan 1 Pole MUX
40-657-001-4/16/1
-
40-657 High Density Power Multiplexer Modules are available in a choice of configurations, containing up to 8 separate multiplexers, all 1-pole switching. They are suitable for switching signals to 110VDC/250VAC at 2Amps, 90W.
-
Product
AC Load Banks
XL300-400 Series
-
Mosebach Manufacturing Company
The XL300-400 Series of Load Banks offer 300 kW or 400 kW in various voltages in a compact, lightweight enclosure.
-
Product
PXI MUX 4 Banks of 32 Channel 1 Pole
40-610-022-4/32/1
-
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
PXI Solid State MUX, 2 bank, 80 channel
40-680-005
-
Based on FET switches, the multiplexers have no wear out mechanism and include fault protection that ensures the multiplexer automatically disconnects when PXI power is not applied. Available configurations for the 40-680 range vary from a single 160 to 1 MUX to a 20-bank, 8 to 1 MUX in a single PXI module.
-
Product
XR Resistive Reactive Load Banks
-
Mosebach Manufacturing Company
Mosebach’s XR series load bank offers you a range of options for resistive reactive loads in both lower voltages of 480 and 600 or MV at 4160 and higher. Outdoor rated user friendly for years of use.
-
Product
Radiator Mounted Load Banks
RD-Series
-
RD-series radiator mounted load banks are designed to be fitted directly onto diesel generator sets. RD-series load banks use the engine cooling air from the generator radiator to cool the load elements.
-
Product
Resistive Load Banks
R Series
-
Load banks are devices which contain resistive, inductive and/or capacitive loads, apply the load to an electrical power source and dissipate the power of the electrical source. Portable and stationary resistive load banks incorporate as low as 1 kW load step increments for testing small to large generating sets. The fine control resolution ensures accurate load control and power factor targeting adjustments.
-
Product
Preselectors and Switch Filter Banks
-
Our preselectors and switch filter banks offer low noise figure, high dynamic range, state-of-the-art filter rejection with high channel-to-channel isolation front ends, realized in compact building blocks, designed in custom form factors. Applicable markets include: EW, missiles, radar, communications and space.
-
Product
AC Load Bank (Resistive/Capacitive)
K-1000 Resistive/Capacitive
-
Kongter Test & Measurement Co., Limited
A RCD (resistive/capacitive) generator load bank is non-linear load bank. The electronic and non-linear loads simulated by capacitive load banks are typical of the Telecommunications, Computer or Uninterruptible Power Supply (UPS) Industries.
-
Product
LXI Single Bank, 12:1 MUX 75 Ohm 1GHz F-type
60-722-001
-
Our 60-722 High Isolation RF Multiplexer is suitable for switching 75Ω signals up to 1GHz. With the choice of single or dual multiplexer banks each with 12 channels, it is ideal for constructing complex microwave switching systems for many applications.
-
Product
Load Banks
PARELO
-
Amfax introduce the latest generation of load banks we affectionately call PARELO. This range of load banks provides a combination of high performance passive resistive loads along with extreme flexibility of use. This is achieved by our unique FLEXI-phase Switching(TM) technology.. Designed primarily for offering high wattage loads for the aerospace, energy, automotive and transport sectors. PARELO load banks are a cost effective solution for companies requiring high wattage loads when testing their products.
-
Product
Load Banks
-
Power Test Dynamometer offers a complete high capacity load testing solution with our load bank and gen set testing systems. Capable of testing generators and AC/DC power sources, our load bank systems safely apply electrical loads across the entire spectrum of operation. By offering a one-stop-shop for your Load Bank and it's accompanying data acquisition software, Power Test is committed to Making Your Testing Easy.
-
Product
Banking And Insurance
-
Banking applications can be complex. They have to support thousands of concurrent users without having to compromise on the functionalities. Banks need to have a robust infrastructure and should be seamlessly integrated into the backend systems.
-
Product
DC Load Banks
-
Eagle Eye Power Solutions’ SLB-Series DC Load Testers are designed for ease of use, portability, and versatility in mind. Discharge testing batteries is the only verifiable method the capacity of your batteries and the SLB delivers a programmable, constant current load for your testing needs. Whether you are load testing for capacity, performance, acceptance, NERC compliance, or other, the SLB provides an economical complete package solution. Increase employee and battery system safety with per cell monitoring and standard built in auto-shutdown features. To suit a variety of industries and diverse applications, Eagle Eye Power Solutions offers over 75 standard models to fit your exact needs at the best price.
-
Product
AC Load Bank (Resistive)
K-1000 Resisitive
-
Kongter Test & Measurement Co., Limited
The kW of a resistive load bank is “real” power in electrical terms. When a resistive AC load bank is used to test an engine generator set the engine will produce its full horsepower rating, dissipate engine exhaust gases, and produce thermal energy into the engine cooling system. The resistive load bank in fact, will completely test the engine and its various systems.
-
Product
PXI MUX 2 Banks of 64 Channel 1 Pole
40-610-022-2/64/1
-
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer


























